Features
Regulated
Converters
• 2:1 Wide Input Voltage Range
• 1.6kVDC Isolation
• UL Certified
• Efficiency up to 87%
• Fixed Operating Frequency
• Six-Sided Continuous Shield
DC/DC Converter
RP10-E
Description
The RP10-E series DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes them
ideal for all telecom and industrial applications where approved safety standards are required. The
industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance
and is available with an optional remote on/off control pin. This series is also available with the /M1 and
/M2 option which is particularly suitable for extended temperature range applications.
10 Watt
2“ x 1“
33 YEAR
warranty
Single & Dual
Output
Selection Guide
Part Number
Input
Output Output Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current typ.
Load(2)
[VDC] [VDC] [mA] [mA] [%] [µF]
RP10-123.3SE(3,4) 9-18 3.3 2000 688 80 6800
RP10-1205SE(3,4)
9-18
5
2000 1029
81
4700
RP10-1212SE(3,4) 9-18 12 830 988 84 690
RP10-1215SE(3,4) 9-18 15 670 997 84 470
RP10-243.3SE(3,4)
18-36
3.3 2000
344
80
6800
RP10-2405SE(3,4) 18-36 5 2000 508 82 4700
RP10-2412SE(3,4)
18-36
12 830 494 84
690
RP10-2415SE(3,4) 18-36 15 670 499 84 470
RP10-483.3SE(3,4) 36-75 3.3 2000 172 80 6800
RP10-4805SE(3,4)
36-75
5
2000
248
84
4700
RP10-4812SE(3,4) 36-75 12 830 241 86 690
RP10-4815SE(3,4) 36-75 15 670 241 87 470
RP10-1205DE(3,4)
9-18
±5 ±1000 992
84
±680
RP10-1212DE(3,4) 9-18 ±12 ±416 1002 83 ±330
RP10-1215DE(3,4) 9-18 ±15 ±333 991 84 ±110
RP10-2405DE(3,4) 18-36 ±5 ±1000 502 83 ±680
RP10-2412DE(3,4)
18-36
±12 ±416 489
85
±330
RP10-2415DE(3,4)
18-36
±15 ±333 496
84
±110
RP10-4805DE(3,4) 36-75 ±5 ±1000 248 84 ±680
RP10-4812DE(3,4)
36-75
±12 ±416 242
86
±330
RP10-4815DE(3,4) 36-75 ±15 ±333 245 85 ±110
Notes:
Note1: Maximum value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.
Model Numbering
RP10-__ __ _E/_ _
Input Voltage
Package(4)
Output Voltage
Control Logic(3)
Single or Dual
Ordering Expamples:
RP10-1205SE/P = 12V Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted
RP10-4805DE/M1-HC = 48V Input, 5V Output, Extended Temp. Range, No CTRL pin, Heat-sink fitted
Notes:
Note3: add suffix “M1” for higher efficiencies and extended temperature range
add suffix “P” for CTRL function with Positive Logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix -HC for premounted Heat-sink and clips
www.recom-power.com
REV.: 2/2017
UL60950-1 Certified
E196683
PD-1


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Under Voltage Lockout (UVLO)
Input Filter
Input Reflected Ripple Current(5)
Input Surge Voltage
Start-up time
Operating Frequency Range
Minimum Load (6)
Ripple and Noise
Remote ON/OFF(7)
Input current of Remote pin (CTRL)
Condition
nom. Vin = 12V
nom. Vin = 24V
nom. Vin = 48V
nominal Vin and full load
12V input, 100ms max.
24V input, 100ms max.
48V input, 100ms max.
nominal Vin and constant resistor load Power up
of full load
measured by 20MHz bandwidth
Single
Dual
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
DC-DC OFF
DC-DC ON
RP10-E
Series
Min.
9VDVC
18VDC
36VDC
270kHz
10%
-0.5mA
Typ.
12VDC
24VDC
48VDC
30mAp-p
20ms
300kHz
Max.
18VDC
36VDC
75VDC
none
Pi-Type
36VDC
50VDC
100VDC
330kHz
50mVp-p
75mVp-p
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
Short or 0V < Vr < 1.2V
Open or 3.5V < Vr < 12V
20mA
+1.0mA
Notes:
Note5: Simulated source impedance of 12μH. 12μH inductor in series with +Vin.
Note6: The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listed
specification.
Note7: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin.
If no suffix is specified, the control pin will be omitted.
RP10-1205SE
Efficiency vs. Output Current
95
90
85
80
75
70
65
60
55
50 9Vin
45
12Vin
18Vin
40
10 20 30 40 50 60 70 80 90 100
Output Current [%]
Efficiency vs. Input Voltage
85
80
75
70
65
60
55
9
10 11
12 13 14 15 16 17 18
Total Input Voltage [%]
PD-2
continued on next page
REV.: 2/2017
www.recom-power.com


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP10-E
Series
RP10-2405SE
Efficiency vs. Output Current
95
90
85
80
75
70
65
60
55
50
45
18Vin
24Vin
36Vin
40
10 20 30 40 50 60 70 80 90
Output Current [%]
100
Efficiency vs. Input Voltage
90
85
80
75
70
65
60
18 20 22 24 26 28 30 32 34 36
Total Input Voltage [%]
RP10-4805SE
Efficiency vs. Output Current
95
90
85
80
75
70
65
60
55 36Vin
50 48Vin
45 75Vin
40
10 20 30 40 50 60 70 80 90 100
Output Current [%]
Efficiency vs. Input Voltage
86
84
82
80
78
76
74
36 40 44 48 52 56 60 66 72 75
Total Input Voltage [%]
REGULATIONS
Parameter
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
Cross Regulation
Transient Response recovery time
www.recom-power.com
Condition
low line to high line
0% to 100% load
Single
Dual
asymmetrical 25%<>100% load
25% load step change
REV.: 2/2017
Value
±1%
±0.2%
±0.5%
±1.0%
±5%
250μs typ.
PD-3


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Condition
3.3Vout
Zener Diode Clamp
5Vout
12Vout
15Vout
% of Iout rated
I/P to O/P
I/P (O/P) to case
500VDC
RP10-E
Series
Value
continuous, automatic recovery
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
150% max.
1.6kVDC/1 minute
1.6kVDC/1 minute
1Gmin.
300pF max.
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.
ENVIRONMENTAL
Parameter
Operating Temperature Range
(Reference Derating Curve)(9)
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
MTBF(10)
Derating Graph(9,11)
100
Condition
Standard with derating
M1 with derating
vertical direction by natural convection (20LFM)
without Heat-Sink
with Heat-Sink
non-condensing
RP10-4805SE
MIL-HDBK-217F, Full Load
RP10-4805SE with Heat-sink
100
Value
-25°C to +100°C
-40°C to +85°C
+105°C
±0.02%/°C max.
12°C/Watt
10°C/Watt
5% - 95% RH
MIL-STD-810F
MIL-STD-810F
3342 x103 hours
80 80
PD-4
60
40
20
0
-25
-20 0
Ambient
20 40 60
Temperature
80 100
7[7°C]
continued on next page
REV.: 2/2017
60
40
20
0
-20 0 20 40 60 80 100
-25 Ambient Temperature [8°1C]
www.recom-power.com


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

RP10-E
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Series
RP10-4805SE/M1
100
RP10-4805SE/M1-HC
100
80 80
60 60
40 40
20 20
0
-40 -20 0 20 40 60 80 100
Ambient Temperature [°8C5]
0
-40 -20 0 20 40 60 80 100
Ambient Temperature [°C88]
Notes:
Note9: M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
Note10: BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com.
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
UL General Safety
Report / File Number
E196683
Standard
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance
Condition
Standard / Criterion
EMI Standard(12)
with external filter
EN55022, Class A or B
ESD
Air ±8kV and Contact ± 6kV
C2 EN61000-4-2, Criteria B
Radiated Immunity
Fast Transient(13)
Surge(13)
Conducted Immunity
10 V/m
±2kV
±2kV
10 Vr.m.s
Fuse
Input
+VIN
C1
+VOUT
DC
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
DC
Notes:
-VOUT
-VIN
Note12: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below.
Note13: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5C3. The filter capacitor
Recom suggests: Nippon chemi-con KY series, 220μF/100V.
EMI Filtering Class A
C2
C2
Fuse
Input
+VIN
C1
DC
-VIN
+VOUT
DC
-VOUT
Fuse
Input
+VIN
C1
DC
-VIN
+VOUT
DC
COM
-VOUT
Fuse
Input
C3
MODEL
C2
RP10-12xxS_DE
+VOUT
RP10+V-IN24xxS_DEDC
C1
COM
RP10-48DxxCS_DE
-VOUT
-VIN
www.recom-power.com
C3
C1 C2
2.2μF/25V
1206 MLCC
1000pF/2kV
1808 MLCC
N/A
1000pF/2kV
1808 MLCC
N/A
1000pF/2kV
1808 MLCC
continued on next page
REV.: 2/2017
C3
C3
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
PD-5


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Fuse L1
Input
C1
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
EMI Filtering Class B
Fuse
Input
L1
C1
C3
+VIN
C2
DC
-VIN
+VOUT
DC
-VOUT
Fuse
Input
L1
C1
MODEL
Fuse
Input
RP10-12xxLS1_DE
C1
RP10-24xxS_DE
RP10-48xxS_DE
C4
C1
C3
3.3μF/50V
1812 MLCC+VOUT
+VIN
DC
C2 2.2μF/50VCOM
1D8C12 MLCC
-VOUT
-VIN
2.2μF/100V
1812 MLCC
C4
C2
N/A
N/A
2.2μF/100V
1812 MLCC
C3/C4
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
C3
RP10-E+VIN
+VOUT
DC
C2
SeriesDC
-VOUT
-VIN
C4
C3
+VIN
C2
DC
-VIN
+VOUT
DC
COM
-VOUT
C4
L1
CMC: 325μH
ref: WE 744290321
ref.: CMC-06
CMC: 325μH
ref: WE 744290321
ref.: CMC-06
CMC: 325μH
ref: WE 744290321
ref.: CMC-06
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimensions (LxWxH)
Package Weight
Dimension Drawing (mm)
Type
Case
Base
Potting
without Heat-sink
with Heat-sink
without Heat-sink
with Heat-sink
Value
Nickel coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
27g
37.89g
50.8
15.20
20.32
1
Bottom View
2
6
3
4
5
25.4
Ø1.0
Recommended Footprint Details
Ø1.3 +0.15/-0
2.54
Pin Connections
Pin # Single
Dual
1 +Vin +Vin
2 -Vin -Vin
3
+Vout
+Vout
4
No Pin
Com
5 -Vout -Vout
6 CTRL CTRL
Pin Pitch Tolerance ±0.25mm
Pin dimension tolerance ±0.1mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
PD-6
continued on next page
REV.: 2/2017
www.recom-power.com


RP10-2415DE (RECOM)
DC/DC Converter

No Preview Available !

Click to Download PDF File for PC

DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
Dimension Drawing (mm) with Heat-sink
50.00
Top View
Heat-sink
1.40 1.30
15.20
ø1.0
20.30
56.80
PACKAGING INFORMATION
Parameter
Packaging Quantity
Storage Temperature Range
Storage Humidity
Type
without Heat-sink Tube
with Heat-sink Tray
RP10-E
Series
25.4
2.50
5.10
Value
9pcs.
20pcs.
-55°C to +125°C
5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2017
PD-7




RP10-2415DE.pdf
Click to Download PDF File