FEATURES:
Under Voltage Lockout
High efficiency up to 84%
24 Pin DIP Package
Wide 4:1 input range
Over Load Protection
Series AM6TIW-RZ
6 Watt | DC-DC Converter
Operating temperature -40oC to + 85oC
Continuous short circuit protection
Input / Output Isolation 1500 and 3000VDC
Pin compatible with multiple manufacturers
Input Under Voltage Protection
Models
Single output
Model
AM6TIW-2403S-RZ
AM6TIW-2405S-RZ
AM6TIW-2412S-RZ
AM6TIW-2415S-RZ
AM6TIW-2424S-RZ
AM6TIW-4803S-RZ
AM6TIW-4805S-RZ
AM6TIW-4812S-RZ
AM6TIW-4815S-RZ
AM6TIW-4824S-RZ
AM6TIW-2403SH30-RZ
AM6TIW-2405SH30-RZ
AM6TIW-2412SH30-RZ
AM6TIW-2415SH30-RZ
AM6TIW-2424SH30-RZ
AM6TIW-4803SH30-RZ
AM6TIW-4805SH30-RZ
AM6TIW-4812SH30-RZ
AM6TIW-4815SH30-RZ
AM6TIW-4824SH30-RZ
Input
Voltage
(V)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
Output
Output Current
Voltage (V)
max (mA)
3.3 1400
5 1200
12 500
15 400
24 250
3.3 1400
5 1200
12 500
15 400
24 250
3.3 1400
5 1200
12 500
15 400
24 250
3.3 1400
5 1200
12 500
15 400
24 250
Efficiency
(%)
78
80
84
84
84
76
82
84
84
84
78
80
84
84
84
76
82
84
84
84
Capacitive
load, max (μF)
470
470
100
100
47
470
470
100
100
47
470
470
100
100
47
470
470
100
100
47
Models
Dual output
Model
AM6TIW-2403D-RZ
AM6TIW-2405D-RZ
AM6TIW-2412D-RZ
AM6TIW-2415D-RZ
AM6TIW-2424D-RZ
AM6TIW-4803D-RZ
AM6TIW-4805D-RZ
AM6TIW-4812D-RZ
AM6TIW-4815D-RZ
AM6TIW-4824D-RZ
AM6TIW-2403DH30-RZ
AM6TIW-2405DH30-RZ
AM6TIW-2412DH30-RZ
AM6TIW-2415DH30-RZ
AM6TIW-2424DH30-RZ
AM6TIW-4803DH30-RZ
Input
Voltage
(V)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
9-36
9-36
9-36
9-36
9-36
18-75
Output
Voltage (V)
±3.3
±5
±12
±15
±24
±3.3
±5
±12
±15
±24
±3.3
±5
±12
±15
±24
±3.3
Output Current
max (mA)
±909
±600
±250
±200
±125
±909
±600
±250
±200
±125
±909
±600
±250
±200
±125
±909
Efficiency
(%)
78
82
84
84
82
78
82
84
84
80
78
82
84
84
82
78
Capacitive
load, max (μF)
±220
±220
±100
±100
±47
±220
±220
±100
±100
±47
±220
±220
±100
±100
±47
±220
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Models
Dual output (continued)
Input
Model
Voltage
(V)
AM6TIW-4805DH30-RZ
18-75
AM6TIW-4812DH30-RZ
18-75
AM6TIW-4815DH30-RZ
18-75
AM6TIW-4824DH30-RZ
18-75
Output
Voltage (V)
±5
±12
±15
±24
Output Current
max (mA)
±600
±250
±200
±125
Series AM6TIW-RZ
6 Watt | DC-DC Converter
Efficiency
(%)
82
84
84
80
Capacitive
load, max (μF)
±220
±100
±100
±47
Isolation
(VDC)
3000
3000
3000
3000
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Under Voltage Lockout (ON / OFF)
Input Reflected Ripple Current
Nominal
24
48
24 Vin
48 Vin
24 Vin
48 Vin
Typical
9-36
18-75
20
-0.7-50
-0.7-100
100
8.5 / 7.0
16.5 / 14.5
20
Maximum
π (Pi) Network
Units
VDC
ms
VDC
ms
VDC
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3 sec
Typical
> 1000
1000
Rated
1500 or 3000
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Short Circuit protection
Short circuit restart
Over current protection
Line voltage regulation
Cross regulation (Dual)
Load voltage regulation
Temperature coefficient
Ripple & Noise
Rising time
Transient Recovery Time
Transient Response Deviation
Conditions
Vin nom, 100% load
Balanced Load
LL – HL, 100% load
1 load=25-100%, other
load=100%
0 – 100% load
At 20MHz Bandwidth
Vin nom, 25% step
Typical
Maximum
±2
±2
Continuous
Auto recovery
160% Iout
±0.5
±5
±1.2
±0.02
60
80
300
±3
Units
%
%
%
%
%
%/oC
mV p-p
ms
µs
%
General Specifications
Parameters
Start-up Time
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
www.aimtec.com
F 051e R12.B
Conditions
100% load
(See Derating Chart)
Typical
Maximum
20
330
-40 to +85
-55 to +125
+100
Free air convection
90
Non-Conductive Black Plastic (UL94V-0)
13
Tel: +1 514 620 2722
2 of 4
Units
ms
KHz
oC
oC
oC
%
g
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AM6TIW-RZ
6 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Dimensions(L x W x H) Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.84 x 0.41 inches 31.75 x 21.35 x 10.50 mm
MTBF
>800,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications noted in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal
input voltage and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approval
Standards
CE, UL
IEC/EN 60950-1
EN 55022 Class A
EN 55024 Class A
IEC61000-4-2, Perf. Criteria A
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A
IEC61000-4-5, Perf. Criteria A
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Pin Out Specifications
Pin 1500 & 3500VDC
Single
Dual
2 -V Input
-V Input
3 -V Input
-V Input
9 NO PIN
Common
11 N. C.
-V Output
14 +V Output
+V Output
16 -V Output
Common
22 +V Input
+V Input
23 +V Input
+V Input
Dimensions
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Derating
100
Free Air Convection
60 ºC
Series AM6TIW-RZ
6 Watt | DC-DC Converter
80
60
Safe Operating Area
40
20
0
-40 -25 0 20 40 60 80 85 100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AM6TIW-RZ datasheet pdf
Download PDF
AM6TIW-RZ pdf
View PDF for Mobile


Related : Start with AM6TIW-R Part Numbers by
AM6TIW-RZ DC-DC Converter AM6TIW-RZ
AIMTEC
AM6TIW-RZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact