AMEL10-AZ Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AMEL10-AZ
AIMTEC

Part Number AMEL10-AZ
Description AC-DC / DC-DC Converter
Page 5 Pages


AMEL10-AZ datasheet pdf
Download PDF
AMEL10-AZ pdf
View PDF for Mobile


No Preview Available !

Click on Series name for product info on aimtec.com
Series AMEL10-AZ
10 Watt | AC-DC / DC-DC Converter
FEATURES:
I/O Isolation 3000VAC
RoHS Compliant
Operating Temp: -40 oC to +80 oC
Energy Star Compliant
Input: 90-305VAC, 47-440Hz, or 130-430VDC Efficiency up to 83%
Over Load, Over Voltage, Short Circuit Protection Soft Start
Models
Single output
CB
Model
AMEL10-3.3SAZ
AMEL10-5SAZ
AMEL10-12SAZ
AMEL10-15SAZ
AMEL10-24SAZ
Input
Voltage
(VAC/Hz)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
Input
Voltage
(VDC)
130-430
130-430
130-430
130-430
130-430
Temperature
range
(ºC)
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
Output
Voltage
(V)
3.3
5
12
15
24
Output
Current
max (A)
3.00
2.00
0.84
0.67
0.42
Maximum
capacitive
Load
(µF)
2200
1000
680
470
470
Efficiency
(%)
115 230 277
VAC VAC VAC
75 74 73
77 75 74
83 82 81
83 81 80
82 81 79
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SAZ-ST)
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(110/230/277 VAC)
Typical
1
0.2
50
Maximum
230
150
140
20
35
50
0.25
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
±2
Line regulation
±1
Load regulation
0-100% load
±2
Transient recovery time
500
Transient response deviation
25% load step
±2
3.3/5V models
75
Ripple & Noise*
12/15V models
100
24V models
150
Hold-up time
15
* Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Maximum
Units
%
%
%
µs
% of Vout
mV p-p
mV p-p
mV p-p
ms
Rated
3000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
www.aimtec.com
F 052e R8.K
Conditions
Foldback
Typical
66
130
Zener Diode Clamp
Tel: +1 514 620 2722
1 of 5
Maximum
Units
KHz
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AMEL10-AZ
10 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Short circuit protection
Auto recovery
Operating temperature
With derating over 60ºC
Refer to model application
oC
Storage temperature
-40 to +95
oC
Maximum case temperature
100 oC
Temperature coefficient
±0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
70 g
Dimensions (L x W x H)
56.48 x 30.86 x 25.10mm (2.22 x 1.21 x 0.99inches)
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Parameters
Wave form
Acceleration amplitude
Shock
Bump duration
Converter operation
Number of bumps
Test mode
Vibration
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
EN 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Additional Surge Protective Circuitry
Series AMEL10-AZ
10 Watt | AC-DC / DC-DC Converter
The AMEL10-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
S14K320E2
Vrms
V
320
Pin Out Specifications
Pin Single
1 AC Input (N)
2 AC Input (L)
3 +V Output
4 -V Output
5 No pin
Derating
Vdc
Wmax (2ms)
Pmax
V JW
420 136 0.6
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Dimensions
Series AMEL10-AZ
10 Watt | AC-DC / DC-DC Converter
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AMEL10-AZ datasheet pdf
Download PDF
AMEL10-AZ pdf
View PDF for Mobile


Related : Start with AMEL10-A Part Numbers by
AMEL10-AZ AC-DC / DC-DC Converter AMEL10-AZ
AIMTEC
AMEL10-AZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact