AME30-MAZ Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AME30-MAZ
AIMTEC

Part Number AME30-MAZ
Description AC-DC / DC-DC Converter
Page 4 Pages


AME30-MAZ datasheet pdf
Download PDF
AME30-MAZ pdf
View PDF for Mobile


No Preview Available !

Click on Series name for product info on aimtec.com
Series AME30-MAZ
30 Watt | AC-DC / DC-DC Converter
FEATURES:
Models
Single output
Model
AME30-3.3SMAZ
AME30-5SMAZ
AME30-12SMAZ
AME30-15SMAZ
AME30-24SMAZ
4000VAC I/O isolation
Medical Switching power modules for PCB mounting
Operating temperature: -40 to +85°C
Universal Input: 90-264VAC, 47-440Hz, or 130-370VDC
Energy star compliant
RoHS compliant
Low Ripple and Noise
CE, cULus, BC approvals
CB
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
Input Voltage
(VDC)
130-370
130-370
130-370
130-370
130-370
Output
Voltage
(V)
3.3
5
12
15
24
Maximum
Capacitive
load (µF)
8200
8200
2200
1500
560
Output Current
max
(A)
6
6
2.5
2
1.25
Efficiency
(%)
115 230
VAC
VAC
79 77
82 81
84 82
84 82
83 82
Models
Dual output
Model
Input Voltage Input Voltage
(VAC/Hz)
(VDC)
Output
Voltage
(V)
Maximum
Capacitive
load (µF)
Output Current
max
(A)
Efficiency
(%)
115 230
VAC
VAC
AME30-5DMAZ
90-264/47-440
130-370
±5
3300
±3 80 80
AME30-12DMAZ 90-264/47-440
130-370
±12
2200
±1.25
82 82
AME30-15DMAZ 90-264/47-440
130-370
±15
1000
±1 82 81
AME30-24DMAZ 90-260/47-440
130-370
±24
470
±0.625
77 76
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Recommended slow blow type
115 / 230 VAC
Typical
3.15
0.5
250
Maximum
740
410
25
50
150
Units
mA
mA
A
A
µA
A
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Cross regulation
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Minimum Load Current
Conditions
(LL-HL)
0-100% load single
0-100% load dual
25% load - 1st out, 100% load – 2nd out
25% load Step
3.3 / 5V models
12 / 15V models
24V models
*Ripple & Noise measured at 20MHz bandwidth by using with 0.1μF M/C and47μF E/C
Typical
±2
±1
±1
±2
±5
±2
75
100
150
25
0
Maximum
Units
%
%
%
%
% of Vout
mV p-p
ms
% of Max
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Series AME30-MAZ
30 Watt | AC-DC / DC-DC Converter
Typical
>1000
Rated
4000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short Circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L X H X W)
MTBF
Conditions
Typical
Maximum
47
Class II
Fold back
130
Zener diode clamp
110
Auto recovery
Auto recovery
With derating above 55ºC
-40 - +85 (see model table)
100
-40 to +95
0.02
Free air convection
Non condensing
95
Plastic (flammability to UL 94V-0)
300
3.56 x 2.48 x 1.18 inches 90.5 x 63 x 30 mm
> 800,000 hrs (MIL-HDBK -217F, t=+25 oC)/Full Load
> 200,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
Units
KHz
%
%
oC
oC
oC
% / oC
% RH
g
Environment Approval
Test
Shock
Parameters
Wave form
Acceleration amplitude
Bump duration
Vibration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Standards
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-
M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 2
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Pin Out Specifications
Pin Single
Dual
1 AC Input (N) AC Input (N)
2 AC Input (L) AC Input (L)
3 +V Output +V Output
4 -V Output
Common
5 N. C. -V Output
Dimensions
Series AME30-MAZ
30 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection
55ºC
100
80
60 Safe Operating Area
40
20
0
- 40 - 20
0
20 40 60 8085 100
Ambient Temperature º C
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AME30-MAZ
30 Watt | AC-DC / DC-DC Converter
Earth/Ground Connection EMC EN55022 class B compliant Application circuit
L1
35mH
ASE2501VG
L +Vout
90-264VAC
      CX1
        0.6uF
N
      CX2
        0.6uF
AMExw30MAZ
-Vout
        
                
The Application circuit is EMC compliant for any type of Earth/Ground connection: Input Ground connection, Output Ground connection as
shown or both sides, which is not recommended if the product Isolation is used as a Safety feature.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.K
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AME30-MAZ datasheet pdf
Download PDF
AME30-MAZ pdf
View PDF for Mobile


Related : Start with AME30-MA Part Numbers by
AME30-MAZ AC-DC / DC-DC Converter AME30-MAZ
AIMTEC
AME30-MAZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact