Version 1.2
Filter Specification TFS 125K
18.06.2003
1/5
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedances : 50
C
dBm
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the
pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative
attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is
included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
ae
(Reference level)
Nominal frequency
fN
1 dB band width
BW
Pass band ripple within 100KHz
Relative attenuation
fN
arel
150 kHz
1,88 dB
-
2,80 MHz
0,10 dB
-
2,5 1,0 dB
125 MHz
300 kHz
max. 0,20 dB
max. 1 dB
fN - 14
fN - 28
fN + 14
fN + 23
fN + 33
VSWR
fN - 150
MHz... fN -
MHz... fN -
MHz... fN +
MHz... fN +
MHz... fN +
kHz ... fN +
28 MHz
124 MHz
23 MHz
33 MHz
325 MHz
150 kHz
50
65
40
55
42
1.3:1
dB
dB
dB
dB
dB
Absolute group delay
fN - 150 kHz ... fN +
Group delay ripple
fN - 150 kHz ... fN +
Intermodulation
GD*)
150 kHz
GDR *)
150 kHz
**)
245 ns
15 ns
IP3
Input power level
54 dB
Temperature coefficient of frequency
Operating temperature range
TCf ***)
- 72
-
ppm/K
Storage temperature range
*) measured with smoothing; smoothing aperture 50 kHz
**) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal:
***) f(Hz) = TCf(ppm/K) x ( T) x fTo(MHz)
fN - 14 MHz
min. 5
min. 12
min. 30
min. 44
min. 38
dB
dB
dB
dB
dB
max 2 : 1
max. 300 ns
max. 100 ns
min. 45 dB
max 10 dBm
-
- 10 °C ... + 85 °C
- 30°C ... + 85 C
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
www.DataSheet4U.net



No Preview Available !

TFS125K.doc
VI TELEFILTER
Version 1.2
Filter Specification TFS 125K
Construction and pin connection
(All dimensions in mm)
9,3 Max.
876
9
TFS125K
10
5
4
1 2 3 Date code
1 Ground
2 Ground
3 Ground
4 Ground
5 Output
6 Ground
7 Ground
8 Ground
9 Ground
10 Input
18.06.2003
2/5
2,54 ±0,12,54 ±0,1
0,10
123
10 4
95
87 6
0,8
7,1
Date code: Year+week
N 2001
P 2002
R 2003
...
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

TFS125K.doc
VI TELEFILTER
Version 1.2
Filter Specification TFS 125K
18.06.2003
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
W : 16 ± 0,3
Po : 4 ± 0,1
Do : 1,5 + 0,1
E : 1,75 ± 0,1
F : 7,5 ± 0,1
G (min) :
P2 :
0,6
2 ± 0,1
P1 : 8 ± 0,1
D1(min) : 1,5
Ao : 5,3 ± 0,1
Bo : 9,7 ± 0,1
CT : 13,5 + 0,1
CT
Reel (all dimensions in mm):
A:
W1 :
W2 (max) :
N (min) :
C:
330
16,4 +2
22,4
50
13 + 0,5 / - 0,2
COVER TAPE
EMBOSSED CARRIER TAPE
Do Po
P2
Ao
D1
Bo
E
F
W
G
P1
W2
C
A
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

TFS125K.doc
VI TELEFILTER
Air reflow temperature conditions
Version 1.2
Filter Specification TFS 125K
18.06.2003
4/5
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20 40 60 80 100 120 140 160 180 200 220 240
time / sec.
Table for temperature vs. time during the air reflow process
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Tolerance of temperatures: ± 5 °C
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.




TFS125K datasheet pdf
Download PDF
TFS125K pdf
View PDF for Mobile


Similiar Datasheets : TFS120 TFS1200 TFS120A TFS120C TFS120E TFS121 TFS121B TFS1220 TFS1220B TFS1237 TFS124 TFS125A TFS125B TFS125C TFS125D TFS125G TFS125H TFS125K TFS125L

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact