JDP2S02ACT Datasheet PDF - Toshiba Semiconductor


www.Datasheet-PDF.com

JDP2S02ACT
Toshiba Semiconductor

Part Number JDP2S02ACT
Description UHF~VHF Band RF Switch Applications
Page 4 Pages

JDP2S02ACT datasheet pdf
View PDF for PC
JDP2S02ACT pdf
View PDF for Mobile


No Preview Available !

TOSHIBA Diode Silicon Epitaxial PIN Type
JDP2S02ACT
UHF~VHF Band RF Switch Applications
Suitable for reducing set’s size as a result from enabling high-density
mounting due to 2-pin small packages.
Low series resistance: rs = 1.0 Ω (typ.)
Low capacitance: CT = 0.3 pF (typ.)
1
JDP2S02ACT
www.DataSheet4U.com
Unit:mm
Absolute Maximum Ratings (Ta = 25°C)
2
0.6±0.05
0.05±0.03 0.5±0.03
Characteristics
Reverse voltage
Symbol
VR
Rating
30
Unit
V
1:Cathode
2:Anode
Forward current
Junction temperature
IF 50 mA
Tj 150 °C CST2
Storage temperature range
Tstg
55~150
°C
Note: Using continuously under heavy loads (e.g. the application of high
temperature/current/voltage and the significant change in
temperature, etc.) may cause this product to decrease in the
JEDEC
JEITA
TOSHIBA
1-1P1A
reliability significantly even if the operating conditions (i.e. operating Weight: 0.00077 g(Typ.)
temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Electrical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Reverse voltage
VR IR = 10 μA
Reverse current
IR VR = 30 V
Forward voltage
VF IF = 50 mA
Capacitance(Note2)
CT VR = 1 V, f = 1 MHz
Series resistance
rs IF = 10 mA, f = 100 MHz
Note1: Signal level when capacitance is measured. Vsig = 100 mVrms
Marking
Min Typ. Max Unit
30 ⎯ ⎯ V
⎯ ⎯ 0.1 μA
0.9 0.94 V
0.3 0.4 pF
1.0 1.5 Ω
Cathode
02
1
Part Number
2007-11-01



No Preview Available !

JDP2S02ACT
Note2: This package has 2 exposed electrodes on each side because of the manufacturing proceswsww.DataSheet4U.com
electrode
2 2007-11-01



No Preview Available !

TYPICAL PERFORMANCE CURVES (Ta = 25°C)
JDP2S02ACT
www.DataSheet4U.com
3 f = 1 MHz
Ta = 25°C
1
0.5
0.3
0.1
1
35
10
30 50
Reverse voltage VR (V)
0.5
100
f = 0.1 GHz
Ta = 25°C
Tester: HP4291A
1.0
1.5
10
1
0.5
0.01
1.5
1.0
0.5
f = 0.1 GHz
0.1 1 10
Forward current IF (mA)
3 2007-11-01



No Preview Available !

JDP2S02ACT
www.DataSheet4U.com
RESTRICTIONS ON PRODUCT USE
The information contained herein is subject to change without notice.
20070701-EN GENERAL
TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patents or other rights of
TOSHIBA or the third parties.
Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
4 2007-11-01




JDP2S02ACT datasheet pdf
Download PDF
JDP2S02ACT pdf
View PDF for Mobile


Similiar Datasheets : JDP2S02ACT JDP2S02ACT JDP2S02AFS JDP2S02AFS JDP2S02AS JDP2S02AS

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact