AM40E-Z Datasheet PDF - AIMTEC

www.Datasheet-PDF.com

AM40E-Z
AIMTEC

Part Number AM40E-Z
Description DC-DC Converter
Page 7 Pages


AM40E-Z datasheet pdf
Download PDF
AM40E-Z pdf
View PDF for Mobile


No Preview Available !

FEATURES:
Click on Series name for product info on aimtec.com
Series AM40E-Z
40 Watt | DC-DC Converter
Wide 2:1 Input Range
Adjustable Single Output Voltage
Undervoltage lockout
High Power Density
Efficiency up to 92%
Remote On/Off Function
Soft start
Models
Single output
Model
Input Voltage
(V)
AM40E-1203SZ
9-18
AM40E-1205SZ
9-18
AM40E-1212SZ
9-18
AM40E-1215SZ
9-18
AM40E-2403SZ
18-36
AM40E-2405SZ
18-36
AM40E-2412SZ
18-36
AM40E-2415SZ
18-36
AM40E-4803SZ
36-75
AM40E-4805SZ
36-75
AM40E-4812SZ
36-75
AM40E-4815SZ
36-75
Add suffix “-K” for optional heat sink
Output Voltage
(V)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
Output Current
max (A)
8
8
3.33
2.67
8
8
3.33
2.67
8
8
3.33
2.67
Maximum
Capacitive load
(µF)
21800
13600
2300
1500
21800
13600
2300
1500
21800
13600
2300
1500
Efficiency
(%)
90
91
91
91
91
92
91
92
91
92
91
92
Models
Dual output
Model
Input Voltage
(V)
Output Voltage Output Current
(V) max (A)
Maximum
Capacitive load
(µF)
Efficiency
(%)
AM40E-1212DZ
9-18
±12
±1.67
±1200
91
AM40E-1215DZ
9-18
±15
±1.33
±750
92
AM40E-2412DZ
18-36
±12
±1.67
±1200
91
AM40E-2415DZ
18-36
±15
±1.33
±750
92
AM40E-4812DZ
36-75
±12
±1.67
±1200
92
AM40E-4815DZ
36-75
±15
±1.33
±750
92
Add suffix “-K” for optional heat sink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
Under voltage lockout
Input Reflected Ripple Current
www.aimtec.com
F 051e R12.D
Nominal
Typical
Maximum
Units
12 9-18
24 18-36
VDC
48 36-75
π (Pi) Network
30 ms
12 25
24 50 VDC
48 100
1s
ON: 3 ~12VDC or open circuit ; OFF – 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
(OFF idle current: 5mA Typical)
12V ON/OFF
8.6 / 7.9
24V ON/OFF
17.8 / 16
VDC
48V ON/OFF
33.5 / 30.5
20 mA p-p
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Isolation Specifications
Parameters
Tested I/O voltage
Case/Input and Output
Resistance
Capacitance
Conditions
3 sec
3 sec
Typical
1600
<1000
1000
Series AM40E-Z
40 Watt | DC-DC Converter
Rated
1600
Units
VDC
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise (20MHz Bandwidth)
Voltage adjustment range (single)
Minimum Load Current
Conditions
25% load on one output
100% load on second load
HL-LL
0% to 100% load
0% to 100% load
3.3Vout/5Vout
other models
Typical
±1
±5
Zener diode clamp
130
Continuous
Auto-Recovery
±0.5
±0.5
±1
±0.02
100
150
0
Maximum
±10
Units
%
%
% of Iout
%
%
%
%/oC
mV p-p
%
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
Maximum
100% load
270
See derating chart
-40 to +71
-40 to +125
105
2.5
Free Air Convection
95
Nickel coated Copper
32
2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm
>328,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours
1.5mm from case for 10 sec
260
250
±3
Units
KHz
oC
oC
oC
%/ oC
% RH
g
oC
µS
%
Safety Specifications
Parameters
Agency Approval
Safety
CE
EN55022: 2006 + A1:2007, Class B
IEC61000-3-2:2006+A2:2009
IEC61000-3-3:2008
EN55024:1998 + A1:2001 + A2:2003
IEC61000-4-2: 2008
IEC61000-4-3:2006+A1: 2007
IEC61000-4-4:2004
IEC61000-4-5:2005
IEC61000-4-6:2008
IEC61000-4-8:2009
NOTE: also designed to meet IEC 60950-1:2001
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
2 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Pin Out Specifications
Pin Single
Dual
1 + V Input
+ V Input
2 - V Input
- V Input
3 On/Off Control On/Off Control
4 + V Output + V Output
5 -V Output
Common
6 Trim
- V Output
Dimensions
Series AM40E-Z
40 Watt | DC-DC Converter
Dimensions with Optional Heatsink
Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to
total mass (42.2g). Thermal impedance of converter is: with heat sink 10Ԩ/W and 12Ԩ/W without heat sink.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
3 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Trimming
Derating
Series AM40E-Z
40 Watt | DC-DC Converter
Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number)
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
4 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AM40E-Z datasheet pdf
Download PDF
AM40E-Z pdf
View PDF for Mobile


Related : Start with AM40E- Part Numbers by
AM40E-Z DC-DC Converter AM40E-Z
AIMTEC
AM40E-Z pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact