AM2L-NZ (AIMTEC)
DC-DC Converter

No Preview Available !

Click to Download PDF File for PC

FEATURES:
Click on Series name for product info on aimtec.com
Series AM2L-NZ
2 Watt | DC-DC Converter
Low Profile SMD (Surface Mount Device) MTBF>1,000,000 hours
1000VDC & 6000VDC Isolation
Operating temperature: -40°C to +85°C
Industry Standard Pinout
High Efficiency up to 85%
Unregulated Single, Dual, Dual Separated Output Models
Models
Single output
Model
AM2L-0515S-NZ
*AM2L-1205S-NZ
*AM2L-1212S-NZ
AM2L-0505SH60-NZ
AM2L-1205SH60-NZ
AM2L-1215SH60-NZ
AM2L-2405SH60-NZ
AM2L-2412SH60-NZ
AM2L-2415SH60-NZ
Input Voltage(V)
4.5-5.5
10.8-13.2
10.8-13.2
4.5-5.5
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
Output Voltage
(V)
15
5
12
5
5
15
5
12
15
Output Current
max(mA)
133
400
167
400
400
133
400
167
133
Isolation
(VDC)
1000
1000
1000
6000
6000
6000
6000
6000
6000
Efficiency
(%)
84
82
85
77
78
81
79
82
80
Models
Dual output
Model
AM2L-0505D-NZ
*AM2L-0509D-NZ
AM2L-0512D-NZ
*AM2L-0515D-NZ
*AM2L-1205D-NZ
*AM2L-1209D-NZ
*AM2L-1212D-NZ
AM2L-1215D-NZ
Input Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
Output Voltage
(V)
±5
±9
±12
±15
±5
±9
±12
±15
Output Current
max (mA)
±200
±111
±83
±67
±200
±111
±83
±67
Isolation
(VDC)
1000
1000
1000
1000
1000
1000
1000
1000
Efficiency
(%)
82
83
84
82
83
84
84
85
Models
Dual Separated output
Model
Input Voltage Output Voltage Output Current
(V) (V) max (mA)
Isolation
(VDC)
Efficiency
(%)
*AM2L-050505D-NZ
4.5-5.5
5/5
200/200
1000
82
*AM2L-120505D-NZ
10.8-13.2
5/5
200/200
1000
82
*AM2L-121515D-NZ
10.8-13.2
15/15
67/67
1000
85
*Not recommended for new design
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-26.4
Maximum
Units
VDC
www.aimtec.com
F 051e R12.Q
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only


AM2L-NZ (AIMTEC)
DC-DC Converter

No Preview Available !

Click to Download PDF File for PC

Isolation Specifications
Parameters
Tested I/O voltage
Tested V1 output/ V2 output
Capacitance V input/V output
Capacitance V1 output/V2 output
Resistance
Conditions
60 sec
60 sec
500VDC
500VDC
500Vdc
Typical
1000
10
10
>1000
Series AM2L-NZ
2 Watt | DC-DC Converter
Rated
1000, 6000
Units
VDC
VDC
pF
pF
MOhm
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See Tolerance Graph
±5
%
Short Circuit protection
1000VDC Momentary
6000VDC Continuous
1 sec
Short Circuit Restart
Auto-Recovery
Line voltage regulation
For a 1% change of Vin
±1.2
%
Load voltage regulation (5 Vout)
12.8
Load voltage regulation (9 Vout)
Load voltage regulation (12 Vout)
From 10% load to 100% load
8.3
6.8
%
Load voltage regulation (15 Vout)
Temperature coefficient
At 100% load
6.3
±0.03
%/oC
Ripple & Noise*
20MHz Bandwidth
150
mV p-p
Minimum Load Current**
10 % of Max
*Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available on Aimtec’s website www.aimtec.com
**If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
Conditions
Typical
Maximum
Units
100% load, nominal input
-40 to + 85
-55 to + 125
100
100
KHz
oC
oC
oC
Free Air Convection
95 % RH
Plastic(UL94-V0)
1000VDC
6000VDC
2.1
3.8
g
Single, Dual, Dual Separated 1000VDC 0.70 x 0.70 x 0.24 inches 17.78 x 17.78 x 6.00 mm
Single 6000VDC
0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm
>1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC)
1.5mm from case for 10 seconds
260
oC
Safety Specifications
Parameters
Agency approvals
Standards
CE (for 6000VDC isolation models)
EN 60601-1-1; EN 60601-1-2
www.aimtec.com
F 051e R12.Q
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only


AM2L-NZ (AIMTEC)
DC-DC Converter

No Preview Available !

Click to Download PDF File for PC

Pin Out Specifications
1000VDC
Pin Single
Dual
1 -Vin - Vin
2 + Vin
+ Vin
5 NC -Vout
6
- Vout
Common
7 +Vout
+Vout
8 NC
NC
9 NC
NC
10 NC -Vout
12 NC
NC
13 NC
NC
14 NC
NC
Dual
Separated
- Vin
+ Vin
-V1out
+V1out
NC
NC
+V2out
-V2out
NC
NC
NC
NOTE: On dual output models Pin 5 and Pin 10 are connected internally together.
Either Pin 5 or Pin 10, or both can be used as the -Vout
NC: not connected
Series AM2L-NZ
2 Watt | DC-DC Converter
6000VDC
Pin Single
1 - V in
2 No Pin
3 No Pin
4 No Pin
5 No Pin
6 No Pin
7 NC
8 NC
9 +V out
10 -V out
11 No Pin
12 No Pin
13 No Pin
14 No Pin
15 No Pin
16 +V in
Dimensions
1000VDC
Side View
17.78
(0.70)
6.00 5.75
(0.24) (0.23)
1.27
(0.05)
2.54
(0.10)
Top View
1.00
(0.04)
17.78
(0.70)
2.00
(0.08)
2.54
(0.10)
14 13 12
10 9
8
2.75
(0.11)
17.78 12.70
(0.70) (0.50)
Front View
A
A
0.25
(0.01)
0.25
(0.01)
1.30 ±0.13
(0.05 ±0.005) MAX
5.00º angle
1 23
56
7
www.aimtec.com
F 051e R12.Q
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only


AM2L-NZ (AIMTEC)
DC-DC Converter

No Preview Available !

Click to Download PDF File for PC

Dimensions
6000VDC
Side View
23.86
(0.94)
8.00 7.50
(0.32) (0.30)
18.50 13.70
(0.73) (0.54)
3.04 2.54
(0.12) (0.10)
Top View
1.00
(0.04)
2.00
(0.08)
16 10 9
1 78
15.24
(0.60)
Front View
A
13.10
(0.52)
18.50
(0.73)
A
0.50
(0.01)
5.00º
1.35 ± 0.13 angle
(0.05 ± 0.005) MAX
Series AM2L-NZ
2 Watt | DC-DC Converter
+10%
+5%
Tolerance Envelope Graph
Typical Load Line
+2.5%
-2.5%
-7.5%
10%
50%
100%
Output Current(%)
www.aimtec.com
F 051e R12.Q
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only


AM2L-NZ (AIMTEC)
DC-DC Converter

No Preview Available !

Click to Download PDF File for PC

Recommended Filter Circuit
+ Vin
L
Single Output
Cin +
DC DC
- Vin
L
+Vout + Vin
L
+Cout
Cin +
- Vin
- Vin
Series AM2L-NZ
2 Watt | DC-DC Converter
Dual Output
DC DC
L
+Vout
+
Cout
Common
+
L Cout
-Vout
+ Vin
L
Cin +
- Vin
Dual Separated Output
DC DC
L
+V1output
+ Cout
-V1 output
L
+ Cout
+V2 output
-V2 output
If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the
converter (see above).
It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC
converter switching frequency to avoid mutual interference.
The capacitance of the outputfilter capacitor must not exceed the values in the Table below to avoid startup problems and
ensure safe and reliable operation.
It’s not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5
watt.
External Capacitor Tables
Input Capacitor (Cin)
Output Capacitor (Cout)
Vin
(VDC)
5
12
24
Cin
(uF)
4.7
2.2
1
Single
Vout
(VDC)
5
9
12
15
Cout
(uF)
10
4.7
2.2
1
Dual
Vout
(Vdc)
±5
±9
±12
±15
Cout
(uF)
4.7
2.2
1
0.47
Dual
Separated
Vout (Vdc)
5/5
9/9
12/12
15/15
Cout
(uF)
4.7
2.2
1
0.47
Overload Protection
The output circuit of these products has no protection against overload. It is recommended to install external overload
protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input.
To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the
AM2LV-NZ series as an alternative.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.Q
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only




Click to Download PDF File