FEATURES:
SMD package
Wide (2:1) input range
1500VDC isolation
Continuous short circuit protection
Series AM3LV-NZ
3 Watt | DC-DC Converter
Operating temperature: -40°C to +85°C
Regulated Output
MTBF>1,000,000 hours
Models
Single output
Model
AM3LV-1205S-NZ
AM3LV-1212S-NZ
AM3LV-1215S-NZ
AM3LV-2405S-NZ
AM3LV-2412S-NZ
AM3LV-2415S-NZ
AM3LV-4805S-NZ
AM3LV-4812S-NZ
AM3LV-4815S-NZ
Input Voltage(V)
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
Output Voltage
(V)
5
12
15
5
12
15
5
12
15
Output Current
max(mA)
600
250
200
600
250
200
600
250
200
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
Efficiency
(%)
75
77
79
76
81
80
77
80
80
Models
Dual output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
AM3LV-1205D-NZ
9-18
±5
±300
1500
76
AM3LV-1212D-NZ
9-18
±12
±125
1500
80
AM3LV-1215D-NZ
9-18
±15
±100
1500
80
AM3LV-2405D-NZ
18-36
±5
±300
1500
76
AM3LV-2412D-NZ
18-36
±12
±125
1500
80
AM3LV-2415D-NZ
18-36
±15
±100
1500
80
NOTE: Unless otherwise specified, all specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load.
Input Specifications
Parameters
Voltage range
Absolute Maximum Rating
Peak Input Voltage time
Input Filter
Nominal
12
24
48
12
24
48
Typical
9-18
18-36
36-72
Pi (π)
Maximum
25
50
100
100
Units
VDC
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec
At 500 Vdc
Input to Output
Typical
1000
1000
Rated
1500
Units
VDC
MOhm
pF
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Series AM3LV-NZ
3 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±1 %
Short Circuit protection
Continuous
Short circuit restart
Auto-Recovery
Line voltage regulation (Single)
From Low in to High In
±0.2
%
Load voltage regulation (Single)
From 5% to 100% load
±0.2
%
Load voltage regulation (Dual)
From 10% to 100% load
Unbalanced load
±5
%
Transient Recovery Time
25% Load Step Change
0.5
m sec
Transient Response Deviation
Temperature coefficient
25% Load Step Change
±2
±0.03
%
%/oC
Ripple & Noise *
20MHz Bandwidth
100
mVp-p
* Converters are designed to operate with a minimum load of 5%. If converter is operated with a load less than 10% the ripple will increase.
General Specifications
Parameters
Switching frequency
Operating temperature
Temperature Rise
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
.
Conditions
Typical
Maximum
100% load
Full load, 25oC
350
-40 to +85oC
25oC
-55 to +125oC
100
Above 71ºC on dual output
models, others above 85ºC
See Chart
Free Air Convection
95
Epoxy resin (UL94-V0 rated)
5.2
0.94 x 0.54 x 0.34inches 23.86 x 13.70 x 8.50 mm
>1,000,000 hours(MIL-HDBK -217F, Ground Benign, t=+25ºC)
1.5mm from case for 10 seconds
260
Units
KHz
oC
oC
oC
% RH
g
oC
Pin Out Specifications
Pin Single
Dual
1 - Vin
- Vin
7 NC
NC
8 NC
Common
9 +Vout
+Vout
10 - Vout
-Vout
16 + Vin
+ Vin
NC – not connected
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Dimensions
Series AM3LV-NZ
3 Watt | DC-DC Converter
Recommended Circuit
External Capacitor Value
Dual Output
Vout (VDC)
±5
±12
±15
Cin
100
10 - 47
10 - 47
Cout (uF)
10
10
10
+ Vin
Cin +
- Vin
Dual Output
Cout +
DC DC Cout +
+Vout
Common
-Vout
External Capacitor Value
Single Output
Vout (VDC)
12
24
48
Cin
100
10 - 47
10 - 47
Cout (uF)
10
10
10
+ Vin
Cin +
Single Output
+Vout
DC DC Cout +
-Vout
- Vin
All the AM3LV-Z Series have been tested with the above recommended test circuit. This series should be tested under load.
If it is necessary to further decrease the input/output ripple, the value of the filter capacitor can be increased; a capacitor with a low ESR
should be used. Excessive filter capacitance can cause start up problems with the converter.
In general, the recommended capacitance values are:
Cin: 12V input100μF, 24V&48Vinput 10μF~47μFCout: 10μF/100mA
Refer to table for maximum capacitor values
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



No Preview Available !

Recommended Circuit (Single Output Models)
+ Vin FUSE
LDM2
Single Output
Series AM3LV-NZ
3 Watt | DC-DC Converter
+Vout
MOV
C3 +
TVS
DC
- Vin
Optional Surge
Circuit
Model MOV TVS
C3
12 Vin
- SMCJ28A
24 Vin
10D560 SMCJ48A
48 Vin
10D101 SMCJ90A
Note: Fuse is user selectable
680µF / 25V
120µF / 50V
120µF / 100V
LDM2
56 µH
56 µH
56 µH
DC
- Vout
Derating
Dual Output
Free Air Convection
100
80
Safe Operating Area
60
40
71ºC
20
0
- 40 - 20
0
20 40 60 80 85 100
Ambient Temperature º C
Single Output
Free Air Convection
85ºC
100
80
60
Safe Operating Area
40
20
0
- 40 - 20
0
20 40 60 80 85 100105
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only



AM3LV-NZ datasheet pdf
Download PDF
AM3LV-NZ pdf
View PDF for Mobile


Related : Start with AM3LV-N Part Numbers by
AM3LV-NZ DC-DC Converter AM3LV-NZ
AIMTEC
AM3LV-NZ pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact