FEATURES:
Wide 4:1 Input Voltage Range
High efficiency up to 85%
1500 VDC Isolation
Low ripple & noise
Series AM6CW-NZ
6 Watt | DC-DC Converter
Operating Temperature -40ºC to +85ºC
Output Over Voltage protection
Continuous Short Circuit Protection
Models
Single output
Model
AM6CW-11005S-NZ
AM6CW-11012S-NZ
AM6CW-11015S-NZ
AM6CW-11024S-NZ
Input
Voltage (V)
40-160
40-160
40-160
40-160
Output
Voltage
(V)
5
12
15
24
Output Current
max (mA)
1200
500
400
250
Isolation
(VDC)
1500
1500
1500
1500
Max
Capacitive
Load(uF)
1000
100
100
47
Efficiency
(%)
81
83
85
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating (100ms)
No Load Input Current
Input reflected current
Nominal
110
110
Typical
40-160
Pi
2
20
Maximum
180
Units
VDC
VDC
mA
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec, <1mA
500VDC
Typical
1500
1000
Maximum
>1000
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple
Noise
Transient recovery time
Transient recovery deviation
Conditions
Full load, LL to HL
5% to 100% load
100% load
25% load step change
25% load step change
Typical
±2
110-140
Continuous
Auto-Recovery
±0.5
±1
25
100
±5
Maximum
±0.03
1
Units
%
% of Vo
% of Vin
%
%/oC
mV p-p
mV p-p
mS
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
www.aimtec.com
F 051e R13
Conditions
100% load
Derating above 71°C
Typical
300
-55 to +125
-40 to +85
Free air convection
Maximum
100
Units
KHz
oC
oC
oC
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AM6CW-NZ
6 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Humidity
95
Case material
Aluminum Alloy
Weight
14
Dimensions (L x W x H)
MTBF
1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
Maximum soldering temperature 1.5mm from case for 10 sec
300
Vibrations
5-150Hz, Displacement: 7.5mm, Acceleration: 2g
Units
% RH
g
oC
Safety Specifications
Parameters
Standards
Meets EN60950-1
EN 55022, class B (with the recommended EMC circuit)
Pin Out Specifications
Pin Single
1 -Vin
2 +Vin
3 +Vout
4 -Vout
Dimensions
Top View
25.40
(1.00)
Side View
Printed Face
Bottom View
20.32
(0.80)
3
+V Output
4
-V Output
+V -V
Input Input
12
10.16 5.08
(0.40) (0.20)
Notes: All dimensions are typical in millimeters (inches).
Case Tolerance ±0.25 (±0.01)
Pin diameter tolerance ±0.1 (±0.004)
Pin height tolerance ±0.5 (±0.02)
2.54
(0.10)
www.aimtec.com
F 051e R13
1.00
(0.39)
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Derating
Free Air Convection
71ºC
100
80
Safe Operating Area
60
40
20
0
- 40 - 20
0
20 40 60 8085 100
Ambient Temperature º C
Recommended EMC Circuit
+Vin
     ‐Vin
     
       L1
        10mH
        L1
          10mH
      CX
        0.68uF
      CX
        0.68uF
      CX
        0.68uF
    
     Y1
1nF/2KV
AM6CWNZ
Y2
1nF/2KV
Series AM6CW-NZ
6 Watt | DC-DC Converter
+Vo
    ‐Vo
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AM6CW-NZ datasheet pdf
Download PDF
AM6CW-NZ pdf
View PDF for Mobile


Related : Start with AM6CW-N Part Numbers by
AM6CW-NZ DC-DC Converter AM6CW-NZ
AIMTEC
AM6CW-NZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact