SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET
SKY65336-11: 2.4 GHz Transmit/Receive Front-End Module
with Integrated LNA
Applications
x 2.4 GHz ISM band radios
x ZigBee® FEMs
x IEEE 802.15.4 applications
Features
x Transmit output power > +20 dBm
x Receive NF < 3 dB
x High efficiency PA
x Programmable transmit power levels
x Configurable transmit/receive paths
x Internal switching and control circuits
x Internal RF match and bias circuits
x Single DC supply = 3.0 V
x Interfaces seamlessly with Ember EM250 and EM260 ZigBee
transceivers
x All RF ports are internally DC blocked
x Small footprint, MCM (28-pin, 8 x 8 mm) SMT package (MSL3,
260 qC per JEDEC J-STD-020)
Description
Skyworks SKY65336-11 is a high-efficiency Front-End Module
(FEM) for ZigBee and other 2.4 GHz ISM band applications. The
small
8 x 8 mm Multi-Chip Module (MCM) contains a 2400-2500 MHz
high-efficiency transmit path and a low-noise linear receive path.
The transmit path consists of an harmonic filter and high
efficiency Power Amplifier (PA) capable of providing +20 dBm of
power at the antenna port. Also included is an internal balun to
allow use of differential input signals.
The receive path contains a high isolation Transmit/Receive
(Tx/Rx) switch, Low Noise Amplifier (LNA), and balun for low noise
differential output.
The device is mounted in a 28-pin, 8 x 8 mm MCM Surface-
Mounted Technology (SMT) package, which allows for a highly
manufacturable low-cost solution.
A block diagram of the SKY65336-11 is shown in Figure 1. The
device package and pinout for the 28-pin MCM are shown in
Figure 2.
Skyworks offers lead (Pb)-free RoHS (Restriction of
Hazardous Substances) compliant packaging.
Tx Input
Differential
RF Port
1.8 V Bias
Rx Output
Differential
RF Port
1.8 V Bias
PA
LNA
Harmonic
Filter
2
1
T/R Switch
50 Ω Single-Ended
Port to Antenna
Figure 1. SKY65336-11 Block Diagram
S1293
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
1
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
BIAS1_PASS 1 28 27 26 25 24 23 22 GND
TX_N 2
21 GND
TX_P 3
20 GND
GND 4
GND 5
Ground
Bottom Paddles
19 GND
18 ANT
BIAS2_PASS 6
17 GND
RX_N 7
16 GND
RX_P 8 9 10 11 12 13 14 15 GND
S1287
Figure 2. SKY65336-11 Pinout – 28-Pin MCM
(Top View)
Technical Description
Transmit/Receive (Tx/Rx) Enable
Pin 27 (TX_EN) and pin 12 (RX_EN) are used to enable the
transmit and receive port, respectively.
Tx/Rx Switch
Pin 28 (T_R) is used to control the Tx/Rx switch.
Tx/Rx Enable and Tx/Rx Switch Mode Control
The following control logic is used to configure the transmit or
receive mode of the SKY65336-11:
TX_EN
High
Low
RX_EN
Low
High
T_R Mode
High Transmit mode
Low Receive mode
High Power and Low Power Modes
High power mode output is 20 dBm and low power mode output
is 10 dBm. Pin 26 (TX_HLB) sets the transmit path in high power
or low power mode according to the following logic:
TX_HLB
Low
High
State
High power mode
Low power mode
Bottom Center Paddles
The bottom center paddles must be electrically grounded for
proper RF performance. Customers should place adequate
thermal vias under the ground paddles for optimum thermal
performance. The Evaluation Board layout (see Figures 3 and 4)
can be used as a guide for RF ground and thermal layout.
Electrical and Mechanical Specifications
Signal pin assignments and functional pin descriptions are
described in Table 1. The absolute maximum ratings of the
SKY65336-11 are provided in Table 2. Recommended operating
conditions are noted in Table 3 and electrical specifications are
provided in Table 4.
Typical performance characteristics of the SKY65336-11 are
shown in Figures 3 through 12.
Package and Handling Information
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
The SKY65336-11 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 qC. It can be used for lead or lead-free soldering. For
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format. For packaging details, refer to the Skyworks
Application Note, Tape and Reel, document number 101568.
Table 1. SKY65336-11 Signal Descriptions
Pin # Name
Description
1 BIAS1_PASS
Transmit port bias supply
2 TX_N
Negative transmit input port
3 TX_P
Positive transmit input port
4 GND
Ground
5 GND
Ground
6 BIAS2_PASS
Receive port bias supply
7 RX_N
Negative receive output port
8 RX_P
Positive receive output port
9 GND
Ground
10 GND
Ground
11 RX_VCC
Receive DC supply, +3 V
12 RX_EN
Receive enable
13 GND
Ground
14 GND
Ground
Note: The bottom ground pad must be connected to RF ground.
Pin #
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Name
GND
GND
GND
ANT
GND
GND
GND
GND
GND
TX_VCC
GND
TX_HLB
TX_EN
T_R
Description
Ground
Ground
Ground
Antenna input
Ground
Ground
Ground
Ground
Ground
Transmit DC supply, +3 V
Ground
Transmit power mode
Transmit enable
Transmit/receive switch
Table 2. SKY65336-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
RX_VCC, TX_VCC
2.1
4
V
Control Voltage
BIAS1_PASS,
BIAS2_PASS, TX_EN,
RX_EN, TX_HLB, T_R
3.6 V
Bypass voltage
BIAS1_PASS, BIAS2_PASS
1.9 V
RF input power, antenna port
PIN_ANT
10 dBm
RF input power, transmit port
PIN_TX
+8 dBm
Case operating temperature
TC
–40 +85
qC
Storage temperature
TST
–55 +125
qC
Junction temperature
TJ
+150
qC
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
3
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Table 3. SKY65336-11 Recommended Operating Conditions
Parameter
Symbol
Supply voltage (TX_VCC, RX_VCC)
VCC
Tx/Rx bias supply voltage
BIAS1_PASS,
BIAS2_PASS
Tx/Rx enable voltage:
Low
High
TX_ENL, RX_ENL
TX_ENH, RX_ENH
Tx/Rx control voltage:
Low
High
T_RL, TX_HLBL
T_RH, TX_HLBH
Frequency range
f
Minimum
2.7
1.7
1.62
1.62
2400
Typical
3.0
1.8
0
1.80
0
1.80
Maximum
3.6
1.9
0.1
VCC – 0.2
0.1
VCC – 0.2
2500
Units
V
V
V
V
V
V
MHz
Table 4. SKY65336-11 Electrical Specifications (Note 1)
(VCC = 3.0 V, TC = 25 °C, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min Typical Max
Units
Frequency range
f
2400 2500 MHz
Return loss
RL All RF ports
6 10
dB
Transmitter Section
Input power range
Transmit saturated output power
Operating current
PIN CW, high or low power
mode
+3 +5 dBm
PSAT_H
High power mode
+19.5
+20
dBm
PSAT_L
Low power mode
+8 +10
dBm
IOP_H POUT = +20 dBm in high
power mode
145 160 mA
IOP_L POUT = +10 dBm in low
power mode
70 80 mA
Harmonic levels
Saturated gain
Leakage current
PN CW, POUT = +20 dBm in
high power mode,
POUT = +10 dBm in low
power mode
GH CW, high power mode
GL CW, low power mode
ILEAK No RF input, VCC = 3.0 V,
RX_EN = 0 V,
TX_EN = 0 V
–44 –40 dBm
17 dB
7 dB
0.5 2.0 μA
Receiver Section (Frequency = 2445 MHz)
Small signal gain
Noise Figure
G CW
NF
9.5 10.5
2.0 3.0
dB
dB
Input 1 dB compression
IP1dB
CW
–11 dBm
Input IP3
IIP3 Two CW tones spaced –1
1 MHz apart
@ PIN = –9 dBm
+3
dBm
Operating current
ICC CW
8 15 mA
Leakage current
ILEAK No RF input, VCC = 3.0 V,
RX_EN = 0 V,
TX_EN = 0 V
0.5 2.0 μA
Note 1: Performance is guaranteed only under the conditions listed in this Table and is not guaranteed over the full operating or storage temperature ranges. Operation at elevated
temperatures may reduce reliability of the device.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
Typical Performance Characteristics
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
+23
+21
+19
+17
+15
+13
+11 2.7 V
3.0 V
+9 3.3 V
+7 3.6 V
+5
–10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 +1 +2 +3 +4 +5 +6
Input Power (dBm)
Figure 3. Output Power vs Input Power Over Voltage @ 2450 MHz
(TA = 25 °C)
+23
+21
+19
+17
+15
+13
–40 oC
+25 oC
+11 +85 oC
+9
+7
+5
–10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0 +1 +2 +3 +4 +5 +6
Input Power (dBm)
Figure 4. Output Power vs Input Power Over Temperature
@ 2450 MHz (VCC = 3 V)
+22.5
+22.0
+21.5
+21.0
+20.5
+20.0
+19.5
+19.0
2400
2450
Frequency (MHz)
2.7 V
3.0 V
3.3 V
3.6 V
2500
Figure 5. Saturated Output Power vs Frquency Over Voltage
(TA = 25 °C)
0.18
0.16
0.14
0.12
0.10
0.08
0.06
0.04
+4
2.7 V
3.0 V
3.3 V
3.6 V
+6 +8 +10 +12 +14 +16 +18 +20 +22 +24
Output Power (dBm)
Figure 7. Operating Current vs Output Power Over Voltage
@ 2450 MHz (TA = 25 °C)
+22.0
+21.8
+21.6
+21.4
+21.2
+21.0
+20.8
+20.6
+20.4
+20.2
+20.0
2400
2450
Frequency (MHz)
–20 oC
+25 oC
+85 oC
2500
Figure 6. Saturated Output Power vs Frequency Over Temperature
(VCC = 3 V)
0.19
0.17
0.15
0.13
0.11
0.09 –40 oC
+25 oC
0.07 +85 oC
0.05
+4 +6 +8 +10 +12 +14 +16 +18 +20 +22 +24
Output Power (dBm)
Figure 8. Operating Current vs Output Power Over Temperature
@ 2450 MHz (Voltage = 3 V)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
5
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
–48.0
–48.5
–49.0
–49.5
–50.0
–50.5
–51.0
–51.5
–52.0
–52.5
2400
2450
Frequency (MHz)
2.7 V
3.0 V
3.3 V
3.6 V
2500
Figure 9. Second Harmonics vs Frequency Over Voltage
(High Power Mode)
–48
–49
–50
–51
–52
–53
–54
–55
–56
–57
–58
2400
2450
Frequency (MHz)
2.7 V
3.0 V
3.3 V
3.6 V
2500
Figure 10. Third Harmonics vs Frequency Over Voltage
(High Power Mode)
–43
–44
–45
–46
–47
–48
–49
–50
–51
–52
2400
2450
Frequency (MHz)
2.7 V
3.0 V
3.3 V
3.6 V
2500
Figure 11. Fourth Harmonics vs Frequency Over Voltage
(High Power Mode)
Evaluation Board Description
The SKY65336-11 Evaluation Board is used to test the
performance of the SKY65336-11 FEM. The Evaluation Board
schematic diagram is shown in Figure 13. An assembly drawing
for the Evaluation Board is shown in Figure 14.
–55
–57
–59
–61
–63
–65
–69
–71
–73
–75
2400
2450
Frequency (MHz)
2.7 V
3.0 V
3.3 V
3.6 V
2500
Figure 12. Fifth Harmonics vs Frequency Over Voltage
(High Power Mode)
Package Dimensions
The phone board layout footprint for the SKY65336-11 is shown
in Figure 15. Package dimensions for the 28-pin MCM are shown
in Figure 16, and tape and reel dimensions are provided in
Figure 17.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
6 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
DC SUPPLY 1
6543 21
BP1 T_R
BP1 T_R
TX_HLB GND
TX_EN
TX_VCC
C10
0.1 μF
TX_EN TX_HLB
R1
0Ω
TX_VCC
C3
0.1 μF
C4
1000 pF
J1
Transmit
Input
J2
Receive
Output
R3
1.5 nH
C12
0.2 pF
×
65 4
LDB182G4520C-110
12 3
C11
DNI
C15
DNI
R4
1.5 nH
C14
0.2 pF
×
65 4
LDB182G4520C-110
12 3
C13
DNI
C16
DNI
28 27 26 25 24 23
1
BIAS1_PASS
2 TX_N
3 TX_P
4 GND
5 GND
6 BIAS2_PASS
7 RX_N
8 RX_P
SKY65336-11
22
GND
GND 21
GND 20
GND 19
ANT 18
GND 17
GND 16
GND 15
9 10 11 12 13 14
GND RX_EN
BP2 GND RX_VCC
C9
0.1 μF
1234 5
DC SUPPLY 2
BP2
Note: Some component labels may be different than the corresponding component symbol shown here.
Component values, however, are accurate as of the date of this Data Sheet.
C8
1000 pF
C7
0.1 μF
R2
0Ω
RX_VCC RX_EN
Figure 13. SKY65336-11 Evaluation Board Schematic
J3
Antenna
S1292
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
7
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
J3
C3
C4
C5
C6
R2
J4 C1 R1 C2
C8 C7
C9
C16
C10 C15
T2
C11
R3
C12
C13
R4
C14
J1 J2
J5
Figure 14. SKY65336-11 Evaluation Board Assembly Drawing
S1291
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
8 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Pin 28
Pin 1
0.2 x 0.2
0.9875 Typ
0.875 Typ
Stencil Aperture Size of 80 to 100%
of the Module/Pkg Solder
Mask Openings
Thermal Via Array 0.3 mm
on 0.6 mm Pitch Will Improve
Thermal Performance
Pin 28
Pin 1
6.9124
13X 0.588
6.9124
0.49375
28X 0.588
R0.15 Typ
28X 0.588
0.49375
6.9124
0.875 Typ
Stencil Aperture
Top View
Package Outline
Exposed Center Pad
Pin 28
Pin 1
6.9124
0.49375
28X 0.738
R0.225 Typ
6.9124
1.9082
0.9875 Typ
R0.15 Typ
13X 0.588
0.9875 Typ
2X 2.4375
28X 0.738
0.49375
6.912
Package Outline
0.49375
0.25 Typ
Metallization
Top View
Note: The cross-hatched area represents the merger of the center
ground pad +25 individual I/O ground pads. All I/O ground
pads should have at least one via connected to internal ground
planes for optimum electrical performance.
Solder Mask Opening
Top View
All measurements are in millimeters
Figure 15. SKY65336-11 Phone Board Layout Footprint
Package Outli
Exposed Center Pad
S1330
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
9
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Pin 1
Indicator
8
0.05 A B C
Top View
B
C
8
16X 3.75
4X 2.46875
10X 1
4X 0.49375
4X 1.48125
10X 2
1.3 ± 0.1
// 0.025 A
A
Solder Mask Opening
See Detail D
0.15 A B C
0.08
Side View
Pin 28
Pin 1 Indicator
(See Detail B)
Pin 1
D
D
0
SMT Pad
(See Detail A)
0
Bottom View
SMT Pad
(See Detail C)
28X SMT Pad
0.05 M A B C
0.06 D
(Metal Backside)
(0.588)
Section D-D
Scale: 6X
D
0.888 ± 0.03
2X R0.20
(0.25)
0.688 ± 0.03
0.588 ± 0.025
0.588 ± 0.025
Metal Pad Edge
4X R0.15
Detail A
Pad Scale: 2X
6X This rotation
6X Rotated 180o
6X Rotated 90o CW
6X Rotated 90o CCW
0.875
Solder Mask
Edges
0.875
Detail B
Scale: 2X
Pin 1 Indicator
0.2 x 0.2
4X R0.15
0.888 ± 0.03
Metal Pad Edge
0.588 ± 0.025
R0.20
0.588 ± 0.025
0.888 ± 0.03
(0.25) (0.25)
Detail C
SMT Pad Scale: 2X
1X This rotation
1X Rotated 180o
1X Rotated 90o CW
1X Rotated 90o CCW
0.875
0.875
19 X Detail D
Scale: 2X
Soldermask
Edges
All measurements are in millimeters
Dimensioning and tolerancing according to ASME Y14.5M-1994
S1289
Figure 16. SKY65336-11 28-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
10 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
0.30 ± 0.05
5o
8.35
Pin #1
indicator
12.00
2.00 ± 0.05
B
4.00
AA
1.55 ± 0.05 1.75 ± 0.10
B
1.70
B
Notes:
1. Carrier tape: black conductive polystyrene
2. Cover tape material: transparent conductive PSA
3. Cover tape size: 13.3 mm width
4. All dimensions are in millimeters
5. Pin 1 orientation is in top left corner for the following Skyworks products:
SKY74963-xx
CX74063-35
SKY77503-xx
SKY77506-xx
SKY77512-xx
SKY77526-xx
SKY77343-xx
For all other 8 x 8 mm MCM/RFLGA products, pin 1 orientation is
in top right corner.
8.35
A
5o
Figure 17. SKY65336-11 28-Pin MCM Tape and Reel Dimensions
1.50 Min.
S1290
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
11
Datasheet pdf - http://www.DataSheet4U.net/


SKY65336-11 (Skyworks Solutions)
Transmit/Receive Front-End Module

No Preview Available !

Click to Download PDF File for PC

www.DataSheet.co.kr
DATA SHEET • SKY65336-11 TRANSMIT/RECEIVE FRONT-END MODULE WITH LNA
Ordering Information
Model Name
SKY65336-11 Tx/Rx Front-End Module w/LNA
Manufacturing Part Number
SKY65336-11 (Pb-free package)
Evaluation Kit Part Number
TW17-D475-001
Copyright © 2008, 2009 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
12 November 11, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200939G
Datasheet pdf - http://www.DataSheet4U.net/




SKY65336-11.pdf
Click to Download PDF File