ATS48D75Y Datasheet PDF - Schneider

www.Datasheet-PDF.com

ATS48D75Y
Schneider

Part Number ATS48D75Y
Description soft starter for asynchronous motor
Page 2 Pages


ATS48D75Y datasheet pdf
Download PDF
ATS48D75Y pdf
View PDF for Mobile


No Preview Available !

Product data sheet
Characteristics
Complementary
Assembly style
Function available
Power supply voltage limits
Power supply frequency
Power supply frequency limits
Factory setting current
Control circuit voltage
Control circuit consumption
Discrete output number
Discrete output type
Output absolute accuracy precision
Minimum switching current
27-mag-2014
ATS48D75Y
soft starter for asynchronous motor - ATS48 -
65 A - 208..690 V - 15..55 KW
Main
Range of product
Product or component
type
Product destination
Product specific appli-
cation
Component name
Power supply voltage
Motor power kW
Motor power hp
Power dissipation in W
Utilisation category
Type of start
Icl nominal current
IP degree of protection
Altistart 48
Soft starter
Asynchronous motors
Pumping and ventilation machine
Severe and standard applications
ATS48
208...690 V (- 15...10 %)
18.5 kW at 230 V for standard applications
55 kW at 690 V for standard applications
55 kW at 660 V for standard applications
45 kW at 690 V for severe applications
45 kW at 660 V for severe applications
45 kW at 525 V for standard applications
45 kW at 500 V for standard applications
37 kW at 525 V for severe applications
37 kW at 500 V for severe applications
37 kW at 440 V for standard applications
37 kW at 400 V for standard applications
30 kW at 440 V for severe applications
30 kW at 400 V for severe applications
15 kW at 230 V for severe applications
60 hp at 575 V for standard applications
50 hp at 575 V for severe applications
50 hp at 460 V for standard applications
40 hp at 460 V for severe applications
25 hp at 230 V for standard applications
20 hp at 230 V for severe applications
20 hp at 208 V for standard applications
15 hp at 208 V for severe applications
245 W for standard applications
201 W for standard applications
AC-53A
Start with torque control (current limited to 5 In)
75 A for standard applications
62 A for standard applications
IP20
With heat sink
External bypass (optional)
177...759 V
50...60 Hz (- 5...5 %)
47.5...63 Hz
65 A
110 - 15 % to 230 + 10 %, 50/60 Hz
30 W
2
(R3) relay outputs motor powered NO
(R2) relay outputs end of starting relay NO
(R1) relay outputs fault relay NO
(LO2) logic output 0 V common configurable
(LO1) logic output 0 V common configurable
+/- 5 %
Relay outputs 10 mA at 6 V DC
1



No Preview Available !

Maximum switching current
Discrete input number
Discrete input type
Discrete input voltage
Discrete input logic
Starting current
Analogue output type
Communication port protocol
Connector type
Communication data link
Physical interface
Transmission rate
Max nodes number
Protection type
Marking
Type of cooling
Operating position
Height
Width
Depth
Product weight
Environment
Electromagnetic compatibility
Standards
Product certifications
Vibration resistance
Shock resistance
Noise level
Pollution degree
Relative humidity
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
Contractual warranty
Period
2
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms
Logic output 0.2 A at 30 V DC
5
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
24 V (<= 30 V)
(Stop, Run, LI3, LI4) positive logic state 0 < 5 V and < 2 mA, state 1 > 11 V and >
5 mA
Adjustable 0.4...1.3 Icl
(AO) current output 0-20 mA or 4-20 mA <= 500 Ohm
Modbus
1 RJ45
Serial
RS485 multidrop
4800, 9600 or 19200 bps
31
Thermal protection (starter)
Thermal protection (motor)
Phase failure (line)
CE
Forced convection
Vertical +/- 10 degree
290 mm
190 mm
235 mm
8.3 kg
Voltage/Current impulse conforming to IEC 61000-4-5 level 3
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 le-
vel 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Electrostatic discharge conforming to IEC 61000-4-2 level 3
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Conducted and radiated emissions conforming to IEC 60947-4-2 level B
Conducted and radiated emissions conforming to IEC 60947-4-2 level A
EN/IEC 60947-4-2
CCC
CSA
C-Tick
DNV
GOST
NOM 117
SEPRO
TCF
UL
1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
15 gn for 11 ms conforming to EN/IEC 60068-2-27
58 dB
Level 3 conforming to IEC 60664-1
<= 95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
-10...40 °C without derating
> 40...60 °C with current derating of 2 % per °C
-25...70 °C
> 1000...2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
18 months



ATS48D75Y datasheet pdf
Download PDF
ATS48D75Y pdf
View PDF for Mobile


Related : Start with ATS48D75 Part Numbers by
ATS48D75Y soft starter for asynchronous motor ATS48D75Y
Schneider
ATS48D75Y pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact