Characteristics
Complementary
Assembly style
Function available
Power supply voltage limits
Power supply frequency
Network frequency
Device connection
Control circuit voltage
Control circuit consumption
Discrete output number
Discrete output type
Minimum switching current
Maximum switching current
Discrete input number
Discrete input type
Discrete input voltage
Discrete input logic
Output current
PTC probe input
Communication port protocol
Connector type
Communication data link
Physical interface
Mar 9, 2013
ATS22D75Q
soft starter-ATS22-control 220V-power
230V(18.5kW)/400...440V(37kW)
Main
Range of product
Product or component
type
Product destination
Product specific appli-
cation
Component name
Network number of
phases
Power supply voltage
Motor power kW
Factory setting current
Power dissipation in W
Utilisation category
Type of start
Icl nominal current
IP degree of protection
Altistart 22
Soft starter
Asynchronous motors
Severe and standard applications
ATS22
3 phases
230...440 V (- 15...10 %)
18.5 kW at 230 V
37 kW at 440 V
37 kW at 400 V
69 A
63 W for standard applications
AC-53A
Start with torque control (current limited to 3.5 In)
75 A (connection in the motor supply line) for stan-
dard applications
IP20
With heat sink
Internal bypass
195...484 V
50...60 Hz (- 10...10 %)
45...66 Hz
In the motor supply line
To the motor delta terminals
220...230 V -15...10 % at 50/60 Hz
20 W
2
(R2)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
(R1)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
Relay outputs 100 mA at 12 V, DC
Relay outputs 2 A at 30 V, DC inductive load, L/R = 7 ms
Relay outputs 2 A at 250 V, AC inductive load, cos phi = 0.4, L/R = 20 ms
Relay outputs 5 A at 30 V, DC resistive load, cos phi = 1
Relay outputs 5 A at 250 V, AC resistive load, cos phi = 1
3
(LI1, LI2, LI3)logic 5 mA 4.3 kOhm
24 V (<= 30 V)
(LI1, LI2, LI3)positive logic state 0 < 5 V and < 2 mA state 1 > 11 V and > 5 mA
0.4...1 Icl adjustable
750 Ohm
Modbus
1 RJ45
Serial
RS485 multidrop