AMEL20-AZ Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AMEL20-AZ
AIMTEC

Part Number AMEL20-AZ
Description AC-DC / DC-DC Converter
Page 5 Pages


AMEL20-AZ datasheet pdf
Download PDF
AMEL20-AZ pdf
View PDF for Mobile

No Preview Available !

FEATURES:
Click on Series name for product info on aimtec.com
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
I/O Isolation 3000VAC
Operating Temp: -40 oC to +80 oC
Over load and, Over Voltage Protection
Input: 90-305VAC, 47-440Hz, or 130-430VDC
Energy Star compliant
Ultra small package
Up to 81% efficiency
Short Circuit Protection
Models
Single output
CB 
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Voltage(V)
Output
Current
max (A)
Maximum
capacitive
load (µF)
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMEL20-3.3SAZ 90-305/47-440 130-430
13.2
3.3
4
5600
73 73 72
AMEL20-5SAZ
90-305/47-440 130-430
20
5
4
4700
77 77 76
AMEL20-12SAZ
90-305/47-440 130-430
20
12
1.66
3300
80 80 80
AMEL20-15SAZ
90-305/47-440 130-430
20
15
1.33
2200
81 80 80
AMEL20-24SAZ
90-305/47-440 130-430
20
24
0.84
1000
79 80 79
Note: Optional mounting plate version can be order by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(115/230/277 VAC)
Typical
1.5
0.5
150
Maximum
460
290
260
30
50
55
0.25
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time
Conditions
(LL-HL)
0-100% load
25% load step
Typical
±2
±1
±2
500
±2
200
10
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor.
Maximum
Units
%
%
%
µs
% of Vout
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
60 sec
Typical
>1000
Rated
3000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Conditions
Foldback
Typical
65
130
Zener Diode Clamp
Maximum
Units
KHz
%
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Short circuit protection
Auto recovery
Operating temperature
With derating over 50ºC
Refer to Chart
oC
Maximum case temperature
100 oC
Storage temperature
-45 to +95
oC
Temperature coefficient
±0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
70 g
Dimensions (L x W x H)
56.48 x 30.86 x 25.10mm (2.22 x 1.21 x 0.99 inches)
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage
(115/230/277VAC) and at rated output load unless otherwise specified.
Environment Approval
Test
Parameters
Wave form
Shock
Acceleration amplitude
Bump duration
Converter operation
Vibration
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
CE, UL, FCC, CB
Information Technology Equipment
Information Technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
FCC
UL 60950-1: 2nd Edition
CAN/CSA-C22.2 No.60950-1-07, 2nd Edition
EN55022, class B
EN55024: 2010
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, :2008
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006 + A1: 2007 + A2:2010
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
IEC 61000-4-11: 2004
47 CFR Part 15 Subpart B, ICES-003 Iss. 5-2012,
ANSI C63.4-2009
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Additional Surge Protective Circuitry
The AMEL20-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
S14K320E2
Vrms
V
320
Pin Out Specifications
Pin Single
1 AC Input (N)
2 AC Input (L)
3 +V Output
4 -V Output
5 No pin
Derating
Vdc
Wmax (2ms)
Pmax
V JW
420 136 0.6
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Dimensions
1
56.46
(2.22)
45.72
(1.80)
Top View
3
4
25
5.37
(0.21)
Temperature Measurement
point
5.37
(0.21)
1.05
(0.04)
13
4
25
DIV: 10.00 (0.40)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AMEL20-AZ datasheet pdf
Download PDF
AMEL20-AZ pdf
View PDF for Mobile


Related : Start with AMEL20-A Part Numbers by
AMEL20-AZ AC-DC / DC-DC Converter AMEL20-AZ
AIMTEC
AMEL20-AZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact