LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
1
LC1-D0910ii
LC1-D2510ii
LC1-D9511ii
Te1/18
Contactors
d 3-pole contactors for motor control, 9 to 95 A
Utilisation category AC-3
Control circuit : a.c.
References
c
Standard power ratings
Rated
of 3-phase motors
operational
50/60 Hz in category AC-3
current
(θ ≤ 55 °C)
in AC-3
up to
220V 380V
660V 440V
230V 400V 415V 440V 500V 690V
kW kW kW kW kW kW
A
2.2 4 4 4 5.5 5.5
9
3 5.5 5.5 5.5 7.5 7.5
12
4 7.5 9 9 10 10
18
5.5 11 11 11 15 15
25
7.5 15
15
15
18.5 18.5
http://www.DataSheet4U.net/
32
11 18.5 22 22 22 30
40
Instantaneous Basic reference.
auxiliary
Complete with code
contacts
indicating control
circuit voltage (2)
Fixing,
cabling (1)
Weight
kg
––
LC1-D0900ii (3)
0.320
1–
LC1-D0910ii
0.320
–1
LC1-D0901ii
0.320
––
LC1-D1200ii (3)
0.320
1–
LC1-D1210ii
0.320
–1
LC1-D1201ii
0.320
––
LC1-D1800ii (3)
0.320
1–
LC1-D1810ii
0.350
–1
LC1-D1801ii
0.350
––
LC1-D2500ii (3)
0.320
1–
LC1-D2510ii
0.505
–1
LC1-D2501ii
0.505
––
LC1-D3200ii (3)
0.320
1–
LC1-D3210ii
0.525
–1
LC1-D3201ii
0.525
11
LC1-D4011ii
1.150
15 22 25 30 30 33
50
11
LC1-D5011ii
1.150
18.5 30 37 37 37 37
65
11
LC1-D6511ii
1.150
22 37 45 45 55 45
80
11
LC1-D8011ii
1.500
25 45 45 45 55 45
95 (4)
11
LC1-D9511ii
Note : Add-on auxiliary contact blocks and modules : see pages 1/32 to 1/43.
1.500
(1) For LC1-D09 to D32 : clip-on mounting onto 35 mm " rail AM1-DP.
For LC1-D40 to D95 : clip-on mounting onto 35 mm or 75 mm " rail AM1-DL.
Power terminals : LC1-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals.
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660
50 Hz
B5 D5 E5 F5 M5
P5 U5 Q5
V5 N5 R5 S5 Y5
60 Hz
B6 D6 E6 F6 M6
– U6 Q6
– – R6 – –
50/60 Hz B7 D7 E7 F7 M7
P7 U7 Q7
V7 N7 R7 – –
(3) 3-pole contactors without auxiliary contact (standard EN 50012).
(4) 95 A rated operational current in AC-3 up to 400 V.
Other versions
Contactors with non-protected power terminals enabling “power” and “control”
connections to be made using ring type terminals.
Please consult your Regional customer centre.
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
LP1-D0910ii
LP1-D3210ii
Contactors
d 3-pole contactors for motor control, 9 to 80 A
Utilisation category AC-3
Control circuit : d.c.
References
a
Standard power ratings
of 3-phase motors
50/60 Hz in category AC-3
(θ ≤ 55 °C)
220V 380V
660V
230V 400V 415V 440V 500V 690V
kW kW kW kW kW kW
2.2 4 4 4 5.5 5.5
Rated
operational
current
in AC-3
up to
440V
A
9
Instantaneous Basic reference.
auxiliary
Complete with code
contacts
indicating control
circuit voltage (2)
Fixing,
cabling (1)
Weight
kg
1–
LP1-D0910ii
0.580
1
–1
LP1-D0901ii
0.580
3 5.5 5.5 5.5 7.5 7.5
12
1–
LP1-D1210ii
0.580
–1
LP1-D1201ii
0.580
4 7.5 9 9 10 10
18
1–
LP1-D1810ii
0.600
–1
LP1-D1801ii
0.600
5.5 11 11 11 15 15
25
1–
LP1-D2510ii
0.850
–1
LP1-D2501ii
0.850
7.5 15
15
15
18.5 18.5
http://www.DataSheet4U.net/
32
1–
–1
LP1-D3210ii
LP1-D3201ii
0.880
0.880
11 18.5 22 22 22 30
40
11
LP1-D4011ii
2.100
15 22 25 30 30 33
50
11
LP1-D5011ii
2.120
18.5 30 37 37 37 37
65
11
LP1-D6511ii
2.160
22 37 45 45 55 45
80
11
LP1-D8011ii
Note : Add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43.
2.220
(1) For LP1-D09 to D25 : clip-on mounting on 35 mm " rail AM1-DP.
For LP1-D40 to D80 : clip-on mounting on 75 mm " rail AM1-DL.
Power terminals : LP1-D09 to D80 protected against direct finger contact. Ready-to-tighten terminals.
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts a
12 24 36 48 60 72 110 125 220 250 440
U 0.8…1.1 Uc (3) JD BD CD ED ND SD FD GD MD UD RD
U 0.7…1.25 Uc (4) JW BW CW EW – SW FW –
MW –
(3) LP1-D40 to D80 : 0.85…1.1 Uc.
(4) LP1-D40 to D80 : 0.75…1.2 Uc.
Other versions
Contactors with non-protected power terminals enabling “power” and “control”
connections to be made using ring type terminals.
Please consult your Regional customer centre.
Te
1/19
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
1
LC1-D0910ii
LC1-D12004ii
LC1-D65004ii
Te1/20
Contactors
d 3 and 4-pole contactors for heating, lighting, etc., 25 to 125 A
Utilisation category AC-1
Control circuit : a.c.
References
Non inductive loads
Maximum operational
current
Utilisation category AC-1
(θ ≤ 55 °C)
Number
of poles
Instantaneous
auxiliary
contacts
Basic reference.
Complete with code
indicating control
circuit voltage (2)
Fixing,
cabling (1)
Weight
A
N/O N/C
kg
25
3
––
LC1-D0900ii
0.320
––
or LC1-D1200ii (3)
0.320
1–
LC1-D0910ii
0.320
1–
or LC1-D1210ii (3)
0.320
–1
LC1-D0901ii
0.320
–1
or LC1-D1201ii (3)
0.320
4
––
LC1-D12004ii
0.320
22
––
LC1-D12008ii
0.320
32
3
––
LC1-D1800ii
0.320
1–
LC1-D1810ii
0.350
–1
LC1-D1801ii
0.350
40
3
––
LC1-D2500ii
0.320
http://www.DataSheet4U.net/
1–
–1
LC1-D2510ii
LC1-D2501ii
0.505
0.505
4
––
LC1-D25004ii
0.505
22
––
LC1-D25008ii
0.505
50
3
––
LC1-D3200ii
0.320
1–
LC1-D3210ii
0.525
–1
LC1-D3201ii
0.525
60
3
11
LC1-D4011ii
1.150
4
––
LC1-D40004ii
1.150
22
––
LC1-D40008ii
1.150
80
3
11
LC1-D5011ii
1.150
11
or LC1-D6511ii (3)
1.150
4
––
LC1-D65004ii
1.150
22
––
LC1-D65008ii
1.150
125
3
11
LC1-D8011ii
1.500
11
or LC1-D9511ii (3)
1.500
4
––
LC1-D80004ii
1.530
22
––
LC1-D80008ii
1.530
Note : Add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43.
(1) For LC1-D09 to D32 : clip-on mounting on 35 mm " rail AM1-DP.
For LC1-D40 to D95 : clip-on mounting on 35 mm or 75 mm " rail AM1-DL.
Power terminals : LC1-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals.
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660
50 Hz
B5 D5 E5 F5 M5
P5 U5 Q5
V5 N5 R5 S5 Y5
60 Hz
B6 D6 E6 F6 M6
– U6 Q6
– – R6 – –
50/60 Hz B7 D7 E7 F7 M7
P7 U7 Q7
V7 N7 R7 – –
(3) Selection according to number of operating cycles.
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
LP1-D0910ii
LP1-D3210ii
Contactors
d 3 and 4-pole contactors for heating, lighting, etc., 25 to 125 A
Utilisation category AC-1
Control circuit : d.c.
References
Non inductive loads
Maximum operational
current
Utilisation category AC-1
(θ ≤ 55 °C)
Number
of poles
Instantaneous
auxiliary
contacts
Basic reference.
Complete with code
indicating control
circuit voltage (2)
Fixing,
cabling (1)
Weight
A
N/O N/C
kg
25
3
1–
LP1-D0910ii
0.580
1–
or LP1-D1210ii (5)
0.580
–1
LP1-D0901ii
0.580
–1
or LP1-D1201ii (5)
0.580
4
––
LP1-D12004ii
0.580
22
––
LP1-D12008ii
0.580
32
3
1–
LP1-D1810ii
0.600
–1
LP1-D1801ii
0.600
40
3
1–
LP1-D2510ii
0.850
–1
LP1-D2501ii
0.850
4
––
LP1-D25004ii
0.850
22
––
LP1-D25008ii
0.850
50
http://www.DataSheet4U.net/
3
1–
LP1-D3210ii
0.880
–1
LP1-D3201ii
0.880
60
3
11
LP1-D4011ii
2.100
4
––
LP1-D40004ii
2.100
22
––
LP1-D40008ii
2.100
80
3
11
LP1-D5011ii
2.120
11
or LP1-D6511ii (5)
2.160
4
––
LP1-D65004ii
2.180
22
––
LP1-D65008ii
2.180
125
3
11
LP1-D8011ii
2.220
4
––
LP1-D80004ii
2.250
22
––
LP1-D80008ii
Note : Add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43.
2.250
1
(1) For LP1-D12 to D32 : clip-on mounting on 35 mm " rail AM1-DP.
For LP1-D40 to D80 : clip-on mounting on 75 mm " rail AM1-DL.
Power terminals : LP1-D12 to D80 protected against direct finger contact. Ready-to-tighten terminals.
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts a
12 24 36 48 60 72 110 125 220 250 440
U 0.8…1.1 Uc (3) JD BD CD ED ND SD FD GD MD UD RD
U 0.7…1.25 Uc (4) JW BW CW EW – SW FW –
MW –
(3) For LP1-D40 to D80 : 0.85…1.1 Uc.
(4) For LP1-D40 to D80 : 0.75…1.2 Uc.
(5) Selection according to number of operating cycles.
Te
1/21
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
1
LC2-D1201ii
LP2-D0901ii
Te1/22
Contactors
d 3-pole reversing contactors for motor control,
assembled by Telemecanique
9 to 95 A (a.c. control circuit) and
9 to 32 A (d.c. control circuit). Utilisation category AC-3
References
3-pole reversing contactors horizontally mounted (1)
c
aor
a.c. control circuit
Standard power ratings
of 3-phase motors
50/60 Hz in category AC-3
Rated
operational
current
in AC-3
up to
440V
Instantaneous Basic reference.
auxiliary
Complete with code
contacts
indicating control
per circuit voltage (2)
contactor Fixing,
cabling (3)
Weight
220V 380V
660V
230V 400V 415V 440V 500V 690V
kW kW kW kW kW kW
A
N/O N/C
kg
2.2 4 4 4 5.5 5.5
9
–1
LC2-D0901i i
0.700
3 5.5 5.5 5.5 7.5 7.5
12
–1
LC2-D1201i i
0.700
4 7.5 9 9 10 10
18
–1
LC2-D1801i i
0.750
5.5 11 11 11 15 15
25
–1
LC2-D2501i i
1.100
7.5 15 15 15 18.5 18.5 32
–1
LC2-D3201i i
1.200
11 18.5 22 22 22 30
40
11
LC2-D4011i i
2.400
15 22 25 30 30 33
50
11
LC2-D5011i i
2.400
18.5 30 37 37 37 37
65
11
LC2-D6511i i
2.400
22 37 45 45 55 45
80
11
LC2-D8011i i
3.200
25
45
45
45
55 45
http://www.DataSheet4U.net/
d.c. control circuit
Standard power ratings
of 3-phase motors
50/60 Hz in category AC-3
95 (up to 400V) 1 1
LC2-D9511i i
3.200
Rated
operational
current
in AC-3
up to
440V
Instantaneous Basic reference.
auxiliary
Complete with code
contacts
indicating control
per circuit voltage (4)
contactor Fixing,
cabling (5)
Weight
220V 380V
660V
230V 400V 415V 440V 500V 690V
kW kW kW kW kW kW
A
N/O N/C
kg
2.2 4 4 4 5.5 5.5
9
–1
LP2-D0901i i
1.200
3 5.5 5.5 5.5 7.5 7.5
12
–1
LP2-D1201i i
1.200
4 7.5 9 9 10 10
18
–1
LP2-D1801i i
1.270
5.5 11 11 11 15 15
25
–1
LP2-D2501i i
1.750
7.5 15 15 15 18.5 18.5 32
Accessories (to be ordered separately)
–1
LP2-D3201i i
1.850
Auxiliary contact blocks and add-on modules, see pages 1/32 to 1/43.
(1) Fitted with pre-wired power circuit connections and mechanical interlock, without electrical interlocking.
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660
50 Hz
B5 D5 E5 F5 M5
P5 U5 Q5
V5 N5 R5 S5 Y5
60 Hz
B6 D6 E6 F6 M6
– U6 Q6
– – R6 – –
50/60 Hz B7 D7 E7 F7 M7
P7 U7 Q7
V7 N7 R7 – –
(3) For LC2-D09 to D32 : clip-on mounting on 35 mm " rail or screw fixing.
For LC2-D40 to D95 : clip-on mounting on 35 mm or 75 mm " rail or screw fixing.
Power terminals protected against direct finger contact and ready-to-tighten terminals.
(4) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Uc (Volts) a
12 24 36 48 60 72 110 125 220 250 440
U 0.8 to 1.1 Uc
standard coils
JD BD CD ED ND SD FD GD MD UD RD
U 0.7 to 1.25 Uc wide range coils JW BW CW EW – SW FW – MW – –
(5) Clip-on mounting on 35 mm " rail or screw fixing.
Power terminals protected against direct finger contact. Ready-to-tighten terminals.
Other versions Reversing contactors fitted with mechanical interlock, with integral electrical interlocking.
Please consult your Regional customer centre.
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Dimensions, mounting :
pages 1/44 to 1/48
LC2-D12004ii
Contactors
d 4-pole changeover contactors for distribution circuits,
assembled by Telemecanique
25 to 125 A (a.c. control circuit) and
25 and 40 A (d.c. control circuit). Utilisation category AC-1
References
4-pole changeover contactors, horizontally mounted (1)
c
aor
a.c. control circuit
Non inductive loads
Maximum rated
operational current
Utilisation category AC-1
(θ < 55 °C)
Instantaneous
auxiliary
contacts
per
contactor
Basic reference.
Complete with code
indicating control
circuit voltage
Fixing,
cabling (3)
Weight
1
A N/O N/C
25
––
LC2-D12004ii
40
––
LC2-D25004ii
60
––
LC2-D40004ii
80
––
LC2-D65004ii
125
––
LC2-D80004ii
4-pole changeover contactors, horizontally mounted (1)
kg
0.700
1.100
2.400
3.200
3.200
d.c. control circuit
Non inductive loads
Maximum rated
operational current
Utilisation category AC-1
(θ < 55 °C)
http://www.DataSheet4U.net/
Instantaneous
auxiliary
contacts
per
contactor
Basic reference.
Complete with code
indicating control
circuit voltage
Fixing,
cabling (5)
Weight
A N/O N/C
25 – –
40 – –
Accessories (to be ordered separately)
LP2-D12004ii
LP2-D25004ii
kg
1.200
1.750
Auxiliary contact blocks and add-on modules, see pages 1/32 to 1/43.
(1) Fitted with pre-wired power circuit connections and mechanical interlock, without electrical interlocking.
Order separately 2 auxiliary contact blocks LA1-DNi1 to obtain electrical interlocking between the 2
contactors (see pages 1/33 to 1/37).
(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660
50 Hz
B5 D5 E5 F5 M5
P5 U5 Q5
V5 N5 R5 S5 Y5
60 Hz
B6 D6 E6 F6 M6
– U6 Q6
– – R6 – –
50/60 Hz B7 D7 E7 F7 M7
P7 U7 Q7
V7 N7 R7 – –
(3) For LC2-D12 and D25 : clip-on mounting on 35 mm " rail or screw fixing.
For LC2-D40 to D80 : clip-on mounting on 35 mm or 75 mm " rail or screw fixing.
Power terminals protected against direct finger contact. Ready-to-tighten terminals.
(4) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Uc (Volts) a
12 24 36 48 60 72 110 125 220 250 440
U 0.8 to 1.1 Uc
standard coils
JD BD CD ED ND SD FD GD MD UD RD
U 0.7 to 1.25 Uc wide range coils JW BW CW EW – SW FW – MW – –
For other voltages, please consult your customer centre.
(5) Clip-on mounting on 35 mm " rail or screw fixing.
Power terminals protected against direct finger contact. Ready-to-tighten terminals.
Other versions Reversing contactors fitted with mechanical interlock, with integral electrical interlocking.
Please consult your Regional customer centre.
Te
1/23
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Contactors
d 3 and 4-pole contactors
Components for assembling reversing contactors and
changeover contactor pairs (horizontally mounted), for customer assembly
Combinations
Contactors Mechanical interlocks Set of power connections
Assembled
Without
1 using 2 identical electrical interlocking
contactors
horizontally
mounted,
type :
With integral
electrical interlocking
(2 N/C contacts)
3-pole reversing contactors
4-pole changeover
contactor pairs
LC1-D09
LC1-D12
LC1-D18
LC1-D25
LC1-D32
LP1-D09
LP1-D12
LP1-D18
LP1-D25
LP1-D32
LA9-D09978
LA9-D0902
LA9-D1269
LA9-D1869
LA9-D2569
LA9-D3269
LA9-D1270
LA9-D2570
LC1-D40
LC1-D50
LC1-D65
LP1-D40
LP1-D50
LP1-D65
LA9-D50978
LC1-D80
LC1-D95
LA9-D4002
http://www.DataSheet4U.net/
LA9-D6569
LA9-D8069
LA9-D6570
LA9-D8070
LP1-D80
LA9-D80978
LA9-D8002
LA9-D8069
LA9-D8070
Te1/24
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/24
Contactors
d 3 and 4-pole contactors
Components for assembling reversing contactors and
changeover contactor pairs (horizontally mounted),
for customer assembly
References
c
aor
Component parts (including mechanical interlock with integral electrical interlocking)
With
2 identical
contactors (1)
Set of power connections
Reference
Weight
kg
Mechanical interlock
Kit reference
Weight
kg
For assembly of 3-pole reversing contactors for motor control
LC1/LP1-D09iiii
LC1/LP1-D12iiii
LA9-D1269
0.015
LA9-D0902
0.060
LC1/LP1-D18iiii LA9-D1869
0.030
LA9-D0902
0.060
LC1/LP1-D25iiii LA9-D2569
0.030
LA9-D0902
0.060
LC1/LP1-D32iiii LA9-D3269
0.040
LA9-D0902
0.060
LC1/LP1-D4011ii
LC1/LP1-D5011ii
LC1/LP1-D6511ii
LA9-D6569
0.290
LA9-D4002
0.170
LC1-D8011ii
LA9-D8069
0.490
LA9-D4002
0.170
LP1-D8011ii
LA9-D8069
0.490
LA9-D8002
0.170
LC1-D9511ii
LA9-D8069
0.490
LA9-D4002
0.170
For assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system)
LC1/LP1-D12004ii LA9-D1270
0.010
LA9-D0902
0.060
LC1/LP1-D25004ii LA9-D2570
0.020
LA9-D0902
0.060
LC1/LP1-D40004ii
LC1/LP1-D65004ii
LA9-D6570
http://www.DataSheet4U.net/
0.150
LA9-D4002
0.170
LC1-D80004ii
LA9-D8070
0.280
LA9-D4002
0.170
LP1-D80004ii
LA9-D8070
0.280
LA9-D8002
Component parts (including mechanical interlock, without electrical interlocking)
0.170
1
For assembly of 3-pole reversing contactors for motor control
LC1/LP1-D0901ii
LC1/LP1-D1201ii
LA9-D1269
0.015
LA9-D09978
0.030
LC1/LP1-D1801ii LA9-D1869
0.030
LA9-D09978
0.030
LC1/LP1-D2501ii LA9-D2569
0.030
LA9-D09978
0.030
LC1/LP1-D3201ii LA9-D3269
0.040
LA9-D09978
0.030
LC1/LP1-D4011ii
LC1/LP1-D5011ii
LC1/LP1-D6511ii
LA9-D6569
0.290
LA9-D50978
0.155
LC1-D8011ii
LA9-D8069
0.490
LA9-D50978
0.155
LP1-D8011ii
LA9-D8069
0.490
LA9-D80978
0.180
LC1-D9511ii
LA9-D8069
0.490
LA9-D50978
0.155
For assembly of 4-pole changeover contactor pairs for distribution(3-phase + neutral distribution system) (2)
LC1/LP1-D12004ii LA9-D1270
0.010
LA9-D09978
0.030
LC1/LP1-D25004ii LA9-D2570
0.020
LA9-D09978
0.030
LC1/LP1-D40004ii LA9-D6570
LC1/LP1-D65004ii
0.150
LA9-D50978
0.155
LC1-D80004ii
LA9-D8070
0.280
LA9-D50978
0.155
LP1-D80004ii
LA9-D8070
0.280
LA9-D80978
(1) To order the 2 contactors : see pages 1/18 to 1/21.
(2) Order 2 contact blocks LA1-DNi1 to obtain electrical interlocking. See pages 1/33 to 1/37.
Te
0.180
1/25
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LR2-D13ii
LR2-D23ii
LR2-D33ii
Thermal overload relays
d 3-pole thermal overload relays (class 10 A)
adjustable from 0.1 to 93 A, for motor protection
References
Thermal overload relays to be used with fuses
Thermal overload relays
- compensated with manual or automatic reset,
- relay trip indicator,
- for a.c. or d.c.
Relay
Fuses to be used
For direct
setting
with selected relay
mounting
range
Type
beneath contactor
aM gG (BS88) LC1, LP1
AA
A
Reference
Class 10 A (1)
0.10…0.16
0.16…0.25
0.25…0.40
0.40…0.63
0.63…1
1…1.6
1.6…2.5
2.5…4
4…6
5.5…8
7…10
9…13
12…18
17…25
23…32
30...40
17…25
23…32
30…40
37…50
48…65
55…70
63…80
80…93
0.25
0.5
1
1
2
2
4
6
8
12
12
16
20
25
40
40
25
40
40
63
63
80
80
100
http://www.DataSheet4U.net/
2
2
2
4
4
6
10
16
16
20
20
25
32
50
63
80
50
63
80
100
100
125
125
160
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D09…D32
D12…D32
D18…D32
D25 and D32
D25 and D32
D32
D40…D95
D40…D95
D40…D95
D50…D95
D50…D95
D65…D95
D80 and D95
D95
LR2-D1301
LR2-D1302
LR2-D1303
LR2-D1304
LR2-D1305
LR2-D1306
LR2-D1307
LR2-D1308
LR2-D1310
LR2-D1312
LR2-D1314
LR2-D1316
LR2-D1321
LR2-D1322
LR2-D2353
LR2-D2355
LR2-D3322
LR2-D3353
LR2-D3355
LR2-D3357
LR2-D3359
LR2-D3361
LR2-D3363
LR2-D3365
3-pole thermal overload relays for use with unbalanced loads
Weight
kg
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.165
0.320
0.320
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
Class 10 A : Change the prefix in the references above from LR2 to LR3. Example : LR3-D1301.
(1) Standard IEC 947-4 specifies a tripping time for 7.2 times the setting current IR :
class 10 A : between 2 and 10 seconds.
Other versions
Thermal overload relays
- for distribution circuits,
- with flat terminals for ring type connectors (except LR2-D3365).
Please consult your Regional customer centre.
LR2, LR3-D1
Independent mounting on 50 mm centres
or on rail AM1-DP200 or DE200
LA7-D1064
45
= 35 =
Independent mounting on 110 mm centres
46
LA7-D1064
==
98 d
2xØ4,5 8
17
AM1-DP200
d2
(1) + 5 mm for LR2-D15ii
Te1/26
AM1-DE200
9.5
108 DX1-AP25 2xØ6,5
Remote trip or electrical reset
LA7-D03 (1)
96 34
(1) Can be mounted on RH or LH
side of relays LR2, LR3-D1
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Thermal overload relays
d 3-pole thermal overload relays (class 20)
adjustable from 0.1 to 93 A, for motor protection
References
LR2-D15i i
LR2-D25i i
LR2-D35i i
Thermal overload relays to be used with fuses
Thermal overload relays
- compensated with manual or automatic reset,
- relay trip indicator,
- for a.c. or d.c.
Relay
Fuses to be used
setting
with selected relay
range
Type
aM gG (BS88)
AA
A
For direct
mounting
beneath contactor
LC1, LP1
Reference
Class 20 (1)
2.5…4
6
16 D09…D32
LR2-D1508
4…6
8
16 D09…D32
LR2-D1510
5.5…8
12
20 D09…D32
LR2-D1512
7…10
16
25 D09…D32
LR2-D1514
9…13
16
25 D12…D32
LR2-D1516
12…18
25
40 D18…D32
LR2-D1521
17…25
32
50 D25 and D32
LR2-D1522
23…32
40
63 D25 and D32
LR2-D2553
17…25
32
50 D40…D95
LR2-D3522
23…32
40
63 D40…D95
LR2-D3553
30…40
50
80 D40…D95
LR2-D3555
37…50
63
100 D50…D95
LR2-D3557
48…65
80
100 D50…D95
LR2-D3559
55…70
100
125 D65…D95
LR2-D3561
63…80
100
125 D80 and D95
LR2-D3563
(1) Standard IEC 947-4 specifies a tripping time for 7.2 times the setting current IR :
class 20 : between 6 and 20 seconds.
Other versions
http://www.DataSheet4U.net/
Thermal overload relays
- for distribution circuits,
- with flat terminals for ring type connectors.
Please consult your Regional customer centre.
1
Weight
kg
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.345
0.535
0.535
0.535
0.535
0.535
0.535
0.535
LR2, LR3-D2
Independent mounting on 50 mm centres
or on rail AM1-DP200 or DE200
LA7-D2064
55
= 40
=
Independent mounting on 110 mm centres
57
LA7-D2064
==
Remote trip or electrical reset device
LA7-D03 (1)
98 d
AM1-DP200
d2
2xØ4,5 13
22
AM1-DE200
9.5
LR2, LR3-D3
Independent mounting on 50 mm centres
or on rail AM1-DP200 or DE200
75
LA7-D3064
= 50
=
108 DX1-AP26 2xØ6,5
Independent mounting on 110 mm centres
LA7-D3064
LA7-D902
75
==
121 d 2xØ4,5
23,5
32
AM1-DP200
d2
AM1-DE200
9.5
3xØ6,5
131 = 40 =
96 29
(1) Can be mounted on RH or LH
side of relays LR2, LR3-D2
Remote trip or electrical reset device
LA7-D03 (1)
119 21
(1) Can be mounted on RH or LH side
of relays LR2-D, LR3-D3
Te
1/27
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
DX1-AP25
LA7-D1064
LR2-D
LA7-D305
LA7-D03
DX1-AP26
LR2-D1
LR3-D1
LA7-D03
LA7-D2064 LA7-D901
http://www.DataSheet4U.net/
R
LR2-D2
LR3-D2
LA7-D3064
LR2-D
LA7-D1020
ZA2-BZ13
ZA2-BL432
LA7-D902
LA7-D1020
ZA2-BZ13
Te1/28
LR2-D3
LR3-D3
ZA2-BA639
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/28
LA7-D1020
Adaptor for door mounted operator
c 10
Stop
Thermal overload relays
d 3-pole thermal overload relays
adjustable from 0.1 to 93 A
References
Accessories (to be ordered separately)
Description
Terminal blocks (1)
for clip-on mounting on
35 mm rail (AM1-DP200)
or screw fixing.
See pages 1/26 and 1/27
for fixing centres
Power terminals adaptor
for mounting an LRi-D13
overload relay beneath an
LC1-D40, D50 or D65 contactor
Mounting plates (3)
for screw fixing
on 110 mm centres
Marker holder
snap-in
Bag of 400 labels
(blank, self-adhesive) 7 x 16 mm
Locking device
for “Stop” button
Remote tripping and
electrical reset device (4)
Remote control
For use on
overload relays
LR2-D1
LR3-D1
LR2-D2
LR3-D2
LR2-D3
LR3-D3
LR2-D1
LR3-D1
Sold in
lots of
1
1
1
1
LR2-D1
LR3-D1
LR2-D2
LR3-D2
LR2-D3
LR3-D3
LR2-D
LR3-D
LR2-D
LR3-D
LR2-D
LR3-D
10
10
1
100
1
10
1
Unit
reference
LA7-D1064
LA7-D2064
LA7-D3064 (2)
LA7-D1058
DX1-AP25
DX1-AP26
LA7-D902
LA7-D903
LA9-D91
LA7-D901
LA7-D03i (5)
Weight
kg
0.100
0.120
0.205
0.080
1
0.065
0.082
0.130
0.001
0.001
0.005
0.090
“Reset” function
By flexible cable
(length = 0.5 m)
http://www.DataSheet4U.net/
LR2-D
LR3-D
1
LA7-D305
0.075
“Stop” and/or “Reset” function
For fitting, remove the terminal protection shrouds and order the following 3 products :
Adaptor
LR2-D
1
LA7-D1020
0.005
for door mounted operator
LR3-D
Rod (snap-off end to obtain required LR2-D 10 ZA2-BZ13
0.100
length between 17 and 120 mm)
LR3-D
Operating head
LR2-D
1
ZA2-Biiii (6)
0.012
for spring return pushbutton
LR3-D
(1) Terminal blocks are supplied with terminals protected against direct finger contact. Ready-to-tighten
screws.
(2) With terminals for ring type connectors, the reference becomes LA7-D30646.
(3) Remember to order the terminal block corresponding to the overload relay size.
(4) The time for which the coil of remote tripping and electrical resetting device LA7-D03 can remain
energised depends on its rest time : 1 s pulse duration with 9 s rest time ; 5 s pulse duration with 30 s rest
time ; 10 s pulse duration with 90 s rest time ; maximum pulse duration of 20 s with a rest time of 300 s.
Minimum impulse time : 200 ms.
(5) Reference to be completed by adding the coil voltage code.
Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c
12
24
48
96
110 220/230 380/400 415/440
50/60 Hz
B
E
F
MQN
Consumption, inrush and sealed : < 100 VA
Volts a
J
B
E
DD F
M–
Consumption, inrush and sealed : < 100 W.
(6) Reference to be completed, please refer to chapter 5.
Reset
LA7-D305
“Reset” by flexible cable
Mounting with cable straight
LA7-D305
Mounting with cable bent
LA7-D1020
c : adjustable from 17 to 120 mm
ec
c : up to 550 mm
e : up to 20 mm
e M10x1
e : up to 20 mm
Te
1/29
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
pages 1/26 to 1/29
Scheme
LR2-D
LR3-D
1
{RESET Auto.
Man.
TEST
STOP
Thermal overload relays
d 3-pole thermal overload relays
adjustable from 0.1 to 93 A
Scheme, setting-up
Setting-up the special functions of LR2-D and LR3-D thermal overload relays
Setting the relay
“Manual-Automatic” selection 4
7
2 5,5
LR2 D 13
5
1
8A
MU
6
T
O
4
TEST
STOP RESET
3
RESET
A
U
T
O
NO
98 97
NC
95 96
“Manual” reset
A
U
T
O
RESET
“Automatic” reset
i Lift the transparent cover 1 to gain access to the settings and controls.
i Adjustment is achieved by turning dial 2 which is graduated directly in
Amperes.
i The setting can be locked by sealing 3 of the cover.
i After having lifted the transparent cover, the type of reset operation can be
http://www.DataSheet4U.net/
selected by turning the blue “RESET” selector 4 :
- turn to the left for manual reset,
- push and turn to the right for automatic reset.
The selector is then held in the automatic position and is released by turning
the selector to the left (return to manual operation).
i With the cover folded down, the selector is locked.
i Manual resetting of the relay is achieved by pressing the blue “RESET”
button.
“Stop” function 5
“Test” function 6
STOP
A
U
T
O
ET
A
U
T
O
RESET
Stop
Locking
i The “Stop” function is obtained by pressing the red “STOP” button 5.
i Pressing the “STOP” button :
- actuates the N/C contact,
- does not affect the N/O contact.
i The “STOP” button can be locked by fitting a “U” clip (ref. LA7-D901).
With the cover folded down, the device is locked.
TEST
Test Trip indicator
i The “Test” function is obtained by pressing the red “TEST” button 6 with a
screwdriver.
i Operation of the “TEST” button simulates tripping of the relay and :
- actuates both N/O and N/C contacts,
- actuates the trip indicator 7.
Te1/30
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
pages 1/26 and 1/27
LR2, LR3-D1
Direct mounting beneath contactors
LC1-D09 to D32, LP1-D09 to D32 and LP4-D12
Thermal overload relays
d 3-pole thermal overload relays
adjustable from 0.1 to 93 A
Dimensions
92
cd
8
17
44 g
LR2, LR3-D2
Direct mounting beneath contactors
LC1-D25 and D32, LP1-D25 and D32
AM1-DP200
AM1-DE200
d2
9.5
LC1-D09, D12, D18
LC1-D25
LC1-D32
LP1-D09, D12, D18
LP1-D25
LP1-D32
LP4-D12
b (1)
81
86
86
81
86
86
81
(1) + 5 mm for LR2-D15ii
c
98
108
109
133
152
153
98
e
50
55
55
50
55
55
50
g
0
10.7
8.1
0
10.7
8.1
0
1
92
cd
13
22
54 g
LR2, LR3-D3
Direct mounting beneath contactors
LC1-D40 to D95 and LP1-D40 to D80
http://www.DataSheet4U.net/
AM1-DP200
d2
LC1-D25
LC1-D32
LP1-D25
LP1-D32
AM1-DE200
9.5
bc
97.5 98
97.5 98
97.5 155
97.5 155
e
60
60
60
60
g
1.5
0.5
1.5
0.5
109
4c
d
21
30
70 g
AM1-DL201
d7
LC1-D40
LC1-D50
LC1-D65
LC1-D80
LC1-D95
LP1-D40
LP1-D50
LP1-D65
LP1-D80
AM1-DL200
17
b
111
111
111
115.5
115.5
111
111
111
115.5
c
119
119
119
124
124
176
176
176
179.4
e
72.4
72.4
72.4
76.9
76.9
72.4
72.4
72.4
76.9
g (3P) g (4P)
4.5 13
4.5 –
4.5 13
9.5 22
9.5 –
4.5 13
4.5 –
4.5 13
9.5 22
Te
1/31
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LA8-DN
LC1-D09, D12, D18
LA8-DN
LA1-DN10, DN01
LC1-D25, D32
http://www.DataSheet4U.net/
LA6-DK
LA1-DN
LA1-DN, DC
LC1-D40, D50, D65, D80, D95
LA2-DT, DS
LA3-DR
Te1/32
LA1-DX, DY, DZ
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/32
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Auxiliary contact blocks and accessories
Control circuit : a.c.
References
Instantaneous auxiliary contact blocks (1)
For use in normal operating environments
Number Max. number of blocks per contactor
of Clip-on mounting
contacts Front
Side
Composition
Reference
Weight
kg
1 1 (D25 and D32) –
or 2 (D40…D95)
––1–
–1
LA1-DN10
LA1-DN01
0.020
0.020
2
1 (D09…D95)
––11
LA1-DN11
0.030
2–
LA1-DN20
0.030
–2
LA1-DN02
0.030
2 (D09…D95)
––11
LA8-DN11
0.030
2–
LA8-DN20
0.030
4
1 (D09…D95)
––22
LA1-DN22
0.050
13
LA1-DN13
0.050
4–
LA1-DN40
0.050
–4
LA1-DN04
0.050
31
LA1-DN31
0.050
http://www.DataSheet4U.net/
2 2 (2) LA1-DC22
0.050
With terminal referencing conforming to standard EN 50012
2 1 (D0910…D3210) –
––11
LA1-DN11M
0.030
1 (D0900…D3200) –
––11
LA1-DN11P
0.030
1 (D40…D95)
––11
LA1-DN11G
0.030
4 1 (D0910…D3210) –
––22
LA1-DN22M
0.050
1 (D0900…D3200) –
––22
LA1-DN22P
0.050
1 (D40…D95)
––22
LA1-DN22G
0.050
Instantaneous auxiliary contact blocks with dust and damp protected
contacts (1)
1
For use in harsh industrial environments
2
1 (D09…D95)
2–––
LA1-DX20
– 2 (3)– –
LA1-DY20
4
1 (D09…D95)
2–2–
LA1-DZ40
2–11
LA1-DZ31
(1) Maximum mounting capacity, depending on type of coil.
Device Coil
Operation
Maximum number of add-on blocks
type type
guaranteed
Clip-on mounting
from front
side
LC1-D 50 or 60 Hz
0.8…1.1 Uc
1
+
2
50/60 Hz
0.8…1.1 Uc
1
or 2
0.85…1.1 Uc
1
(2) Including 1 N/O and 1 N/C make before break.
(3) Device fitted with 4 terminals for earth screen continuity.
+
2
0.040
0.040
0.050
0.060
Te
1/33
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LA8-DN
LC1-D09, D12, D18
LA8-DN
LA1-DN10, DN01
LC1-D25, D32
http://www.DataSheet4U.net/
LA6-DK
LA1-DN
LA1-DN, DC
LC1-D40, D50, D65, D80, D95
LA2-DT, DS
LA3-DR
Te1/34
LA1-DX, DY, DZ
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/34
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Auxiliary contact blocks and accessories
Control circuit : a.c.
References
Time delay auxiliary contact blocks (1)
Number
of
contacts
Maximum number of Time delay
blocks per contactor Type
Front clip-on mounting
Setting
range
1 N/O
+
1 N/C
1 (D09…D95)
On-delay
0.1…3 s (2)
0.1…30 s
Reference
LA2-DT0
LA2-DT2
Weight
kg
0.060
1
0.060
10…180 s
LA2-DT4
0.060
1…30 s (3)
LA2-DS2
0.060
Off-delay
0.1…3 s (2)
LA3-DR0
0.060
http://www.DataSheet4U.net/
0.1…30 s
LA3-DR2
10…180 s
LA3-DR4
0.060
0.060
Mechanical latch blocks (1)
Unlatching Clip-on
control
front mounting
Manual
or
electric
LC1-D09…D65
LC1-D80…D95
Basic reference.
To be
completed (4)
LA6-DK10i
Weight
kg
0.070
LA6-DK20i
0.090
(1) Maximum mounting capacity, depending on type of coil.
Device
Coil
Operation Maximum number of add-on blocks
type type
guaranteed Clip-on mounting
from front
side
LC1-D
50 or 60 Hz
0.8…1.1 Uc 1
+
2
50/60 Hz
0.8…1.1 Uc 1 or 2
0.85…1.1 Uc 1
+
2
(2) With extended scale from 0.1 to 0.6 s.
(3) With switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O
contact.
(4) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c or a 12 24 32/36 42/48 60/72 100 110/127 220/240 255/277 380/415
Code
J BC
E
EN K
F
MU
Q
Te
1/35
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LA8-DN
LP1-D09, D12, D18
LA8-DN
LA1-DN10
LA1-DN01
LP1-D25, D32
http://www.DataSheet4U.net/
LA6-DK
LA1-DN
LA1-DN, DC
LA2-DT, DS
LP1-D40, D50, D65, D80
LA3-DR
Te1/36
LA1-DX, DY, DZ
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/36
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Auxiliary contact blocks and accessories
Control circuit : d.c.
References
Instantaneous auxiliary contact blocks (1)
For use in normal operating environments
Number Max. number of blocks per contactor
of Clip-on mounting
contacts Front
Side
Composition
Reference
Weight
kg
1 1 (D25 and D32) –
2 (D40…D80)
––1–
–1
LA1-DN10
LA1-DN01
0.020
0.020
2
1 (D09…D80)
––11
2–
–2
LA1-DN11
LA1-DN20
LA1-DN02
0.030
0.030
0.030
2 (D09…D32)
––11
2–
LA8-DN11
LA8-DN20
0.030
0.030
4
1 (D09…D80)
––22
LA1-DN22
13
LA1-DN13
4–
LA1-DN40
–4
LA1-DN04
31
LA1-DN31
2 2 (2) LA1-DC22
0.050
0.050
0.050
0.050
0.050
0.050
Instantaneous auxiliary contact blocks with dust and damp protected
contacts (1)
1
For use in harsh industrial environments
2
1 (D09…D80)
http://www.DataSheet4U.net/
2–––
2 2 (3)– –
LA1-DX20
LA1-DY20
0.040
0.040
4
1 (D09…D80)
2–2–
2–11
Time delay auxiliary contact blocks (1)
LA1-DZ40
LA1-DZ31
0.050
0.060
Number Max. number of blocks per contactor
of Clip-on mounting
contacts Front
Side
Time delay
Type Setting
range(s)
Reference
Weight
kg
1 N/O
+
1 N/C
1 (D09…D80)
On
delay
0.1…3 (4) LA2-DT0
0.1…30 LA2-DT2
0.060
0.060
10…180 LA2-DT4
0.060
1…30 (5) LA2-DS2
0.060
Off
delay
0.1…3 (4) LA3-DR0
0.1…30 LA3-DR2
0.060
0.060
10…180 LA3-DR4
Mechanical latch blocks (Manual or electric unlatching control)
0.060
Front clip-on
mounting
Basic reference.
To be
completed (6)
Weight
kg
LP1-D09…D65
LA6-DK10i
0.070
LP1-D80
LA6-DK20i
0.090
(1) Either of the following may be fitted, as required: 2 side-mounting contact blocks or 1 front mounting
contact block.
(2) Including 1 N/O + 1 N/C make before break.
(3) Device fitted with 4 terminals for earth screen continuity.
(4) With extended scale from 0.1 to 0.6 s.
(5) With switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O
contact.
(6) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Volts c or a 12 24 32/36 42/48 60/72 100 110/127 220/240 255/277 380/415
Code
J BC
E
EN K
F
MU
Q
Te
1/37
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LA4-DT
LA4-DR
LA4-DF
LA4-DL
LA4-DW
LA4-DM
LC1-D09, D12, D18
LC1-D25, D32
http://www.DataSheet4U.net/
LC1-D40, D50, D65, D80, D95
LA4-DT
LA4-DF
LA4-DL
LA4-DM
LA4-DV
LP1-D09, D12, D18
LP1-D25, D32
Te1/38
LP1-D40, D50, D65, D80
LA4-DV
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/38
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Accessories
References
Electronic serial timer modules (1)
Operational voltage (2)
c LC1-
24…250 V 100…250 V
a LP1-
24…250 V
Time delay Reference
On-delay type
D09…D32 D40…D95
D09…D32
0.1…2 s
LA4-DT0U
1.5…30 s LA4-DT2U
25…500 s LA4-DT4U
Off-delay type
D09…D18 D25…D95
0.1…2 s
LA4-DR0U
1.5…30 s LA4-DR2U
Interface modules (1)
25…500 s LA4-DR4U
Operational voltage
c LC1-
24…250 V 100…250 V 380…415 V
a LP1-
24…250 V
Supply
voltage
E1-E2 (a)
Reference
Relay interface
––
D09…D95
24 V
LA4-DFBQ
D09…D95 –
D09…D32
24 V
LA4-DFB
http://www.DataSheet4U.net/
48 V
LA4-DFE
Relay interface with manual override switch (output forced “ON”)
D09…D95 –
D09…D32
24 V
LA4-DLB
48 V
LA4-DLE
Solid state interface
D09…D32 D40…D95 –
24 V
LA4-DWB
Auto-Man-Stop control modules (1)
Weight
kg
1
0.040
0.040
0.040
0.050
0.050
0.050
Weight
kg
0.055
0.050
0.050
0.045
0.045
0.045
For local override operation tests with 2-position “Auto-Man” switch and “O-I” switch
Operational voltage
Reference
c LC1-
a LP1-
24…100 V 100…250 V
24…100 V 100…250 V
Weight
kg
D09…D95 –
D09…D32 –
LA4-DMK
0.040
– D09…D95
Indicators (contactor state)
D09…D32
LA4-DMU
0.040
Red LED
For mounting on contactors Supply
LC1 and LP1
voltage (c and a)
Clips into
legend plate
location on all
contactor sizes
12…72 V
72…250 V
Sold in
lots of
5
5
Unit
reference
LA4-DVE
LA4-DVM
Weight
kg
0.010
0.010
250…440 V
5 LA4-DVR
(1) Mounted at top on terminals A1 and A2 (screw fixing).
(2) For 24 V operation, the contactor must be fitted with a 21 V coil (code Z). See pages 1/49 to 1/52.
Te
0.010
1/39
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1 LA4-Dq1
LA4-Dq2
LC1-D09, D12, D18
LC1-D25, D32
http://www.DataSheet4U.net/
LC1-D40, D50, D65, D80, D95
LA4-Dq1
LA4-Dq2
LA4-Dq3
LP1-D09, D12, D18
Te1/40
LP1-D25, D32
LP1-D40, D50, D65, D80
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/40
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Accessories
References
Coil suppressor modules
RC circuits (resistor-capacitor) (1)
Mounted at top
For use with contactor (2)
of contactor on
Rating
Type
coil terminals A1 and A2
c LC1- a LP1-
VV
Clip-on fixing and electrical
connection. Fitting of an input
module is still possible.
D09…D32 24…48 –
50…127 –
110…240 –
Screw fixing
D09…D95
24…48 –
50…127 –
110…240 –
380…415 –
Varistors (peak limiting) (3)
Clip-on fixing and electrical
connection. Fitting of an input
module is still possible.
D09…D32 24…48 24…48
50…127 50…127
110…250 110…250
Screw fixing
D09…D32 24…48 24…48
50…127 50…127
110…250 110…250
D40…D95 24…48 –
50…127 –
110…250 –
D40…D80
http://www.DataSheet4U.net/
24…48
50…127
110…250
Diodes (4)
Clip-on fixing and electrical
connection. Fitting of an
input module is still possible.
D09…D32 –
12…250
Reference
LA4-DA1E
LA4-DA1G
LA4-DA1U
LA4-DA2E
LA4-DA2G
LA4-DA2U
LA4-DA2N
LA4-DE1E
LA4-DE1G
LA4-DE1U
LA4-DE2E
LA4-DE2G
LA4-DE2U
LA4-DE2E
LA4-DE2G
LA4-DE2U
LA4-DE3E
LA4-DE3G
LA4-DE3U
LA4-DC1U
1Weight
kg
0.012
0.012
0.012
0.018
0.018
0.018
0.018
0.012
0.012
0.012
0.018
0.018
0.018
0.018
0.018
0.018
0.018
0.018
0.018
0.012
Screw fixing
D09…D32 –
12…250
LA4-DC2U
0.018
D40…D80 –
24…250
LA4-DC3U
0.018
Bidirectional peak limiting diode (5)
Clip-on fixing and electrical
connection. Fitting of an
input module is still possible.
D09…D32 24
72
24
72
LA4-DB1B
LA4-DB1S
0.012
0.012
Screw fixing
D09…D32 24
72
24
72
LA4-DB2B
LA4-DB2S
0.018
0.018
D40…D95 24
72
LA4-DB2B
LA4-DB2S
0.018
0.018
D40…D80 –
24
LA4-DB3B
0.018
– 72
LA4-DB3S
0.018
(1) Effective protection for circuits highly sensitive to “high frequency” interference.
Voltage limited to 3 Uc max and oscillating frequency limited to 400 Hz max.
Slight increase in drop-out time (1.2 to 2 times the normal time).
(2) For satisfactory protection, a suppressor module must be fitted across the coil of each contactor
(3) Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
(4) No overvoltage or oscillating frequency.
Increase in drop-out time (6 to 10 times the normal time).
Polarised component.
(5) Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Te
1/41
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

1
LA9-D1260
LA9-D1261
LA9-D1262
LA9-D1263
LA9-D1860
LA9-D2560
LA9-D3260
LA9-D40961
LA9-D80961
LA9-D40963
LA9-D80962
LA9-D2561
LA9-D2563
http://www.DataSheet4U.net/
LA9-D6567
LC1-D32
LP1-D32
LA9-D80963
LA9-D8067
LC1-D18
LP1-D18
LC1-D09, D12
LP1-D09, D12
LC1-D25
LP1-D25
Te1/42
LC1-D40, D50, D65
LP1-D40, D50, D65
LA9-D941
LC1-D80, D95
LP1-D80
LA9-D92
LA9-D93
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

Illustrations :
page 1/42
Contactors
d 3 and 4-pole contactors, reversing and changeover contactors
Accessories
References
Accessories for main pole and control connections
Description
Connectors
for cable
sizes :
4-pole
10 mm2
3-pole
25 mm2
For use on contactors
c LC1-
a LP1-
D09, D12
D09, D12
Sold in Unit
lots of reference
1 LA9-D1260
D18
D2500, D32
D18
D32
1 LA9-D1860
1 LA9-D3260
Weight
kg
0.030
1
0.035
0.040
4-pole
25 mm2
D25
D25 1 LA9-D2560
0.050
Links for
parallel
connection of
2 poles
D09, D12
D25
D09, D12
D25
10
10
LA9-D1261
LA9-D2561
0.012
0.060
D40…D65
D40…D65 2
LA9-D40961
0.021
D80, D95
D80
2 LA9-D80961
0.060
3 poles
D09, D12
(star
connection) D80, D95
D09, D12
D80
10
1
LA9-D1262
LA9-D80962
0.003
0.080
4-pole
D09, D12
D09, D12 2
LA9-D1263
0.024
D25 D25 2 LA9-D2563
0.017
D40…D65
D40…D65 2
LA9-D40963
0.070
http://www.DataSheet4U.net/
D80, D95
Staggered coil connection
D80
D40…D80
2
10
LA9-D80963
LA9-D09966
0.100
0.006
Control circuit take-off
from main pole
D40…D65
D80
Accessories for protection and marking
10
10
LA9-D6567
LA9-D8067
0.010
0.010
Description
For use on
Contactors
c LC1- a LP1-
Add-on
blocks
Sold in Unit
lots of reference
Weight
kg
Miniature fuse holder D09…D95 D09…D80 –
type 5 x 20 with
4 A - 250 V fuse
1 LA9-D941
0.025
Legend holder
8 x 22 mm snap-in
D09…D95 D09…D80 LA1-D
100
(4 contacts)
LA2-D, LA3-D
LA6-DK
LA9-D92
0.001
Legend holder
LA1-DN
100 LA9-D90
8 x 17 mm snap-in
(2 contacts)
0.001
Bag of 300 labels
(blank, self-adhesive)
7 x 21 mm
D09…D95 D09…D80 LA1-D
1
(4 contacts)
LA2-D, LA3-D
LA6-DK
LA9-D93
0.001
Bag of 400 labels
(blank, self-adhesive) 7 x 16 mm
LA1-DN
1
(2 contacts)
LA9-D91
0.001
Sealing cover
Accessories for mounting
LA2, LA3-D 1
LA9-D901
0.005
Adaptor for mounting
on ' rail
D09…D32 D09…D32 –
Mounting plates
for fixing on 2 ' rails D09…D18 D09…D18 –
(120 mm fixing centres) D25…D32 D25…D32 –
Set of shims
for fitting side-mounting blocks LA8-DN on LC1-D40 to D95
1
10
10
1
LA9-D973
DX1-AP25
DX1-AP26
LA9-D511
Te
0.025
0.065
0.082
0.020
1/43
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
pages 1/18 and 1/20
LC1-D09, D12
1 Minimum electrical
clearance
Contactors
d 3 and 4-pole contactors, type LC1-D
Dimensions
LC1-D18
LC1-D2500
44
Minimum electrical
LA4 clearance
44
LA4
10 93
113(2)(LA1)
136(LA6-DK1)
145(1) (LA2,LA3,LA6-DK2)
12,5 45 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts
(3) With or without combined use of a coil suppressor module
LA4-DA1, DE1
LC1-D2510, D2501, D25004
= 44 =
Minimum electrical
clearance
LA4
145(1)
10 93
126(2)(LA1)
136(LA6-DK1)
(LA2,LA3,LA6-DK2)
12,5 56 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact = 120 (LA1-DN10 or DN01)
(3) With or without combined use of a coil suppressor module
LA4-DA1, DE1
LC1-D40, D50, D65
28 44
Minimum electrical
clearance
LA4
137(1)
10 85
118(2)(LA1)
128(LA6-DK1)
(LA2,LA3,LA6-DK2)
12,5 45 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts
(3) With or without combined use of a coil suppressor module
LA4-DA1, DE1
LC1-D32
= 44 =
Minimum electrical
clearance
LA4
http://www.DataSheet4U.net/
150(1)
10 98
131(2)(LA1)
141(LA6-DK1)
(LA2,LA3,LA6-DK2)
12,5 56 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact = 125 (LA1-DN10 or DN01)
(3) With or without combined use of a coil suppressor module
LA4-DA1, DE1
LC1-D80, D95
32 44
Minimum electrical
clearance
LA4
12 114(4)
145(2)(LA1)
12,5 (3) 12,5
(LA8)
(LA8)
164(1)(LA2,LA3,LA6-DK2)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact = 139 (LA1-DN10 or DN01)
(3) 75 : 3 poles, 85 : 4 poles
(4) 125 : LC1-Dii008
Te1/44
12 125(4)
153(2)(LA1)
172(1)(LA2,LA3,LA6-DK2)
12,5
(LA8)
(3)
12,5
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact = 147 (LA1-DN10 or DN01)
(3) 85 : 3 poles, 96 : 4 poles
(4) 140 : LC1-Dii008
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
page 1/19 and 1/21
LP1-D09, D12
Minimum electrical
clearance
Contactors
d 3 and 4-pole contactors, type LP1-D
Dimensions
LP1-D18
44
Minimum electrical
LA4 clearance
44
LA4
1
10 115
148(2)(LA1)
158(LA6-DK1)
167(1)(LA2,LA3,LA6-DK2)
12,5 45 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts
(3) With or without combined use of a coil suppressor module
LA4-DC1, DE1.
LP1-D25
Minimum electrical
clearance
= 44 =
LA4
10 120
153(2)(LA1)
163(LA6-DK1)
172(1)(LA2,LA3,LA6-DK2)
12,5 45 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts
(3) With or without combined use of a coil suppressor module
LA4-DC1, DE1.
LP1-D32
Minimum electrical
clearance
= 44 =
LA4
http://www.DataSheet4U.net/
10 130
163(2)(LA1)
173(LA6-DK1)
182(1)(LA2,LA3,LA6-DK2)
12,5 56 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact : 157 (LA1-DN10 or DN01)
(3) With or without combined use of a coil suppressor module
LA4-DC1, DE1.
LP1-D40, D50, D65
Minimum electrical
clearance
LA4-Di3
10 135
168(2)(LA1)
178(LA6-DK1)
187(1)(LA2,LA3,LA6-DK2)
12,5 56 12,5
(LA8)
(LA8)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact : 162 (LA1-DN10 or DN01)
(3) With or without combined use of a coil suppressor module
LA4-DC1, DE1.
LP1-D80
Minimum electrical
clearance
LA4-Di3
12 171(4)
202(2)(LA1)
221(1)(LA2,LA3,LA6-DK2)
(3)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact : 196 (LA1-DN10 or DN01)
(3) 75 : 3 poles, 85 : 4 poles
(4) 182 : LP1-Dii008
12 181(4)
210(2)(LA1)
229(1)(LA2,LA3,LA6-DK2)
(3)
(1) + 4 mm with lead sealing kit
(2) With 2 or 4 contacts; 1 contact : 204 (LA1-DN10 or DN01)
(3) 85 : 3 poles, 96 : 4 poles
(4) 196 : LP1-Dii008
Te
1/45
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
pages 1/22 and 1/23
LC2-D09 to D32
2 x LC1-D09 to D32
1
Contactors
d 3-pole reversing and 4-pole changeover contactors
Types LC2-D and LP2-D
Dimensions (1)
2xØ4,5
LP2-D09 to D32
2 x LP1-D09 to D32
2xØ4,5
c =G=
a
LC2- or 2 x LC1-
a
D09, D12
105
D18 106
D25 127
D32 127
c, e1 and e2 including cabling
LC2-D40 to D65
2 x LC1-D40 to D65
b
74
74
84
84
c e1 (3 P) e2 (4 P) G
84 7 6 95
92 8 – 95
99 8 7 111
117 10
111
6xØ6,5
= G1 =
c
LP2- or 2 x LP1-
a
D09, D12
105
D18 106
D25 127
D32 127
c, e1 and e2 including cabling
b
74
74
84
84
=G=
a
c e1 (3 P) e2 (4 P) G
119 7
6
95
127 8
95
136 8
7
111
154 10
111
2 x LP1-D40 to D65
6xØ6,5
= G1 =
http://www.DataSheet4U.net/
c = 40 G 40 =
a
LC2- or 2 x LC1- (3 P) a
bc
e1 G
G1
D40, D50, D65
165 127 142 5
50 90
LC2- or 2 x LC1- (4 P) a
bc
e2 G
G1
D40, D65
182 127 133 11 57 97
c, e1 and e2 including cabling
LC2-D80 and D95
2 x LC1-D80 and D95
6xØ6,5
= G1
=
c = 40 G 40 =
a
2 x LP1- (3 P)
D40, D50, D65
a b c e1
165 127 199 5
2 x LP1- (4 P)
a b c e2
D40, D65
182 127 190 11
c, e1 and e2 including cabling
G
50
G
57
G1
90
G1
97
2 x LP1-D80
6xØ6,5
= G1
=
c
= 40 G 40 =
c = 40 G 40 =
aa
LC2- or 2 x LC1- (3 P) a
bc
e1 G
G1
D80, D95
182 127 158 13 57 96
2 x LP1- (3 P)
D80
a b c e1
182 127 215 13
LC2- or 2 x LC1- (4 P) a
bc
e2 G
G1
D80 207 127 158 20 71 111
c, e1 and e2 including cabling
2 x LP1- (4 P)
a b c e2
D80 207 127 215 20
c, e1 and e2 including cabling
(1) Dimensions with auxiliary contact blocks and add-on modules see pages 1/44 and 1/45.
Te1/46
G
57
G
71
G1
96
G1
111
datasheet pdf - http://www.DataSheet4U.net/


LC1-D3210xx (Telemecanique)
Contactors

No Preview Available !

Click to Download PDF File for PC

References :
pages 1/18 to 1/21
LC1-D09 to D32
Panel mounted
Contactors
d 3 and 4-pole contactors, types LC1-D and LP1-D
Mounting
2xØ4,8
2xØ4,5
LC1-D40 to D95
Panel mounted
3xØ6,5
c = G=
c = 40 =
LC1- D09 D12 D18 D25 D32
c 80 80 85 93 98
G 35 35 35 44 44
LP1-D09 to D32
Panel mounted
2xM4
2xØ4,5
LP1-D25 and D32
LC1- D40 D50 D65 D80 D95
c 114 114 114 125 125
LP1-D40 to D80
Panel mounted
http://www.DataSheet4U.net/
c
= G=
=G =
c
3xØ6,5
= 40 =
LP1- D09 D12 D18 D25 D32
c 115 115 120 130 135
G 35 35 35 50 50
LC1-D09 to D32
On mounting rail AM1-DP200 or AM1-DE200
LP1- D40 D50 D65 D80
c 171 171 171 181
LC1-D40 to D95
On mounting rail AM1-DL200 or DL201 (width 75 mm)
On mounting rail AM1-EDiii or AM1-DE200 (width 35 mm)
1
c
LC1-
b
c (AM1-DP200)
c (AM1-DE200)
D09 D12 D18 D25 D32
74 74 74 84 84
82 82 87 95 100
90 90 95 103 108
c
LC1-
D40 D50 D65 D80 D95
c (AM1-DL200)
131 131 131 142 142
c (AM1-DL201/
121 121 121 132 132
c (AM1-EDiii or DE200) 121 121 121 132 132
Te
1/47
datasheet pdf - http://www.DataSheet4U.net/




LC1-D3210xx.pdf