Characteristics
Complementary
Assembly style
Function available
Power supply voltage limits
Power supply frequency
Network frequency
Device connection
Control circuit voltage
Control circuit consumption
Discrete output number
Discrete output type
Minimum switching current
Maximum switching current
Discrete input number
Discrete input type
Discrete input voltage
Discrete input logic
Output current
PTC probe input
Communication port protocol
Connector type
Communication data link
Physical interface
Mar 9, 2013
ATS22D75Q
soft starter-ATS22-control 220V-power
230V(18.5kW)/400...440V(37kW)
Main
Range of product
Product or component
type
Product destination
Product specific appli-
cation
Component name
Network number of
phases
Power supply voltage
Motor power kW
Factory setting current
Power dissipation in W
Utilisation category
Type of start
Icl nominal current
IP degree of protection
Altistart 22
Soft starter
Asynchronous motors
Severe and standard applications
ATS22
3 phases
230...440 V (- 15...10 %)
18.5 kW at 230 V
37 kW at 440 V
37 kW at 400 V
69 A
63 W for standard applications
AC-53A
Start with torque control (current limited to 3.5 In)
75 A (connection in the motor supply line) for stan-
dard applications
IP20
With heat sink
Internal bypass
195...484 V
50...60 Hz (- 10...10 %)
45...66 Hz
In the motor supply line
To the motor delta terminals
220...230 V -15...10 % at 50/60 Hz
20 W
2
(R2)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
(R1)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
Relay outputs 100 mA at 12 V, DC
Relay outputs 2 A at 30 V, DC inductive load, L/R = 7 ms
Relay outputs 2 A at 250 V, AC inductive load, cos phi = 0.4, L/R = 20 ms
Relay outputs 5 A at 30 V, DC resistive load, cos phi = 1
Relay outputs 5 A at 250 V, AC resistive load, cos phi = 1
3
(LI1, LI2, LI3)logic 5 mA 4.3 kOhm
24 V (<= 30 V)
(LI1, LI2, LI3)positive logic state 0 < 5 V and < 2 mA state 1 > 11 V and > 5 mA
0.4...1 Icl adjustable
750 Ohm
Modbus
1 RJ45
Serial
RS485 multidrop
1



No Preview Available !

Transmission rate
Max nodes number
Protection type
Marking
Type of cooling
Operating position
Height
Width
Depth
Product weight
Environment
Electromagnetic compatibility
Standards
Product certifications
Vibration resistance
Shock resistance
Noise level
Pollution degree
Relative humidity
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
Offer Sustainability
Sustainable offer status
RoHS
Product environmental profile
Product end of life instruction
4800, 9600 or 19200 bps
31
Thermal protection on starter
Thermal protection on motor
Phase failure on line
CE
Forced convection
Vertical +/- 10 degree
295 mm
145 mm
207 mm
12 kg
Voltage/Current impulse conforming to IEC 61000-4-5 level 3
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3
level 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Electrostatic discharge conforming to IEC 61000-4-2 level 3
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Conducted and radiated emissions conforming to IEC 60947-4-2 level A
EN/IEC 60947-4-2
CCC
CSA
C-Tick
GOST
UL
1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
15 gn for 11 ms conforming to EN/IEC 60068-2-27
45 dB
Level 2 conforming to IEC 60664-1
<= 95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
> 40...< 60 °C with current derating 2.2 % per °C
-10...40 °C without derating
-25...70 °C
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
Not Green Premium product
Compliant - since 0938 - Schneider Electric declaration of conformity
declaration of conformity
Available Download Product Environmental
Available Download End Of Life Manual
download
2



No Preview Available !

Product data sheet
Dimensions Drawings
ATS22D75Q
Frame Size B
Dimensions
3



No Preview Available !

Product data sheet
Mounting and Clearance
ATS22D75Q
Precautions
Standards
The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1.
For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
ATS22 soft starters are open devices and must be mounted in a suitable enclosure.
Failure to follow these instructions will result in death or serious injury.
Air Circulation
Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit.
Overheating
To avoid the soft starter to overheat, respect the following recommendations:
● Mount the Altistart 22 Soft Starter within ± 10° of vertical.
● Do not locate the Altistart 22 Soft Starter near heat radiating elements.
● Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air immediately
surrounding the soft starter. To help prevent a thermal fault, provide sufficient enclosure cooling and/or ventilation to limit the ambient
temperature around the soft starter.
● If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat generated from the
bottom soft starter can adversely affect the ambient temperature around the top soft starter.
Mounting
4



ATS22D75Q datasheet pdf
Download PDF
ATS22D75Q pdf
View PDF for Mobile


Related : Start with ATS22D75 Part Numbers by
ATS22D75Q soft starter ATS22D75Q
Schneider
ATS22D75Q pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact