FEATURES:
RoHS Compliant
Wide 2:1 input range
High Efficiency up to 86%
Continuous short circuit
Click on Series name for product info on aimtec.com
Series AM6Q-Z
6 Watt | DC-DC Converter
Operating Temperature -40ºC to 85ºC
Input / Output Isolation of 500VAC
No Tantalum capacitors used inside
Over voltage protection
Models
Single output
Model
AM6Q-0503SZ
AM6Q-0505SZ
AM6Q-0512SZ
AM6Q-0515SZ
AM6Q-1203SZ
AM6Q-1205SZ
AM6Q-1212SZ
AM6Q-1215SZ
AM6Q-2403SZ
AM6Q-2405SZ
AM6Q-2412SZ
AM6Q-2415SZ
AM6Q-4803SZ
AM6Q-4805SZ
AM6Q-4812SZ
AM6Q-4815SZ
Input Voltage
(V)
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
Output
Voltage
(V)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
Output Current
max (mA)
1000
1000
500
400
1000
1200
500
400
1200
1200
500
400
1200
1200
500
400
Isolation
(VAC)
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
Max
Capacitive
Load(uF)
1000
1000
500
400
1000
1200
500
400
1200
1200
500
400
1200
1200
500
400
Efficiency
(%)
73
76
79
79
76
81
85
85
73
80
84
86
74
80
84
85
Models
Dual output
Model
AM6Q-0512DZ
AM6Q-0515DZ
AM6Q-1212DZ
AM6Q-1215DZ
AM6Q-2412DZ
AM6Q-2415DZ
AM6Q-4812DZ
AM6Q-4815DZ
Input Voltage
(V)
4.5-9
4.5-9
9-18
9-18
18-36
18-36
36-75
36-75
Output
Voltage
(V)
±12
±15
±12
±15
±12
±15
±12
±15
Output Current
max (mA)
±250
±200
±250
±200
±250
±200
±250
±200
Isolation
(VAC)
500
500
500
500
500
500
500
500
Max
Capacitive
Load(uF)
±250
±200
±250
±200
±250
±200
±250
±200
Efficiency
(%)
82
82
88
88
88
88
87
88
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
No Load Input Current
Input reflected current
Nominal
5
12
24
48
Typical
4.5-9
9-18
18-36
36-75
π (Pi) Network
20
45
20
Maximum
Units
VDC
ms
mA
mA
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3sec
Typical
500
50
500
Series AM6Q-Z
6 Watt | DC-DC Converter
Maximum
Units
VAC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Conditions
25% load on one output –
100% load on the other output
Over voltage protection
Zener Diode Clamp
Over Current Protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
FL
LL-HL
Load:0-100% unbalanced
20MHz Bandwidth
Typical
±1
±5
5
12
15
±12
±15
185
Continuous
Auto Recovery
±0.5
±1
±0.02
75
0
Maximum
6.2
15
18
±15
±18
Units
%
%
V
%
% of Vin
%
%/oC
mV p-p
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Transient recovery deviation
Conditions
Typical
Maximum
100% load
330
Derating above 60ºC
-40 to +85
-40 to +125
100
Free Air Convection
95
Nickel Coated Copper
25
1.75 x 1.10 x 0.28 inches 44.50 x 28.00 x 7.00 mm
>1.28Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C )
±3
Units
KHz
oC
oC
oC
% RH
g
%
Safety Specifications
Parameters
Standards
Designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin Single
1 -V Input
2 +V Input
3 +V Output
4 NP
5 -V Output
NP: Not Populated
Dual
-V Input
+V Input
+V Output
Common
-V Output
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Dimensions
Series AM6Q-Z
6 Watt | DC-DC Converter
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AM6Q-Z datasheet pdf
Download PDF
AM6Q-Z pdf
View PDF for Mobile


Related : Start with AM6Q- Part Numbers by
AM6Q-Z DC-DC Converter AM6Q-Z
AIMTEC
AM6Q-Z pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact