RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

Features
Unregulated
Converters
• 12.5kVAC/1 minute isolation
• Compact SIP16 case with >30mm pin separation
bLuolwlet4poFinmtsax(P. irsoodluactitomnacnaapgaecri)tance
• Wide operating temperature range from
-40°C to +80°C at full load
• Efficiency up to 81%
DC/DC Converter
RHV3
Description
The RHV3 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a
compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, ±5V or ±12V.
The operating temperature is -40°C to +80°C without derating. Applications include high vacuum
monitoring, X-Ray equipment, HVAC dust extraction systems and other high voltage industrial
applications where a very high isolation remote power supply is required.
3 Watt
SIP16
Single and Dual
Output
Selection Guide
Part
Number
nom. Input
Output
Output Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%] [µF]
RHV3-0505S/R20 5 5 600 76 1000
RHV3-0512S/R20 5 12 250 78 330
RHV3-0524S/R20 5 24 125 80 100
RHV3-1205S/R20 12 5 600 78 1000
RHV3-1212S/R20 12 12 250 79 330
RHV3-1224S/R20 12 24 125 80 100
RHV3-2405S/R20 24 5 600 80 1000
RHV3-2412S/R20 24 12 250 80 330
RHV3-2424S/R20 24 24 125 81 100
RHV3-0505D/R20
5 ±5 ±300 78 ±680
RHV3-0512D/R20
5 ±12 ±125 80 ±150
RHV3-1205D/R20 12 ±5 ±300 78 ±680
RHV3-1212D/R20
12 ±12 ±125 81 ±150
RHV3-2405D/R20 24 ±5 ±300 80 ±680
RHV3-2412D/R20
24 ±12 ±125 80 ±150
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: The capacitive load is tested at minimum input and constant resistive load
IEC/EN62368-1 certified
IEC/EN61010-1 certified
Model Numbering
RHV3-__ __
Output Power
nom. Input Voltage
Output Voltage
/R20
Isolation Voltage
Single or Dual Output
www.recom-power.com
REV.: 0/2019
ECO-1


RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
Input Voltage Range
Minimum Load
Internal Operating Frequency
Output Ripple and Noise (3)
Condition
20MHz BW
Min.
0%
20kHz
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output (low ESR)
RHV3
Series
Typ.
±10%
Max.
capacitors
45kHz
150mVp-p
200mVp-p
Efficiency vs. Load
RHV3-0505S/R20
100
90
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RHV3-2424S/R20
100
90
80
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80
Output Load [%]
90 100
RHV3-0505D/R20
100
90
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RHV3-1205S/R20
100
90
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
www.recom-power.com
REV.: 0/2019
ECO-2


RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation (4)
Cross Regulation
Tolerance Envelope
Condition
low line to high line, full load
10% to 100% load
5Vin
others
10% to 100% load
Notes:
Note4: Operation below 10% load will not harm the converter, but specifications may not be met
Value
±5.0% max.
±1.2% of 1.0% Vin typ.
15.0% max.
10.0% max.
±7.5% typ.
RHV3-0505S/R20
RHV3-0524S/R20
+15%
+12.5%
Vnom
Typical Load Line
+5%
+0.5%
-5%
+10%
+8%
Vnom
Typical Load Line
+5%
-1.5%
-5%
10
+15%
+12%
Vnom
50
Output Load [%]
RHV3-0505D/R20
100
Typical Load Line
+5%
+1.5%
-5%
10 50 100
Output Load [%]
RHV3-2412D/R20
+10%
+6.6%
Vnom
Typical Load Line
+5%
-1.5%
-5%
10
+15%
+10%
Vnom
50
Output Load [%]
RHV3-1205S/R20
100
Typical Load Line
+5%
+1%
-5%
10 50 100
Output Load [%]
RHV3-2424S/R20
+10%
+6.5%
Vnom
Typical Load Line
+5%
0%
-5%
10
www.recom-power.com
50
Output Load [%]
100
REV.: 0/2019
10 50 100
Output Load [%]
ECO-3


RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Isolation Voltage (5)
I/P to O/P
Type
tested for 1 second
tested for 1 minute
Value
20kVDC
12.5kVAC
Isolation Resistance
Isolation Capacitance
15GW min.
3.5pF typ./ 4pF max.
Insulation Grade
reinforced
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Altitude
Operating Humidity
Pollution Degree
Vibration
MTBF
Derating Graph
(@ Chamber and natural convection 0.1m/s)
Condition
without derating @ natural convection 0.1m/s (see graph)
non-condensing
according to MIL-HDBK-217F,G.B.
+25°C
+80°C
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
95
www.recom-power.com
REV.: 0/2019
Value
-40°C to +80°C
+105°C
0.02%/K max.
12K/W typ.
5000m
5% - 95% RH max.
PD2
MIL-STD-202G
13400 x 103 hours
3600 x 103 hours
ECO-4


RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

RHV3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements
RoHS 2
Report / File Number
WD-SE-R-190305-A0
WD-SE-R-190305-B0
Standard
IEC62368-1:2014 2nd Edition
EN62368-1:2014+AC:2015
IEC61010:2010
EN61010:2010
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Electromagnetic compatibility of multimedia equipment –
Emission Requirements
Information technology equipment - Immunity characteristics - Limits
and methods of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
EMC Filtering Suggestions according to EN55032
Condition
refer to “EMC Filtering Suggestions”
Air: ±2, 4, 8kV, Contact: ±2, 4kV
3V/m
DC Power Port: ±0.5kV, ±1kV
DC Power (Output) Port: ±0.5kV
DC Power (Output) Port: 3V
50Hz, 1A/m
Standard / Criterion
EN55032, Class B
EN55024:2010 + A1:2015
IEC61000-4-2:2009, Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014+A1:2017, Criteria A
IEC61000-4-6:2013+C1:2015, Criteria A
IEC61000-4-8:2010, Criteria A
Single Output
+Vin
L1
+Vin
+Vout
C1
-Vin
-Vin
-Vout
+Vout
-Vout
Dual Output
+Vin
L1
+Vin
+Vout
C1
-Vin
-Vin
Com
-Vout
+Vout
Com
-Vout
Component List Class B
nom. Input Voltage
5VDC, 12VDC, 24VDC
C1
10µF, 50VDC MLCC
L1
18µH choke RLS-226
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Weight
www.recom-power.com
Type
case
PCB
potting
continued on next page
REV.: 0/2019
Value
black plastic, (UL94V-0)
FR4, (UL94V-0)
epoxy, (UL94V-0)
45.0 x 15.0 x 17.0mm
19.7g typ.
ECO-5


RHV3-0505D-R20 (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing (mm)
RHV3
Series
embossed logo
45.0
0.5±0.10
12
3.45
Bottom View
141516
12 x 2.54 = 30.48
15.0
Marking
Pinning Information
Pin # Single Dual
1 +Vin +Vin
2 -Vin
-Vin
14 -Vout -Vout
15 no pin Com
16 +Vout +Vout
Tolerance:  xx.x= ±0.5mm
 xx.xx= ±0.25mm
0.25±0.10
Recommended Footprint Details
1 2 141516
Top View
2.54
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
Type
tube
non-condensing
Value
520.0 x 26.9 x 17.9mm
10pcs
-55°C to +125°C
5% - 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2019
ECO-6




RHV3-0505D-R20.pdf
Click to Download PDF File