ACS704ELC-015 Datasheet PDF - Allegro MicroSystems

www.Datasheet-PDF.com

ACS704ELC-015
Allegro MicroSystems

Part Number ACS704ELC-015
Description Fully Integrated / Hall Effect-Based Linear Current Sensor
Page 20 Pages


ACS704ELC-015 datasheet pdf
Download PDF
ACS704ELC-015 pdf
View PDF for Mobile

No Preview Available !

ACS704ELC-015
Fully Integrated, Hall Effect-Based Linear Current Sensor
with Voltage Isolation and a Low-Resistance Current Conductor
Not for New Design
These parts are in production but have been determined to be
NOT FOR NEW DESIGN. This classification indicates that sale of
this device is currently restricted to existing customer applications.
The device should not be purchased for new design applications
because obsolescence in the near future is probable. Samples are no
longer available.
Date of status change: October 31, 2006
Recommended Substitutions:www.DataSheet4U.com
For existing customer transition, and for new customers or new appli-
cations, refer to the ACS712.
NOTE: For detailed information on purchasing options, contact your
local Allegro field applications engineer or sales representative.
Allegro MicroSystems, Inc. reserves the right to make, from time to time, revisions to the anticipated product life cycle plan
for a product to accommodate changes in production capabilities, alternative product availabilities, or market demand. The
information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no respon-
sibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.



No Preview Available !

ACS704ELC-015
Fully Integrated, Hall Effect-Based Linear Current Sensor
with Voltage Isolation and a Low-Resistance Current Conductor
Package LC
Pin 1: IP+
Pin 2: IP+
Pin 3: IP–
Pin 4: IP–
Pin 8: VCC
Pin 7: VOUT
Pin 6: N.C.
Pin 5: GND
Pins 6 and 7 are internally connected in shipping
product. For compatibility with future devices,
leave pin 6 floating.
Nominal Operating Temperature, TA
Range E............................................ –40 to 85ºC
Overcurrent Transient Tolerance*, IP ................ 60 A
*100 total pulses, 250 ms duration each, applied at a rate of
1 pulse every 100 seconds.
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VCC .......................................... 16 V
Reverse Supply Voltage, VRCC ........................ –16 V
Output Voltage, VOUT ........................................ 16 V
Reverse Output Voltage, VROUT...................... –0.1 V
Output Current Source, IOUT(Source) ................. 3 mA
Output Current Sink, IOUT(Sink).......................10 mA
Operating Temperature,
Maximum Junction, TJ(max)....................... 165°C
Storage Temperature, TS ...................... –65 to 170°C
TÜV America
Certificate Number:
U8V 04 12 54214 005
The Allegro ACS704 family of current sensors provides economical and
precise solutions for current sensing in industrial, automotive, commercial, and
communications systems. The device package allows for easy implementation
by the customer. Typical applications include motor control, load detection and
management, switched-mode power supplies, and overcurrent fault protection.
The device consists of a precision, low-offset linear Hall sensor circuit with
a copper conduction path located near the surface of the die. Applied current
flowing through this copper conduction path generates a magnetic field which is
sensed by the integrated Hall IC and converted into a proportional voltage. Device
accuracy is optimized through the close proximity of the magnetic signal to the
Hall transducer. A precise, proportional voltage is provided by the low-offset,
chopper-stabilized BiCMOS Hall IC, which is programmed for accuracy at the
factory.
The output of the device has a positive slope (>VCC / 2) when an increasing
current flows through the primary copper conduction path (from pins 1 and 2, to
pins 3 and 4), which is the path used for current sensing. The internal resistance of
this conductive path is typically 1.5 mΩ, providing low power loss. The thickness
of the copper conductor allows survival of the device at up to 3× overcurrent
conditions. The terminals of the conductive path are electrically isolated from the
sensor leads (pins 5 through 8). This allows the ACS704 family of sensors to be
used in applications requiring electrical isolation without the use of opto-isolators
or other costly isolation techniques.
The ACS704 is provided in a small, surface mount SOIC8 package. The leadframe
is plated with 100% matte tin, which is compatible with standard lead (Pb) free
printed circuit board assembly processes. Internally, the flip-chip uses high-tem-
perature Pb-based solder balls, currently exempt from RoHS. The device is fully
calibrated prior to shipment from the factory.
Features and Benefits
• Small footprint, low-profile SOIC8 package
• 1.5 mΩ internal conductor resistance
• Excellent replacement for sense resistors
• 800 VRMS minimum isolation voltage between pins 1-4 and 5-8
• 4.5 to 5.5 V, single supply operation
• 50 kHz bandwidth
• 100 mV/A output sensitivity and 20 A dynamic range
• Output voltage proportional to ac and dc currents
• Factory-trimmed for accuracy
• Extremely stable output offset voltage
• Near-zero magnetic hysteresis
• Ratiometric output from supply voltage
Use the following complete part number when ordering:
Part Number
ACS704ELC-015
Package
SOIC8 surface mount
ACS704ELC015-DS, Rev. 6
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com



No Preview Available !

ACS704ELC-015
Functional Block Diagram
Pin 3 Pin 4
IP– IP–
VCC
Pin 8
+5 V
Voltage
Regulator
To all subcircuits
Amp
Out
VOUT
Pin 7
A
N.C.
Pin 6
Gain
Temperature
Coefficient
Trim Control
Offset
0.1 μF
IP+ IP+
Pin 1 Pin 2
GND
Pin 5
A Pins 6 and 7 are internally connected in shipping product.
For compatibility with future devices, leave pin 6 floating.
ACS704ELC015-DS, Rev. 6
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
2



No Preview Available !

ACS704ELC-015
ELECTRICAL CHARACTERISTICS, over operating ambient temperature range unless otherwise stated
Characteristic
Symbol
Test Conditions
Min.
Primary Sensed Current1
Supply Voltage
IP
VCC
–15
4.5
Supply Current
ICC VCC = 5.0 V, output open
5
Output Resistance
Output Capacitance Load
ROUT
CLOAD
IOUT = 1.2 mA
VOUT to GND
Output Resistive Load
RLOAD
VOUT to GND
4.7
Primary Conductor Resistance
RPRIMARY TA = 25°C
Isolation Voltage
VISO
Pins 1-4 and 5-8; 60 Hz, 1 minute
800
PERFORMANCE CHARACTERISTICS, TA = –40°C to 85°C, VCC = 5 V unless otherwise specified
Propagation Time
tPROP
IP =±15 A, TA = 25°C
Response Time
tRESPONSE IP =±15 A, TA = 25°C
Rise Time
tr IP =±15 A, TA = 25°C
Frequency Bandwidth
f
–3 dB, TA = 25°C; IP is 10 A peak-to-
peak; no external filter
Typ.
5.0
8
1
1.5
1200
4
8
9
50
Max.
15
5.5
10
2
10
Units
A
V
mA
Ω
nF
kΩ
mΩ
V
μs
μs
μs
kHz
Sensitivity
Noise
Sens
Over full range of IP,
IP applied for 5 ms; TA = 25°C
Over full range of IP,
IP applied for 5 ms; TA = –40 to 85°C
94
100
– mV/A
106 mV/A
VNOISE
Peak-to-peak, TA = 25°C,
no external filter
Root Mean Square, TA = 25°C,
no external filter
– 70
– 12.5
mV
mV
Linearity
ELIN
Over full range of IP,
IP applied for 5 ms; TA = –40 to 85°C
±1 ±3.5 %
Symmetry
ESYM
Over full range of IP,
IP applied for 5 ms; TA = –40 to 85°C
98
100
102
%
Zero Current Output Voltage
VOUT(Q) IP = 0 A, TA = 25°C
– VCC / 2
V
Electrical Offset Voltage
VOE
IP = 0 A, TA = 25°C
IP = 0 A, TA = –40 to 85°C
–15 –
–50 –
15 mV
50 mV
Magnetic Offset Error
IERROM
IP = 0 A, after excursion of 15 A;
TA = –40 to 85°C
±0.01
±0.05
A
IP =±15 A, IP applied for 5 ms;
TA = 25°C
– ±1.5
%
Total Output Error2
ETOT
IP = ±10 A, IP applied for 5 ms;
TA = –40 to 85°C
– – ±6.0 %
IP = ±15 A, IP applied for 5 ms;
TA = –40 to 85°C
– – ±8.4 %
1Device may be operated at higher primary current, IP, and Ambient Temperature, TA, levels, provided that the Maximum Junction Temperature, TJ(max),
is not exceeded.
2Percentage of IP, with IP = 15 A; Output filtered. Up to a 2.0% shift in ETOT may be observed at end-of-life for this device.
ACS704ELC015-DS, Rev. 6
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
3



ACS704ELC-015 datasheet pdf
Download PDF
ACS704ELC-015 pdf
View PDF for Mobile


Related : Start with ACS704ELC-01 Part Numbers by
ACS704ELC-015 Fully Integrated / Hall Effect-Based Linear Current Sensor ACS704ELC-015
Allegro MicroSystems
ACS704ELC-015 pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact