Omron

Part Number D4Sl
Description Safety interlock Switches
Page 17 Pages

D4Sl datasheet pdf
View PDF for PC
D4Sl pdf
View PDF for Mobile


No Preview Available !

Safety Interlock Switches
D4SL
D4SL
Compact 6-Contact Guard Lock
Safety-Door Switch
• Two types are available: a connector type that reduces wiring time
and a detachable terminal block type.
• Robust and durable metal head.
• Key holding force of 1,300 N.
• The wider key slot is less susceptible to movement from doors,
and can handle doors with a small radius.
• By rotating the mounting part, it is possible, both to change the
key insertion point and to enable mounting on various devices.
• Easy view LED indicators can be checked from any direction.
• By utilizing the 6-contact type, both the door open/closed status
and the solenoid ON/OFF status can be monitored independently.
• A cost-effective 5-contact model is also available.
Rev. 9.11
NEW!
Connector Type
Terminal Block Type
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EMC Directive
• EN 1088
• EN 60204-1
• GS-ET-19
Certified Standards
Certification
body
Standard
File No.
TÜV SÜD
UL *1
CQC (CCC)
EN 60947-5-1
(certified direct opening)
UL 508, CSA C22.2 No.14
GB14048.5
Consult your
representative for
details.
KOSHA *2
EN60947-5-1
*1. Certification for CSA C22.2 No. 14 is certified by the UL mark.
Certified Standard Ratings
TÜV (EN 60947-5-1)
Item Utilization category
AC-15
DC-13
Rated operating current (Ie)
1.5 A
0.22 A
Rated operating voltage (Ue)
120 V
125 V
Note: Use a 4 A fuse that conforms to IEC 60127 as a short-circuit
protection device. This fuse is not included with the switch.
G
UL/CSA (UL 508, CSA C22.2 No. 14)
C150
Rated
voltage
120 VAC
www.DataSheet.co.kr
R150
Carry
current
2.5 A
Current (A)
Make
Break
15 1.5
Rated
voltage
125 VDC
Carry
current
1.0 A
Current (A)
Make
Break
0.22
0.22
Volt-amperes (VA)
Make
Break
1,800
180
Volt-amperes (VA)
Make
Break
28 28
Solenoid Coil Characteristics
Item
Type
24 VDC
Rated operating
voltage (100% ED)
24
VDC
+10%
-15%
Current consumption*
Power ON: Approx. 34 W at 1.4 A
Constant: Approx. 2.6 W (average) at 0.4 A
(max.)
Insulation Class
Class E (120°C max.)
*A starting current is applied to the solenoid for a maximum of one
second. After this, the internal circuit switches to constant current.
Indicator Characteristics
Item
Type
Rated voltage
Current consumption
Color (LED)
LED
24 VDC
Approx. 10 mA
Orange
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
G65
Datasheet pdf - http://www.DataSheet4U.net/



No Preview Available !

D4SL Safety Interlock Switches
Specifications (continued)
Structure
Characteristics
Structure
Degree of protection *1
Durability *2
Mechanical
Electrical
Operating speed
Operating frequency
Direct opening force *4
IP67 (EN60947-5-1)
1,000,000 operations min.
150,000 operations min.
(1 A resistive load at 125 VAC) *3
0.05 to 1 m/s
5 operations/minute max.
60 N min. (EN60947-5-1)
D4SL-□□D-D4N Connector Model
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
Can be mounted
from four directions.
The switch has
a release key
on the back of
the switch as well.
Direct opening travel *4
Holding force *5
Contact resistance
Minimum applicable load *6
Rated insulation voltage (Ui)
15 mm min. (EN60947-5-1)
1,300 N min.
200 mΩ max.
1 mA resistive load at 5 VDC
(N-level reference value)
150 V (EN60947-5-1)
The switch has an
indicator on the back
of the switch as well.
Rated frequency
50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Between
terminals of
1.5 kV
G same polarity
Between
Impulse
withstand
terminals
of different
1.5 kV
voltage
polarity
(EN60947-5-1) Between other
terminals and
non-current
2.5 kV
carrying
metallic parts.
1 2 3 4 5 6 10
Notched side is No. 1
Insulation resistance
Vibration
resistance
Malfunction
100 MΩ min. (at 500 VDC)
10 to 55 Hz,
0.75 mm single
aTwmoploitpuedreation
key
holes
D4SL-□□D-D4 Terminal Block Model
www.DataSheet.co.kr
Two operation key holes
Shock
resistance
Malfunction
100 m/s2 min.
The switch has
Destrucatiroenlease ke1y ,000 m/s2­min.
CCcuoornnredvneittnio(tniIotahnl)aslhforeret-caiirrctuhiet otrchmnuerathsrlewenibttcahckas12ofw0.50eAllA. ((EENN6600994477--55--11)Cf)roamn
be mounted
four directions.
The switch has
a release key
on the back of
the switch as well.
Can be mounted
from four directions.
Ambient operating temperature
Ambient operating humidity
Weight
-10 to +55°C (with no icing)
95% max.
Approx. 360
Approx. 390
g
g
The switch has an
((CTeornmnieniocanftdlotiBhcrealomtsocworkdiotmcenhlo)thadesebwl)aecllk.
The switch has an
indicator on the back
of the switch as well.
Notes: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or
microloads. Once the contacts have been used to switch a load,
however, thy cannot be used to switch smaller loads.
The contact surfaces will become rough once they have been
used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the
standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch
box is protected from dust, oil or water penetration, do not use the D4SL
in places where cutting chips, oil, water or chemicals may enter through
the key hole on the head, otherwise Switch damage or malfunctioning may
occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an
1 2 3 4 5 6 10
ambient humidity of 40% to 70%. For further conditions, consult your sales
representative.
Notched side is No. 1
*3. Do not pass a 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. These figures are based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and
reliability level. Confirm that correct operation is possible with the actual
load beforehand.
13579
2 4 6 8 10
Two operatio
Can be m
from fou
The sw
indicato
of the s
G66
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
Datasheet pdf - http://www.DataSheet4U.net/



No Preview Available !

Structure (continued)
Structure
D4SL-NDA and D4SL-NDG
9 E1(+)
10 E2(-)
<LED>
ORANGE
2 42
4 52
8 64
41 12
51 22
63 34
76
Note: Numbers inside the boxes are
terminal numbers printed on the product.
11 1
21 3
33 5
D4SL Safety Interlock Switches
D4SL-JDG
9 E1(+)
10 E2(-)
<LED>
ORANGE
2 42
6 52
8 64
41 12
51 5
63 34
74
Note: Numbers inside the boxes are
terminal numbers printed on the product.
11 1
33 3
Operating Cycle Examples for Standard Models
D4SL-□□DA-D4(Mechanical Lock Models with Special Release Keys)
Condition 1
Condition 2
Condition 3
Turning the special
release key
G
Terminal No. and Function
E1-E2
Solenoid ON
42-11 (NC)
52-21 (NC)
Door open/closed
detection and lock
monitor contacts
31-32 (NC)
Door open/closed
detection contact
33-34 (NO)
51-52 (NC)
61-62 (NC)
63-64 (NO)
Door open/closed
detection contact
Lock monitor
contact
Lock monitor
contact
Door open.
The door will lock
when the door closes.
Door closed.
The door is locked.
www.DataSheet.co.kr
Door closed.
The door can be
opened.
Return to
condition 1
Door closed.
No power is supplied to
the solenoid.The door
is unlocked manually.
D4SL-□□DG-D4(Solenoid Lock Models with Special Release Keys)
Terminal No. and function
E1-E2
Solenoid ON
42-11 (NC)
52-21 (NC)
Door open/closed
detection and lock
monitor contacts
31-32 (NC)
Door open/closed
detection contact
33-34 (NO)
Door open/closed
detection contact
51-52 (NC)
61-62 (NC)
63-64 (NO)
Lock monitor
contact
Lock monitor
contact
Even when the door
is closed, it does
not lock until power
is supplied to the
solenoid.
Door closed.
The door is locked.
Door closed.
The door can be
opened.
Notes: 1. The door open/closed detection and lock monitor contact configuration depends on the model.
2. If a current is detected in the solenoid lock model (built-in switches; N,P,Q,R), before the door is closed, the
door will remain unlocked. Be sure to supply power to the solenoid after the door is closed.
The shaded areas indicate the
contact is closed and power is
supplied to the solenoid.
Door open/closed detection
and lock monitor contacts:
Can be used in safety
circuits because of the direct
opening mechanisms.
Door open/closed detection
contact:
Can be used to confirm
whether the key is inserted
and to monitor the open/
closed status of a door.
Lock monitor contact:
Can be used to confirm
whether power is supplied to
the solenoid and to monitor
whether or not a door can be
opened or closed.
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
G67
Datasheet pdf - http://www.DataSheet4U.net/



No Preview Available !

G
G68
Connections
Internal Circuit Diagram
24 VDC D
E1(+)
E2(-)
R
ZD
Control
circuit
LED
D
Circuit Connection Example
• Direct opening contacts used as safety-circuit input are indicated with
the mark.
• Do not switch circuits for three or more standard loads at the same time.
Doing so may adversely affect insulation performance.
• DC solenoids have polarity. (E1: Positive, E2: Negative)
Confirm terminal polarity before wiring.
Connection Example for D4SL-JDG
Terminals 12-41 are connected internally and so connect terminals 11-42
for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
6
8
LED
42
52
64
Lock monitor
switch
41 12
63 34
74
Door open/
closed detection
switch
11 1
51 5
33 3
To safety circuit
To control circuit
To control circuit
To control circuit
Connection Example for D4SL-KDG
Terminals 12-41 are connected internally and so connect terminals 11-42
for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
6
8
LED
42
52
61
Lock monitor
switch
41 12
62 34
74
Door open/
closed detection
switch
11 1
51 5
33 3
To safety circuit
To control circuit
To control circuit
To control circuit
Connection Example for D4SL-LDG
Terminals 12-41 are connected internally and so connect terminals 11-42
for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
6
8
LED
42
52
64
Lock monitor
switch
41 12
63 32
74
Door open/
closed detection
switch
11 1
51 5
31 3
To safety circuit
To control circuit
To control circuit
To control circuit
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
D4SL Safety Interlock Switches
Connection Example for D4SL-MDG
Terminals 12-41 are connected internally and so connect terminals 11-42
for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
6
8
LED
42
52
61
Lock monitor
switch
41 12
62 32
74
Door open/
closed detection
switch
11 1
51 5
31 3
To safety circuit
To control circuit
To control circuit
To control circuit
Connection Example for D4SL-NDA and D4SL-NDG
Terminals 12- 41, and 22- 51 are connected internally and so connect
terminals 11-42, and 21-52 for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
4
8
LED
42
52
64
Lock monitor
switch
Door open/closed
detection switch
41 12
51 22
63 34
11 1
21 3
33 5
76
To safety circuit
To safety circuit
To control circuit
To control circuit
Connection Example for D4SL-PDA and D4SL-PDG
Terminals 12-41, and 22-51 are connected internally and so connect
terminals 11-42, and 21-52 for safety-circuit input. (BIA GS-ET-19)
www.DataSheet.co.kr
9
E1
(+)
10
E2
(-)
2
4
8
LED
42
52
62
Lock monitor
switch
Door open/closed
detection switch
41 12
51 22
61 34
11 1
21 3
33 5
76
To safety circuit
To safety circuit
To control circuit
To control circuit
Connection Example for D4SL-QDA and D4SL-QDG
Terminals 12-41, and 22-51 are connected internally and so connect
terminals 11-42, and 21-52 for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
4
8
LED
42
52
64
Lock monitor
switch
Door open/closed
detection switch
41 12
51 22
63 32
11 1
21 3
31 5
76
To safety circuit
To safety circuit
To control circuit
To control circuit
Connection Example for D4SL-RDA and D4SL-RDG
Terminals 12-41, and 22-51 are connected internally and so connect
terminals 11-42, and 21-52 for safety-circuit input. (BIA GS-ET-19)
9
E1
(+)
10
E2
(-)
2
4
8
LED
42
52
62
Lock monitor
switch
Door open/closed
detection switch
41 12
51 22
61 32
11 1
21 3
31 5
76
For the Latest Information
On the Internet: www.sti.com
To safety circuit
To safety circuit
To control circuit
To control circuit
Datasheet pdf - http://www.DataSheet4U.net/




D4Sl datasheet pdf
Download PDF
D4Sl pdf
View PDF for Mobile


Similiar Datasheets : D40 D40-10 D40-11 D40-11B D40-12 D40-13 D40-20 D40-21 D40-21B D40-22 D40-23 D40-30 D40-31 D40-31B D40-32 D40-33 D40-40 D40-41 D40-41B D40-42 D40-43 D40-50 D40-51 D40-51B D40-52 D40-53 D400 D4001BC D4014 D4015L

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact