T1K-16TA Datasheet PDF - ETC

www.Datasheet-PDF.com

T1K-16TA
ETC

Part Number T1K-16TA
Description (T1K16TA / T1K08TA) Discrete AC Output Modules
Page 6 Pages


T1K-16TA datasheet pdf
Download PDF
T1K-16TA pdf
View PDF for Mobile

No Preview Available !

Terminator I/O Specifications
AC OUTPUT MODULES
T1K-08TA <--->
T1K-16TA <--->
8-point and 16-point,
AC output modules
The 8-point AC module uses a T1K-08B
or T1K-08B-1 base, which is purchased
separately.
The 16-point AC module uses a
T1K-16B or T1K-16B-1 base, which is
purchased separately.
Specifications
T1K-08TA
T1K-16TA
Outputs per Module
Commons per Module
Operating Voltage Range
Output Voltage Range
Max. Load Current
ON Voltage Drop
Max. Leakage Current
Max. Inrush Current
Min. Load
OFF to ON Response
ON to OFF Response
Base Power Required
Status Indicators
Error Status
Indications(LEDs )
Fuses (User Replaceable)
T1K-FUSE-1
Weight
8 16
2 (4 pts. / common) isolated
4 (4 pts. / common) isolated
17-240 VAC (47-63Hz) min./max.
15-264 VAC (47-63Hz) min./max.
1A / pt., 4A / common (subject to derating)
1.5VAC @ > 50mA, 4.0VAC @ < 50mA
4mA @ 264 VAC
10A for 10ms
10mA
< 1ms
< 1ms + 1/2 cycle
250mA @ 5VDC
450mA @ 5VDC
Logic side
FU1 ON = fuse 1 blown
FU2 ON = fuse 2 blown
FU1/FU2 ON = fuse 1 or 2 blown
FU3/FU4 ON = fuse 3 or 4 blown
2, (10A, 250V / common)
5 x 20 mm type
4, (10A, 250V / common)
5 x 20 mm type
140g 190g
Equivalent Output Circuit
www.DataSheet4U.com
w w w. a u t o m a t i o n d i r e c t . c o m / f i e l d I O
Universal Field I/O 7–41



No Preview Available !

Terminator I/O Dimensions and Installation
DIMENSIONS AND INSTALLATION
It is important to understand the instal-
lation requirements for your Terminator
I/O system. This will help ensure that the
Terminator I/O products work within
their environmental and electrical limits.
Plan for safety
This catalog should never be used as a
replacement for the technical data sheet
that comes with the products or the
T1K-INST-M Installation and I/O
Manual (It is also available online at
www.automationdirect.com.) The tech-
nical data sheet contains information
that must be followed. The system instal-
lation should comply with all appro-
priate electrical codes and standards.
Unit dimensions and
mounting orientation
Use the following diagrams to make sure
the Terminator I/O system can be
installed in your application. Terminator
I/O units can be mounted horizontally
or vertically. However, to insure proper
airflow for cooling purposes, units
should not be mounted upside-down. It
is important to check the Terminator I/O
dimensions against the conditions
required for your application. For
example, it is recommended to leave 2”
depth for ease of access and cable clear-
ance. However, your distance may be
greater or less. Also, check the installa-
tion guidelines for the recommended
cabinet clearances.
See
the Enclosures section
of this desk reference for an
enclosure that may be suitable
for your application
Terminator I/O Environmental Specifications
Ambient Operating Temperature
Storage Temperature
Ambient Humidity
Atmosphere
Vibration Resistance
Shock Resistance
Voltage Withstand (Dielectric)
Insulation Resistance
32°F to 131°F (0°C to 55°C)
-4°F to 158°F (-20°C to 70°C)
5% to 95% (Non-condensing)
No corrosive gases. The level of environmental
pollution = 2 (UL 840)
MIL STD 810C, Method 514.2
MIL STD 810C, Method 516.2
1500VAC, 1 minute
500VDC, 10M
Noise Immunity
NEMA ICS3-304
Impulse noise 1µs, 1000V
FCC class A
RFI (144MHz, 430MHz 10W, 10cm)
Agency Approvals
UL, CE, FCC class A, NEC Class 1 Division 2
48mm
(1.89in)
48mm
(1.89in)
48mm
(1.89in)
89mm
(3.5in)
83.3mm
(3.28in)
80mm
(3.15in)
80mm
(3.15in)
80mm
(3.15in)
80mm
(3.15in)
Power Supply
Network Interface Module
7–14 Universal Field I/O
Half-size I/O Module
with Base
Full-size I/O Module
with Base
System Depth
1 - 8 0 0 - 633 - 0 4 05



No Preview Available !

I/O MODULE
I/O module
installation
Terminator I/O modules feature separate
terminal bases for easy installation.
To install I/O modules:
1. Slide the module into its terminal base (until
it clicks into position)
2. Hook upper DIN-rail tabs over the top of DIN-
rail, and press the assembly firmly onto the
DIN-rail.
3. Slide the module along the DIN-rail until it
engages with the adjacent module.
1
2
Terminator I/O Installation
DN-ASB
angled mounting bracket
Great for mounting
in upper locations
Great for mounting
in lower locations
Optional angled support bracket raises
and tilts the mounting rail for easier
access and wiring. Use with 35mm
DIN rail. See the Connection Systems
in this catalog for details.
3
Removing I/O
modules is a snap
Grip the locking handle, as
shown, and pull gently to
eject the I/O module from
its base. The module will
slide out for easy replace-
ment. This procedure does
not apply to network interface
modules or power supplies,
which have integral bases.
w w w. a u t o m a t i o n d i r e c t . c o m / f i e l d I O
Hot swappable
I/O modules
You can remove I/O modules
under power, but exercise
caution while doing so. Do
not touch the terminals with
your hands or any conduc-
tive material. Always remove
power when possible.
Universal Field I/O 7–15



No Preview Available !

Terminator I/O Specifications
POWER SUPPLIES AND POWER REQUIREMENTS
Power supplies
The Terminator I/O
product line offers two
power supply options:
AC or DC. The power
supplies are always posi-
tioned to the left of the
modules to which they
supply power. Consult
the system configura-
tion examples and the
power
budgeting
example for more informa-
tion on positioning power supplies.
Power supply
specifications
Power Supply
Specifications
Input Voltage
Range
Input Frequency
Maximum Power
110/220VAC 12/24VDC
50/60Hz
50VA
N/A
30W
Max. Inrush Current 20A
10A
Insulation
Resistance
> 10M@ 500VDC
1 min. @ 1500VAC between
Voltage Withstand primary, secondary and field
ground
5VDC
PWR
Voltage
5.25VDC 5.25VDC
2000 mA max
Current
Rating
(see current
option note
2000 mA max
below)
Ripple
5% max. 5% max.
Voltage
24VDC
N/A
24VDC
PWR
Current
Rating
300mA max.
(see current
option note
below)
Ripple
10% max.
N/A
N/A
Fuse 1 (primary), not replaceable
Note: 500mA @ 24VDC can be achieved by lowering
the 5VDC from 2000mA to 1500mA .
Power requirements
Module 5VDC 24VDC Module 5VDC 24VDC Module 5VDC 24VDC
Interface Modules
T1H-EBC
350
T1H-EBC100
300
T1H-PBC
530
T1K-DEVNETS 250
T1K-RSSS
250
T1K-MODBUS 300
DC Input Modules
T1K-08ND3
35
T1K-16ND3
70
AC Input Modules
T1K-08NA-1
35
T1K-16NA-1
70
DC Output Modules
Analog Input Modules
0 T1H-08TDS 200
0
T1F-08AD-1
75 50*
0 T1K-08TD1
100
200*
T1F-08AD-2
75 50*
0 T1K-16TD1
200
400*
T1F-16AD-1
75 50*
45 T1K-08TD2-1 200
0
T1F-16AD-2
75 50*
0 T1K-16TD2-1 200
0
T1F-14THM
60 70*
0 AC Output Modules
T1F-16RTD
150 0
T1K-08TA
250 0
Analog Output Modules
0 T1K-16TA
450 0
T1F-08DA-1
75 75*
0 T1K-08TAS 300 0
T1F-08DA-2
75 75*
Relay Output Modules
T1F-16DA-1
75 150*
0 T1K-08TR
350 0
T1F-16DA-2
75 150*
0 T1K-16TR
700 0
Combination Analog Modules
T1K-08TRS 400 0
T1F-8AD4DA-1 75
60*
Specialty Modules
T1F-8AD4DA-2 75
70*
T1H-CTRIO 400 0
* Use either internal or external source
for 24VDC
* Use either internal or external source
for 24VDC
Calculating the power budget
To calculate the power budget, read the
available power (current rating) from the
Power Supply Specifications table and
subtract the power consumed by each
module to the right of the power supply.
Do not include modules to the right of
an additional power supply.
Adding additional
power supplies
Each power supply furnishes power only
to the network interface and I/O
modules to its right. Inserting a second
power supply closes the power loop for
the power supply to the left, while also
powering the modules to its right.
Perform a power budget calculation for
each power supply in the system.
Power Budget Example
Module
5VDC
24VDC
T1K-01AC
+2000mA
+300mA
T1H-EBC
-350mA
-0mA
T1K-16ND3
-70mA
-0mA
T1K-16TD2
-200mA
-0mA
T1F-08AD-1
-75mA
-50mA
Remaining
+1305mA
+250mA
Accessories
available for Terminator I/O are
listed in the Terminator Field I/O
section of the Price List
7–16 Universal Field I/O
This power supply powers the network interface module and This power supply powers these three I/O
the next two I/O modules
modules
1 - 8 0 0 - 633 - 0 4 05



T1K-16TA datasheet pdf
Download PDF
T1K-16TA pdf
View PDF for Mobile


Related : Start with T1K-16T Part Numbers by
T1K-16TA (T1K16TA / T1K08TA) Discrete AC Output Modules T1K-16TA
ETC
T1K-16TA pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact