AMEL5-AZ Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AMEL5-AZ
AIMTEC

Part Number AMEL5-AZ
Description AC-DC / DC-DC Converter
Page 5 Pages


AMEL5-AZ datasheet pdf
Download PDF for PC
AMEL5-AZ pdf
View PDF for Mobile


No Preview Available !

Click on Series name for product info on aimtec.com
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:
I/O Isolation 3000VAC
Operating Temp: -40 oC to +95 oC
Input: 90-305VAC, 47-440Hz, or 130-430VDC
Over load, Over Voltage, Short Circuit Protection
RoHS compliant
Energy Star compliant
Efficiency up to 76%
Soft start
Models
Single output
Model
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current
max (A)
Maximum
capacitive
Load
(µF)
Efficiency
(%)
115
VAC
230
VAC
277
VAC
AMEL5-3.3SAZ
90-305/47-440 130-430
-40 to +95
3.3
1. 5
2200
71 71 69
AMEL5-5SAZ
90-305/47-440 130-430
-40 to +95
5
1
1100
72 73 72
AMEL5-12SAZ
90-305/47-440 130-430
-40 to +95
12
0.42 680 75 76 76
AMEL5-15SAZ
90-305/47-440 130-430
-40 to +95
15
0.333
330 75 75 73
AMEL5-24SAZ
90-305/47-440 130-430
-40 to +95
24
0.21 220 75 76 75
Note: 1. Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SAZ-ST);
2. Optional version with incorporated filter for Earth to Ground connection can be ordered by adding “Gto the model suffix (ex.
AMEL5-5SGAZ).
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(110/230/277 VAC)
115 VAC/ Full Load
Typical
1.5
0.2
150
Maximum
120
80
70
15
30
40
0.2
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Conditions
Typical
Maximum
Voltage accuracy
±2
Line regulation
±1
Load regulation
0-100% load
±1
Transient recovery time
200
Transient response deviation
25% load step
±2
3.3/5V models
75
Ripple & Noise*
12/15V models
100
24V models
150
Hold-up time
5
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Units
%
%
%
µs
% of Vout
mV p-p
mV p-p
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Rated
3000
Units
VAC
www.aimtec.com
F 052e R8.Q
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only

AMEL5-AZ datasheet pdf
Download PDF for PC
AMEL5-AZ pdf
View PDF for Mobile


Related : Start with AMEL5-A Part Numbers by
AMEL5-AZ AC-DC / DC-DC Converter AMEL5-AZ
AIMTEC
AMEL5-AZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   NEW   

Since 2010   ::   HOME   ::   Contact