15 Watt | AC-DC / DC-DC Converter
Models
Single output
Model
AMEC15-3.3SMAZ
AMEC15-5SMAZ
AMEC15-12SMAZ
AMEC15-15SMAZ
AMEC15-24SMAZ
Models
Dual output
Model
AMEC15-5DMAZ
AMEC15-12DMAZ
AMEC15-15DMAZ
FEATURES:
Connector on Input & Output
Operating temperature: -40 to +80°C
Over load, Over Voltage, Short Circuit Protection
Optional DIN Rail mounting bracket
Universal input: 90-264VAC, 47-440Hz
RoHS compliant
Soft start
Energy Star compliant
CE, cULus, CB approvals
4000VAC I/O Isolation
CB
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
Input voltage
(VDC)
130-370
130-370
130-370
130-370
130-370
Output
Voltage
(V)
3.3
5
12
15
24
Output
Current
max (A)
3
3
1.25
1
0.63
Maximum
Capacitive Load
(µF)
4700
2200
1000
680
470
Efficiency
(%)
115 230
VAC
VAC
74 74
75 76
81 82
81 83
83 83
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
Input voltage
(VDC)
130-370
130-370
130-370
Output
Voltage
(V)
±5
±12
±15
Output
Current
max (A)
±1.5
±0.63
±0.5
Maximum
Capacitive Load
(µF)
±1000
±470
±330
Efficiency
(%)
115 230
VAC
VAC
78 79
81 82
82 83
Input Specifications
Parameters
Current (Full Load)
Inrush current <2ms
Leakage current
External Fuse
Input Dissipation
Under Voltage Protection
Conditions
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
recommend slow blow type
115 / 230 VAC
Typical
2
0.2
85
Maximum
350
180
20
30
0.1
0.2
Units
mA
mA
A
A
mA
mA
A
W
VAC
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
±2
Line regulation
LL-HL
±1
Load regulation (single output)
0-100%
±1
Cross regulation (dual output)
25% load - 1st out, 100% load – 2nd out
±5
Transient Recovery Time
200
Transient Recovery Deviation
25% load step
±2
3.3/5V models
75
Ripple & Noise*
12/15V models
100
24V models
150
Hold-up time
min 20
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47μF (E/C) parallel capacitor.
Maximum
Units
%
%
%
%
µs
% of Vout
mVp-p
ms
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
60 sec
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
Typical
>1000
Rated
4000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Protection Class
Start up time
Over load protection
Over voltage protection
Short Circuit protection
Case Material
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
Maximum
132
Class II
350
Foldback
130
Zener diode clamp
Auto recovery
Metal
With derating over 55 oC (10CFM)
-40 to +80
-50 to +100
100
±0.02
Free air convection
95
100
3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm
> 400 000hrs (MIL-HDBK -217F, t=+25oC)
Units
KHz
mS
%
oC
oC
oC
% / oC
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Wave form: Half sine wave
Conditions
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals cULus, CE, CB
Standards
Medical Electrical Equipment
Information technology Equipment
Harmonic Current Emissions
EMI - Conducted and radiated emission
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
IEC/EN 61000-3-2, Class A
EN55011, class B
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Derating
A
100
B
80
60
40 Safe Operating Area
20
0
- 40 - 20 0
20 40 60 8085 100
Ambient Temperature º C
A
Free Air
Convection
40 º C
B
10 CFM
55 º C
Pin Out Specifications
Pin Single
1 AC Input (N)
2 AC Input (L)
3 -V Output
4 No Connection
5 +V Output
Dual
AC Input (N)
AC Input (L)
-V Output
Common
+V Output
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Dimensions
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
PCB Mounting
Screw
PCB
PCB Mounting
Screw
Mylar Film
Bracket
Mountin
g Screw
PCB
Mylar Film
2.6 mm Max
Side View
Customer Chassis
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AMEC15-MAZ datasheet pdf
Download PDF
AMEC15-MAZ pdf
View PDF for Mobile


Related : Start with AMEC15-MA Part Numbers by
AMEC15-MAZ AC-DC / DC-DC Converter AMEC15-MAZ
AIMTEC
AMEC15-MAZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact