AME2-AZ Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AME2-AZ
AIMTEC

Part Number AME2-AZ
Description AC-DC Converter
Page 3 Pages


AME2-AZ datasheet pdf
Download PDF
AME2-AZ pdf
View PDF for Mobile

No Preview Available !

Click on Series name for product info on aimtec.com
FEATURES:
Series AME2-AZ
2Watt | AC-DC Converter
Models
Single output
Model
AME2-3.3SAZ
AME2-5SAZ
AME2-12SAZ
AME2-15SAZ
AME2-24SAZ
AME2-3.3SBAZ
AME2-5SBAZ
AME2-12SBAZ
AME2-15SBAZ
AME2-24SBAZ
I/O Isolation 3000VAC
Operating Temp: -40°C to +70°C
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Over load, Short Circuit Protection
RoHS compliant
Energy Star compliant
Ultra small package
Input
Voltage
(VAC/Hz)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
Input
Voltage
(VDC)
130-430
130-430
130-430
130-430
130-430
130-745
130-745
130-745
130-745
130-745
Temperature
range
(ºC)
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
-40 to +70
Output
Voltage
(V)
3.3
5
12
15
24
3.3
5
12
15
24
Output
Current max
(mA)
600
400
166
133
83
Maximum
capacitive
Load
(µF)
2200
1100
680
560
470
Efficiency
(%)
115 230 277 480
VAC VAC VAC VAC
64 63 61
67 66 63
75 72 69
78 74 71
81 81 79
600
2200
57 57 56 50
400
1100
63 63 62 56
166 680 68 68 66 53
133 560 68 67 66 57
83 470 67 67 65 58
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Recommended slow blow type
Typical
1
0.3
Maximum
40
20
20
15
10
15
20
30
0.15
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Full load (typical)*
±5
Line regulation
LL-HL, Full Load
±1.5
Load regulation (single output)
0-100% load (typical)*
±5
Transient Recovery Time
200
Transient Response Deviation
25% load step
±2
Minimum load
0
3.3/5 VAC With 560µF E/C
200
Ripple & Noise
12/15 VAC With 220µF E/C
400
24 VAC With 220µF E/C
500
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Maximum
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Rated
3000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
Operating temperature
www.aimtec.com
F 052e R8.H
Conditions
Typical
100
Auto recovery
>125%
Auto recovery
Without derating
Tel: +1 514 620 2722
-40 to +70
1 of 3
Maximum
Units
KHz
oC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AME2-AZ
2Watt | AC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Storage temperature
-40 to +85
oC
Maximum Case temperature
100 oC
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
25 g
Dimensions (L x W x H)
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB, FCC
Information technology Equipment
IEC/EN/UL 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55022, class B (* see note)
Standards
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ: Level 2,SBAZ: Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close
as possible to the input of the power supply itself
Pin Out Specifications*
Pin
1*
2*
3
4
Single
AC Input (N) or (L1)
AC Input (L) or (L2)
-V Output
+V Output
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase,
240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Derating
Series AME2-AZ
2Watt | AC-DC Converter
Dimensions
35.60
(1.40)
15.24
(0.60)
1
Top View
3
4
7.60
(0.29)
23.31
(0.92)
(0.65)
Top View
1 Te mperat urem easuringpoint 3
4
11.655
(0.46)
2
28.00
(1.10)
19.32
(0.76)
Side View
  
 
6.00
(0.24)
2
DIV: 5.00(0.20)
Ø 10.0 ( Ø 0.40)
Ø 0.60 ( Ø 0.02)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter ±0.05 (±0.002)
Pin Pitch Tolerance ±0.50 (±0.02)
0.60
(0.02)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AME2-AZ datasheet pdf
Download PDF
AME2-AZ pdf
View PDF for Mobile


Related : Start with AME2-A Part Numbers by
AME2-AZ AC-DC Converter AME2-AZ
AIMTEC
AME2-AZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact