TFS125L
Vectron International

Part Number TFS125L
Description VI TELEFILTER
Page 5 Pages

TFS125L datasheet pdf
View PDF for PC
TFS125L pdf
View PDF for Mobile


No Preview Available !

Filename: tfs 125l.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23 °C
0 dBm
650 || -14,5 pF
750 || -12,8 pF
TFS 125L
15.10.2004
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 125L is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 125 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae 5,7 dB
min. 7 dB
Nominal frequency
fN -
125 MHz
Passband
Pass band ripple
fN
± 200
kHz
-
max.
1 dB
Relative attenuation
fN
fN ±
fN ±
fN ±
fN ±
fN ±
fN ±
fN -
fN +
0,6
1,2
1,8
3,4
6,5
9,5
115
17
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Group delay
… fN
… fN
… fN
… fN
… fN
… fN
… fN
… fN
… fN
±
±
±
±
±
±
±
-
+
arel
200 kHz
1,2
1,8
3,4
6,5
9,5
17
17
325
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
at fN
0,6 dB
11 dB
30 dB
35 dB
45 dB
55 dB
60 dB
75 dB
75 dB
1,1 µs
max.
min.
min.
min.
min.
min.
min.
min.
min.
max.
min.
1 dB
8 dB
20 dB
25 dB
34 dB
40 dB
43 dB
55 dB
55 dB
1,7 µs
0,7 µs
Group delay ripple within PB
60 ns
max. 120 ns
VSWR
1,5
max.
2,3
Input power level
-
max.
10 dBm
Operating temperature range
OTR
-
- 10 °C ... + 85 °C
Storage temperature range
- - 40 °C ... + 85°C
Frequency inversion temperature
37 °C
-
Temperature coefficient of frequency
TCf **
-0,04 ppm/K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
www.DataSheet4U.net



No Preview Available !

Filename: tfs 125l.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 125L
15.10.2004
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-101000 105 110 115 120 125 130 135 140 145 150
frequency in MHz
Construction and pin connection
(All dimensions in mm)
13,3 ±0,2
TFS 125L
S42
1 1,0±0,2 5
Date code
0 1.59
-1 1.53
-2 1.47
-3 1.41
-4 1.35
-5 1.29
-6 1.23
-7 1.17
-8 1.11
-9 1.05
-11024.5 124.6 124.7 124.8 124.9 125 125.1 125.2 125.3 125.4 1250..599
frequency in MHz
1 Input RF Return
2 Ground
3 Ground
4 Ground
5 Output
6 Output RF Return
7 Ground
8 Ground
9 Ground
10 Input
1,91±0,2
10 7,62±0,2
6
Date code:
S
T
U
...
Year + week
2004
2005
2006
50 Test circuit
L1
C1
10 5
16
2, 3, 4, 7, 8, 9
L2
C2
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

Filename: tfs 125l.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 125L
15.10.2004
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Tape (all dimensions in mm)
W : 24,00 +0,30/-0,10
Po : 4,00 ± 0,1
Do : 1,50 +0,1/-0
E : 1,75 ± 0,10
F : 11,50 ± 0,10
G(min) : 0,60
P2 : 2,00 ± 0,1
P1 : 12,00 ± 0,1
D1(min) : 1,50
Ao : 7,10 ± 0,10
Bo : 13,90 ± 0,10
Ct : 21,5 ± 0,1
Reel (all dimensions in mm)
A :330
W1 : 24,4 +2/-0
W2(max) : 30,4
N(min) : 60
C : 13,0 +0,5/-0,2
t
Ko
A
Pull Off Direction
P1
Do
Date Code
Po
P2
Typ PIN Marker
W2
D1
Ao
C
N
The minimum bending radius is 45 mm.
W1
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

Filename: tfs 125l.doc
VI TELEFILTER
Air reflow temperature conditions
Version 1.2
Filter specification
TFS 125L
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to 255°C
All temperatures shown are +5/-0°C.
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 90 and 150 seconds
255°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
15.10.2004
4/5
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.




TFS125L datasheet pdf
Download PDF
TFS125L pdf
View PDF for Mobile


Similiar Datasheets : TFS120 TFS1200 TFS120A TFS120C TFS120E TFS121 TFS121B TFS1220 TFS1220B TFS1237 TFS124 TFS125A TFS125B TFS125C TFS125D TFS125G TFS125H TFS125K TFS125L

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact