Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23 °C
0 dBm
1080 || -7,4 pF
1250 || -6,7 pF
TFS 120E
27.07.2006
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 120E is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 120 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
Nominal frequency
Centre frequency
ae
fN
fC
1 dB Passband
Relative attenuation
fN
fN ±
fN ±
fN ±
fN ±
... fN ±
0,3 MHz ... fN ±
0,5 MHz ... fN ±
0,7 MHz ... fN ±
1 MHz ... fN ±
Group delay ripple within PB
0,1
0,5
0,7
1
80
PB
arel
MHz
MHz
MHz
MHz
MHz
Input power level **
Permissible DC voltage between any two terminals
6 dB
-
120 MHz
290 kHz
0,5
15
32
39
48
650
dB
dB
dB
dB
dB
ns
max.
7 dB
120
-
fN ± 100
MHz
kHz
max.
min.
min.
min.
min.
max.
max.
max.
1
10
25
35
45
1000
18
10
dB
dB
dB
dB
dB
ns
dBm
V
Operating temperature range
OTR
-
- 35 °C ... + 85 °C
Storage temperature range
- - 40 °C ... + 85 °C
Frequency inversion temperature
29 °C
Temperature coefficient of frequency
TCf ***
-0,04 ppm/K²
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.10dBm only
***) f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
www.DataSheet4U.net



No Preview Available !

Filename: tfs 120e.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 120E
27.07.2006
2/5
Filter characteristic
0
-8
-16
-24
-32
-40
-48
-56
-64
-72
1-8107.607
118.0856 118.5642 119.0428 119.5214 120 120.4786 120.9572 121.4358 121.9144
frequency in MHz
122.393
0 8.88
-1 8.13
-2 7.38
-3 6.63
-4 5.88
-5 5.13
-6 4.38
-7 3.63
-8 2.88
-9 2.13
-11109.75
119.8
119.85
119.9
119.95 120 120.05
frequency in MHz
120.1
120.15
120.2
120.12.538
Construction and pin connection
(All dimensions in mm)
13,3 ±0,2
TFS 120E
Date code
1 Input
2 Ground
3 Ground
4 Ground
5 Output
6 Output
7 Ground
8 Ground
9 Ground
10 Input
1 1,0±0,2 5
1,91±0,2
10 7,62±0,2
6
Date code:
U
V
W
...
Year + week
2006
2007
2008
200 Test circuit
L1
C1
L2
1
10 SAW
5
6
2, 3, 4, 7, 8, 9
L
C
L
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

Filename: tfs 120e.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 120E
27.07.2006
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Tape (all dimensions in mm)
W : 24,00 +0,30/-0,10
Po : 4,00 ± 0,1
Do : 1,50 +0,1/-0
E : 1,75 ± 0,10
F : 11,50 ± 0,10
G(min) : 0,60
P2 : 2,00 ± 0,1
P1 : 12,00 ± 0,1
D1(min) : 1,50
Ao : 7,10 ± 0,10
Bo : 13,90 ± 0,10
Ct : 21,5 ± 0,1
Reel (all dimensions in mm)
A :330
W1 : 24,4 +2/-0
W2(max) : 30,4
N(min) : 60
C : 13,0 +0,5/-0,2
t
Ko
A
Pull Off Direction
P1
Date Code
Do Po P2
Typ PIN Marker
D1
W2
Ao
C
N
The minimum bending radius is 45 mm.
W1
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.



No Preview Available !

Filename: tfs 120e.doc
VI TELEFILTER
Air reflow temperature conditions
Version 1.2
Filter specification
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
TFS 120E
27.07.2006
4/5
Temperature / °C
Chip-mount air reflow profile
max. 260°C
217°C
max. 300 s
10 ... 30 s
30 ... 150 s
Time / s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.




TFS120E datasheet pdf
Download PDF
TFS120E pdf
View PDF for Mobile


Similiar Datasheets : TFS120 TFS1200 TFS120A TFS120C TFS120E TFS121 TFS121B TFS1220 TFS1220B TFS1237 TFS124 TFS125A TFS125B TFS125C TFS125D TFS125G TFS125H TFS125K TFS125L

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact